12621 W CASWELL AVE 90066

Certificate Information: 12621 W CASWELL AVE 90066

Application / Permit
20016-10000-08182
Plan Check / Job No.
B20LA05764
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
EPLAN 2058 - Soft-Story seismic retrofit per LABC Chapter 93: INSTALL STEEL CANTILEVER COLUMNS AND PLYWOOD SHEAR WALLS.
Permit Issued
Issued on 11/4/2020
Issuing Office
Current Status
CofC Issued on 3/22/2021

Permit Application Status History

Submitted 3/25/2020 APPLICANT
Assigned to Plan Check Engineer 4/15/2020 VARAND SARKISIAN
Corrections Issued 4/22/2020 VARAND SARKISIAN
Quality Review Completed 4/24/2020 SAI KHUM
Plan Check Approved 5/12/2020 VARAND SARKISIAN
Issued 11/4/2020 APPLICANT
OK for CofC 3/18/2021 GRANT WOODS
CofC Issued 3/22/2021 TED RIES

Permit Application Clearance Information

Tenant Habitability Plan Cleared 7/20/2020 STEVEN HOFSTAD

Contact Information

Contractor G Tech Enterprise; Lic. No.: 869746-B 19142 HAYNES STREET UNIT 8      RESEDA, CA 91335
Engineer Acciani,, Mark; Lic. No.: NA83929       ,

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 11/20/2020 Not Ready for Inspection GRANT WOODS
Pre-Inspection 11/24/2020 Approved GRANT WOODS
Deputy Steel/Welding 12/11/2020 Conditional Approval GRANT WOODS
Deputy Drilled-In Anchors 1/11/2021 Approved GRANT WOODS
Footing/Foundation/Slab 1/11/2021 Not Ready for Inspection GRANT WOODS
Footing/Foundation/Slab 1/15/2021 Approved GRANT WOODS
Deputy Reinf. Concrete 1/19/2021 Conditional Approval GRANT WOODS
Deputy Wood Construction 1/22/2021 Conditional Approval GRANT WOODS
Wood Frame 2/11/2021 Approved GRANT WOODS
Interior/Exterior Lathing 2/18/2021 Approved GRANT WOODS
SGSOV-Seismic Gas S/O Valve 3/9/2021 SGSOV Approved GRANT WOODS
Final 3/18/2021 OK for CofC GRANT WOODS
Smoke Detectors 3/18/2021 Approved GRANT WOODS