1907 S MALCOLM AVE 90025

Certificate Information: 1907 S MALCOLM AVE 90025

Application / Permit
20016-10000-08097
Plan Check / Job No.
B20LA05739
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Soft-Story seismic retrofit per LABC Chapter 93: INSTALL (2) STEEL SPECIAL CANTILEVER COLUMNS.
Permit Issued
Issued on 8/5/2020
Issuing Office
Current Status
CofC Issued on 10/19/2020

Permit Application Status History

Submitted 3/23/2020 APPLICANT
Assigned to Plan Check Engineer 4/15/2020 DANIEL SANJUAN
Corrections Issued 4/22/2020 DANIEL SANJUAN
Quality Review Completed 4/23/2020 HANS SANTIAGO
Plan Check Approved 5/27/2020 DANIEL SANJUAN
Issued 8/5/2020 APPLICANT
OK for CofC 9/10/2020 PAUL DAVIDSON
CofC Issued 10/19/2020 TED RIES

Permit Application Clearance Information

Tenant Habitability Plan Cleared 7/6/2020 STEVEN HOFSTAD

Contact Information

Contractor Sinai Construction; Lic. No.: 1035535-B 5142 VENICE BLVD      LOS ANGELES, CA 90019
Engineer Zargari,, Ramin; Lic. No.: S4119 5010 N PARKWAY CALABASAS 202      CALABASAS, CA 91302

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 8/21/2020 Approved SORIN CIRSTOIU
Deputy Drilled-In Anchors 8/31/2020 Conditional Approval PAUL DAVIDSON
Deputy Steel/Welding 8/31/2020 Conditional Approval PAUL DAVIDSON
Excavation/Setback/Form/Re-Bar 9/1/2020 Not Ready for Inspection PAUL DAVIDSON
Footing/Foundation/Slab 9/1/2020 Not Ready for Inspection PAUL DAVIDSON
Structural Steel Frame 9/1/2020 Not Ready for Inspection PAUL DAVIDSON
Wood Frame 9/1/2020 Not Ready for Inspection PAUL DAVIDSON
Excavation/Setback/Form/Re-Bar 9/2/2020 Approved GRANT WOODS
Footing/Foundation/Slab 9/2/2020 Approved GRANT WOODS
Structural Steel Frame 9/2/2020 Approved GRANT WOODS
Wood Frame 9/2/2020 Approved GRANT WOODS
Interior/Exterior Lathing 9/4/2020 Approved PAUL DAVIDSON
Final 9/10/2020 OK for CofC PAUL DAVIDSON
METHANE-Final 9/10/2020 Approved PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 9/10/2020 SGSOV Approved PAUL DAVIDSON
Smoke Detectors 9/10/2020 Approved PAUL DAVIDSON