18401 W MALDEN ST 91325
Certificate Information: 18401 W MALDEN ST 91325
- Application / Permit
- 20016-10000-14595
- Plan Check / Job No.
- B20LA10865
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT PER LAMC DIV. 93.- INSTALL (1) ORDINARY MOMENT FRAME AND (5) STEEL SPECIAL CANTILEVER COLUMNS.
- Permit Issued
- Issued on 11/13/2020
- Issuing Office
- Current Status
- CofC Issued on 1/19/2021
Permit Application Status History
| Submitted | 6/19/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/15/2020 | YOUNG KIM |
| Corrections Issued | 7/21/2020 | YOUNG KIM |
| Quality Review Completed | 7/22/2020 | HANS SANTIAGO |
| Building Plans Picked Up | 7/28/2020 | APPLICANT |
| Applicant returned to address corrections | 10/6/2020 | YOUNG KIM |
| Applicant returned to address corrections | 10/7/2020 | YOUNG KIM |
| Applicant returned to address corrections | 10/14/2020 | YOUNG KIM |
| Plan Check Approved | 11/13/2020 | YOUNG KIM |
| Issued | 11/13/2020 | APPLICANT |
| OK for CofC | 1/13/2021 | DANIEL VARNUM |
| CofC Issued | 1/19/2021 | JEFFREY DURAN |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 9/8/2020 | STEVEN HOFSTAD |
Contact Information
| Contractor | Core Contractors Llc; Lic. No.: 1038618-B | 9800D TOPANGA CANYON BLVD SUITE 324 CHATSWORTH, CA 91311 |
| Engineer | Deihimi,, Amir Hossein; Lic. No.: C78194 | 23172 PLAZA POINTE DR STE 145 LAGUNA HILLS, CA 92653 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 11/25/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Floor/Roof Diaphrgm/Shear Wall | 11/25/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Pre-Inspection | 11/25/2020 | Partial Inspection | DANIEL VARNUM |
| Deputy Drilled-In Anchors | 12/3/2020 | Conditional Approval | DANIEL VARNUM |
| Deputy Steel/Welding | 12/9/2020 | Conditional Approval | DANIEL VARNUM |
| Excavation/Setback/Form/Re-Bar | 12/11/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Floor/Roof Diaphrgm/Shear Wall | 12/11/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Footing/Foundation/Slab | 12/11/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Structural Steel Frame | 12/11/2020 | Not Ready for Inspection | DANIEL VARNUM |
| Excavation/Setback/Form/Re-Bar | 12/17/2020 | Approved | DANIEL VARNUM |
| Floor/Roof Diaphrgm/Shear Wall | 12/17/2020 | Approved | DANIEL VARNUM |
| Footing/Foundation/Slab | 12/17/2020 | Approved | DANIEL VARNUM |
| Structural Steel Frame | 12/17/2020 | Approved | DANIEL VARNUM |
| Interior/Exterior Lathing | 12/24/2020 | Approved | DANIEL VARNUM |
| Final | 1/8/2021 | Not Ready for Inspection | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 1/8/2021 | SGSOV Not Ready | DANIEL VARNUM |
| Smoke Detectors | 1/8/2021 | Not Ready for Inspection | DANIEL VARNUM |
| Final | 1/13/2021 | OK for CofC | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 1/13/2021 | SGSOV Approved | DANIEL VARNUM |
| Smoke Detectors | 1/13/2021 | Approved | DANIEL VARNUM |