7818 W MANCHESTER AVE 90293
Certificate Information: 7818 W MANCHESTER AVE 90293
- Application / Permit
- 20016-10000-11042
- Plan Check / Job No.
- B20LA08242
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- EPLAN 4597 - Soft-Story seismic retrofit per LABC Chapter 93: INSTALL STEEL CANTILEVER COLUMN.
- Permit Issued
- Issued on 11/25/2020
- Issuing Office
- Current Status
- CofC Issued on 5/4/2021
Permit Application Status History
| Submitted | 5/8/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 6/3/2020 | VARAND SARKISIAN |
| Corrections Issued | 6/11/2020 | VARAND SARKISIAN |
| Quality Review Completed | 6/12/2020 | SAI KHUM |
| Plan Check Approved | 8/20/2020 | VARAND SARKISIAN |
| Issued | 11/25/2020 | APPLICANT |
| OK for CofC | 5/3/2021 | GRANT WOODS |
| CofC Issued | 5/4/2021 | TED RIES |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 11/24/2020 | ISMAEL HERNANDEZ |
Contact Information
| Contractor | Cal - Quake Construction Inc; Lic. No.: 759817-B | 636 NORTH FORMOSA AVENUE LOS ANGELES, CA 90036 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 743 S SIERRA VISTA AVE C ALHAMBRA, CA 91801 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 1/7/2021 | Approved | GRANT WOODS |
| Deputy Drilled-In Anchors | 1/13/2021 | Approved | GRANT WOODS |
| Deputy Steel/Welding | 1/13/2021 | Approved | GRANT WOODS |
| Excavation/Setback/Form/Re-Bar | 1/13/2021 | Approved | GRANT WOODS |
| Structural Steel Frame | 1/14/2021 | Not Ready for Inspection | GRANT WOODS |
| Wood Frame | 1/14/2021 | Not Ready for Inspection | GRANT WOODS |
| Deputy Reinf. Concrete | 1/15/2021 | Approved | GRANT WOODS |
| Structural Steel Frame | 1/15/2021 | Approved | GRANT WOODS |
| Wood Frame | 1/15/2021 | Approved | GRANT WOODS |
| Drywall Nailing | 2/1/2021 | Approved | GRANT WOODS |
| Final | 4/7/2021 | Corrections Issued | GRANT WOODS |
| METHANE-Final | 4/7/2021 | Approved | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 4/7/2021 | SGSOV Not Ready | GRANT WOODS |
| Smoke Detectors | 4/7/2021 | Not Ready for Inspection | GRANT WOODS |
| Final | 5/3/2021 | OK for CofC | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 5/3/2021 | SGSOV Approved | GRANT WOODS |
| Smoke Detectors | 5/3/2021 | Approved | GRANT WOODS |