1530 S SALTAIR AVE 90025

Certificate Information: 1530 S SALTAIR AVE 90025

Application / Permit
20016-10000-00671
Plan Check / Job No.
B20LA00397
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Soft-Story seismic retrofit per LABC Chapter 93: INSTALL (4) STEEL CANTILEVER COLUMNS AND PLYWOOD SHEAR WALL.
Permit Issued
Issued on 10/26/2020
Issuing Office
Current Status
CofC Issued on 2/25/2022

Permit Application Status History

Submitted 1/30/2020 APPLICANT
Assigned to Plan Check Engineer 2/19/2020 DANIEL SANJUAN
Corrections Issued 3/5/2020 DANIEL SANJUAN
Quality Review Completed 3/11/2020 HANS SANTIAGO
Plan Check Approved 8/28/2020 DANIEL SANJUAN
Issued 10/26/2020 APPLICANT
OK for CofC 3/12/2021 GRANT WOODS
OK to Issue CofC 3/12/2021 TED RIES
CofC Issued 2/25/2022 DAVID TSAU

Permit Application Clearance Information

Address approval Cleared 8/14/2020 KATHLEEN LEE
Eng Process Fee Ord 176,300 Cleared 8/21/2020 KATHLEEN LEE
Tenant Habitability Plan Cleared 10/22/2020 PHILLIP MUNGUIA

Contact Information

Contractor Sturdy Builds Inc; Lic. No.: 1006879-B 21300 VICTORY BLVD SUITE 635      WOODLAND HILLS, CA 91367
Engineer Puliyadi,, Senthilnath Surendran; Lic. No.: NA71630       ,

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 11/13/2020 Approved PAUL DAVIDSON
Deputy Steel/Welding 12/23/2020 Conditional Approval GRANT WOODS
Deputy Drilled-In Anchors 1/7/2021 Conditional Approval JOHN DODGE
Excavation/Setback/Form/Re-Bar 1/8/2021 Approved JOHN DODGE
Wood Frame 1/8/2021 Not Ready for Inspection JOHN DODGE
Deputy Wood Construction 1/22/2021 Conditional Approval GRANT WOODS
Wood Frame 1/26/2021 Not Ready for Inspection GRANT WOODS
Deputy Wood Construction 1/28/2021 Conditional Approval GRANT WOODS
Interior/Exterior Lathing 2/10/2021 Approved GRANT WOODS
Final 3/2/2021 Not Ready for Inspection JOHN DODGE
SGSOV-Seismic Gas S/O Valve 3/2/2021 SGSOV Approved JOHN DODGE
Smoke Detectors 3/2/2021 Not Ready for Inspection JOHN DODGE
Final 3/12/2021 OK for CofC GRANT WOODS
Smoke Detectors 3/12/2021 Approved GRANT WOODS