4617 N WILLIS AVE 91403
Certificate Information: 4617 N WILLIS AVE 91403
- Application / Permit
- 20016-10000-01393
- Plan Check / Job No.
- B20LA00865
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- E-plan Soft-Story seismic retrofit per LABC Chapter 93: Seismic Reinforcement at building garage using (3) special cantilevered columns with grade beams
- Permit Issued
- Issued on 2/8/2021
- Issuing Office
- Current Status
- CofC Issued on 10/7/2021
Permit Application Status History
| Submitted | 1/17/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 2/5/2020 | DANIEL YIP |
| Corrections Issued | 2/7/2020 | DANIEL YIP |
| Quality Review Completed | 2/20/2020 | HANS SANTIAGO |
| Applicant returned to address corrections | 3/6/2020 | DANIEL YIP |
| Plan Check Approved | 4/23/2020 | DANIEL YIP |
| Issued | 2/8/2021 | APPLICANT |
| OK for CofC | 7/12/2021 | KENNETH ROBERTS |
| CofC Issued | 10/7/2021 | KENNETH ROBERTS |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 2/8/2021 | ISMAEL HERNANDEZ |
Contact Information
| Contractor | Repipe 1 Restoration Inc; Lic. No.: 1003868-B | , |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 743 S SIERRA VISTA AVE C ALHAMBRA, CA 91801 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/9/2021 | Approved | HAMID PISHEHVAR |
| Deputy Steel/Welding | 3/16/2021 | Conditional Approval | JEFFREY DURAN |
| Footing/Foundation/Slab | 3/19/2021 | Approved | HAMID PISHEHVAR |
| Structural Steel Frame | 3/19/2021 | Approved | HAMID PISHEHVAR |
| Wood Frame | 3/19/2021 | Approved | HAMID PISHEHVAR |
| Deputy Reinf. Concrete | 3/23/2021 | Conditional Approval | BRUCE CAMPBELL |
| Interior/Exterior Lathing | 4/1/2021 | Approved | DANIEL VARNUM |
| Final | 5/24/2021 | No Access for Inspection | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 5/24/2021 | SGSOV Not Ready | DANIEL VARNUM |
| Smoke Detectors | 5/24/2021 | No Access for Inspection | DANIEL VARNUM |
| Final | 5/26/2021 | Partial Approval | DANIEL VARNUM |
| SGSOV-Seismic Gas S/O Valve | 5/26/2021 | SGSOV Approved | DANIEL VARNUM |
| Smoke Detectors | 5/26/2021 | Approved | DANIEL VARNUM |
| Final | 7/12/2021 | OK for CofC | KENNETH ROBERTS |