1415 S SALTAIR AVE 90025

Certificate Information: 1415 S SALTAIR AVE 90025

Application / Permit
20016-10000-03383
Plan Check / Job No.
B20LA02204
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
EPLAN 1826 - Soft-Story seismic retrofit per LABC Chapter 93: INSTALL STEEL CANTILEVER COLUMN.
Permit Issued
Issued on 11/2/2022
Issuing Office
Current Status
CofC Issued on 2/23/2023

Permit Application Status History

Submitted 2/5/2020 APPLICANT
Assigned to Plan Check Engineer 2/26/2020 VARAND SARKISIAN
Corrections Issued 3/3/2020 VARAND SARKISIAN
Quality Review Completed 3/8/2020 HANS SANTIAGO
Plan Check Approved 6/23/2020 VARAND SARKISIAN
Issued 11/2/2022 APPLICANT
OK for CofC 2/16/2023 PAUL DAVIDSON
CofC Issued 2/23/2023 HENRY BAGHDASSARIAN

Permit Application Clearance Information

Tenant Habitability Plan Cleared 10/18/2022 ISMAEL HERNANDEZ

Contact Information

Contractor American Retrofitters Corp; Lic. No.: 1020382-B       ,
Engineer Vartanian,, Albert; Lic. No.: C39989 PO BOX 857      VERDUGO CITY, CA 91046

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 11/22/2022 Approved DAVID TSAU
Deputy Steel/Welding 12/12/2022 Conditional Approval GRANT WOODS
Deputy Drilled-In Anchors 12/20/2022 Approved GRANT WOODS
Deputy Reinf. Concrete 12/20/2022 Approved GRANT WOODS
Footing/Foundation/Slab 12/20/2022 Approved GRANT WOODS
Structural Steel Frame 12/20/2022 Approved GRANT WOODS
Wood Frame 12/20/2022 Approved GRANT WOODS
Deputy Reinf. Concrete 12/22/2022 Approved GRANT WOODS
Interior/Exterior Lathing 1/31/2023 Approved SHAVONNE ESPINOZA
Final 2/16/2023 OK for CofC PAUL DAVIDSON
SGSOV-Seismic Gas S/O Valve 2/16/2023 SGSOV Approved PAUL DAVIDSON
Smoke Detectors 2/16/2023 Approved PAUL DAVIDSON