18401 W MALDEN ST 91325

Certificate Information: 18401 W MALDEN ST 91325

Application / Permit
20016-10000-14595
Plan Check / Job No.
B20LA10865
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT STORY RETROFIT PER LAMC DIV. 93.- INSTALL (1) ORDINARY MOMENT FRAME AND (5) STEEL SPECIAL CANTILEVER COLUMNS.
Permit Issued
Issued on 11/13/2020
Issuing Office
Current Status
CofC Issued on 1/19/2021

Permit Application Status History

Submitted 6/19/2020 APPLICANT
Assigned to Plan Check Engineer 7/15/2020 YOUNG KIM
Corrections Issued 7/21/2020 YOUNG KIM
Quality Review Completed 7/22/2020 HANS SANTIAGO
Building Plans Picked Up 7/28/2020 APPLICANT
Applicant returned to address corrections 10/6/2020 YOUNG KIM
Applicant returned to address corrections 10/7/2020 YOUNG KIM
Applicant returned to address corrections 10/14/2020 YOUNG KIM
Plan Check Approved 11/13/2020 YOUNG KIM
Issued 11/13/2020 APPLICANT
OK for CofC 1/13/2021 DANIEL VARNUM
CofC Issued 1/19/2021 JEFFREY DURAN

Permit Application Clearance Information

Tenant Habitability Plan Cleared 9/8/2020 STEVEN HOFSTAD

Contact Information

Contractor Core Contractors Llc; Lic. No.: 1038618-B 9800D TOPANGA CANYON BLVD   SUITE 324    CHATSWORTH, CA 91311
Engineer Deihimi,, Amir Hossein; Lic. No.: C78194 23172 PLAZA POINTE DR STE 145      LAGUNA HILLS, CA 92653

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 11/25/2020 Not Ready for Inspection DANIEL VARNUM
Floor/Roof Diaphrgm/Shear Wall 11/25/2020 Not Ready for Inspection DANIEL VARNUM
Pre-Inspection 11/25/2020 Partial Inspection DANIEL VARNUM
Deputy Drilled-In Anchors 12/3/2020 Conditional Approval DANIEL VARNUM
Deputy Steel/Welding 12/9/2020 Conditional Approval DANIEL VARNUM
Excavation/Setback/Form/Re-Bar 12/11/2020 Not Ready for Inspection DANIEL VARNUM
Floor/Roof Diaphrgm/Shear Wall 12/11/2020 Not Ready for Inspection DANIEL VARNUM
Footing/Foundation/Slab 12/11/2020 Not Ready for Inspection DANIEL VARNUM
Structural Steel Frame 12/11/2020 Not Ready for Inspection DANIEL VARNUM
Excavation/Setback/Form/Re-Bar 12/17/2020 Approved DANIEL VARNUM
Floor/Roof Diaphrgm/Shear Wall 12/17/2020 Approved DANIEL VARNUM
Footing/Foundation/Slab 12/17/2020 Approved DANIEL VARNUM
Structural Steel Frame 12/17/2020 Approved DANIEL VARNUM
Interior/Exterior Lathing 12/24/2020 Approved DANIEL VARNUM
Final 1/8/2021 Not Ready for Inspection DANIEL VARNUM
SGSOV-Seismic Gas S/O Valve 1/8/2021 SGSOV Not Ready DANIEL VARNUM
Smoke Detectors 1/8/2021 Not Ready for Inspection DANIEL VARNUM
Final 1/13/2021 OK for CofC DANIEL VARNUM
SGSOV-Seismic Gas S/O Valve 1/13/2021 SGSOV Approved DANIEL VARNUM
Smoke Detectors 1/13/2021 Approved DANIEL VARNUM