3745 S BENTLEY AVE 90034
Certificate Information: 3745 S BENTLEY AVE 90034
- Application / Permit
- 20016-10000-01729
- Plan Check / Job No.
- B20LA01060
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH. 93. INSTALL WOOD SHEAR WALLS AT ONE (1) LOCATION AT SOUTH SIDE; TWO (2) LOCATIONS AT NORTH SIDE AND WEST SIDE CORNER.
- Permit Issued
- Issued on 3/14/2022
- Issuing Office
- Metro
- Current Status
- Issued on 3/14/2022
Permit Application Status History
| Submitted | 1/21/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 2/5/2020 | BIDYUT RATH |
| Corrections Issued | 2/13/2020 | BIDYUT RATH |
| Quality Review Completed | 2/19/2020 | SAI KHUM |
| Building Plans Picked Up | 2/21/2020 | APPLICANT |
| Applicant returned to address corrections | 2/8/2022 | BIDYUT RATH |
| Applicant returned to address corrections | 2/28/2022 | BIDYUT RATH |
| Plan Check Approved | 3/8/2022 | BIDYUT RATH |
| Issued | 3/14/2022 | APPLICANT |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 3/11/2022 | RICARDO BOHORQUEZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Foroutan-Naini,, Fardad; Lic. No.: C43935 | 8860 CORBIN AVE STE 212 NORTHRIDGE, CA 91324 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 4/3/2023 | Partial Inspection | GRANT WOODS |
| Deputy Drilled-In Anchors | 5/4/2023 | Conditional Approval | GRANT WOODS |
| Footing/Foundation/Slab | 5/9/2023 | Partial Approval | GRANT WOODS |
| Wood Frame | 5/16/2023 | Not Ready for Inspection | MICHAEL PETRUSKO |
| Deputy Wood Construction | 5/19/2023 | Conditional Approval | MICHAEL PETRUSKO |
| Floor/Roof Diaphrgm/Shear Wall | 5/19/2023 | Not Ready for Inspection | MICHAEL PETRUSKO |
| Wood Frame | 5/19/2023 | Not Ready for Inspection | MICHAEL PETRUSKO |
| Floor/Roof Diaphrgm/Shear Wall | 5/23/2023 | Approved | MICHAEL PETRUSKO |
| Wood Frame | 5/23/2023 | Approved | MICHAEL PETRUSKO |
| Drywall Nailing | 6/21/2023 | Approved | MICHAEL PETRUSKO |
| Interior/Exterior Lathing | 6/21/2023 | Approved | MICHAEL PETRUSKO |
| Final | 7/13/2023 | No Access for Inspection | MICHAEL PETRUSKO |
| SGSOV-Seismic Gas S/O Valve | 7/13/2023 | SGSOV Not Ready | MICHAEL PETRUSKO |
| Smoke Detectors | 7/13/2023 | Not Ready for Inspection | MICHAEL PETRUSKO |
| Final | 9/22/2023 | Not Ready for Inspection | MICHAEL PETRUSKO |
| SGSOV-Seismic Gas S/O Valve | 9/22/2023 | SGSOV Not Ready | MICHAEL PETRUSKO |