1972 N KENMORE AVE 90027
Certificate Information: 1972 N KENMORE AVE 90027
- Application / Permit
- 20016-10000-01801
- Plan Check / Job No.
- B20LA01109
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH. 93. INSTALL (1) (N) SPECIAL CANTILEVER COLUMN SYSTEM
- Permit Issued
- Issued on 4/1/2021
- Issuing Office
- Current Status
- CofC Issued on 5/14/2021
Permit Application Status History
| Submitted | 1/22/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 2/5/2020 | JESSE VIDUYA |
| Corrections Issued | 2/13/2020 | JESSE VIDUYA |
| Quality Review Completed | 2/19/2020 | SAI KHUM |
| Building Plans Picked Up | 3/4/2020 | APPLICANT |
| Plan Check Approved | 4/2/2020 | JESSE VIDUYA |
| Issued | 4/1/2021 | APPLICANT |
| OK for CofC | 5/11/2021 | MARK FERRARI |
| CofC Issued | 5/14/2021 | ERNESTO CORRAL |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 3/24/2021 | RICARDO BOHORQUEZ |
Contact Information
| Contractor | K N D Construction Inc; Lic. No.: 969756-B | 145 S GLENOAKS BLVD #204 BURBANK, CA 91502 |
| Engineer | , ; Lic. No.: C89551 | GLENDALE, CA 91208 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 4/8/2021 | Approved | MARK FERRARI |
| Deputy Drilled-In Anchors | 4/19/2021 | Conditional Approval | FRED WOHLFARTH |
| Deputy Reinf. Concrete | 4/19/2021 | Conditional Approval | FRED WOHLFARTH |
| Deputy Steel/Welding | 4/20/2021 | Conditional Approval | FRED WOHLFARTH |
| Footing/Foundation/Slab | 4/20/2021 | Approved | JONATHAN QUACH |
| Structural Steel Frame | 4/20/2021 | Approved | JONATHAN QUACH |
| Wood Frame | 4/20/2021 | Approved | JONATHAN QUACH |
| Deputy Reinf. Concrete | 4/21/2021 | Conditional Approval | FRED WOHLFARTH |
| Interior/Exterior Lathing | 5/3/2021 | Approved | JONATHAN QUACH |
| Final | 5/11/2021 | OK for CofC | MARK FERRARI |
| SGSOV-Seismic Gas S/O Valve | 5/11/2021 | SGSOV Approved | MARK FERRARI |
| Smoke Detectors | 5/11/2021 | Approved | MARK FERRARI |