3854 S INGLEWOOD BLVD 90066

Certificate Information: 3854 S INGLEWOOD BLVD 90066

Application / Permit
20016-10000-00356
Plan Check / Job No.
B20LA00213
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Eplan 1651 :: Soft-Story seismic retrofit per LABC Chapter 93: USING (3) SPECIAL CANTILEVERED COLUMNS WITH GRADE BEAMS.
Permit Issued
Issued on 5/19/2020
Issuing Office
Current Status
Issued on 5/19/2020

Permit Application Status History

Submitted 1/8/2020 APPLICANT
Assigned to Plan Check Engineer 1/29/2020 DANIEL YIP
Corrections Issued 2/5/2020 DANIEL YIP
Quality Review Completed 2/13/2020 HANS SANTIAGO
Applicant returned to address corrections 3/18/2020 DANIEL YIP
Applicant returned to address corrections 4/6/2020 DANIEL YIP
Plan Check Approved 5/1/2020 DANIEL YIP
Issued 5/19/2020 APPLICANT

Permit Application Clearance Information

Construction near power lines Cleared 3/2/2020 TORI CHEN
Tenant Habitability Plan Cleared 5/15/2020 PHILLIP MUNGUIA

Contact Information

Contractor Retrofitting360 Inc; Lic. No.: 1039226-B 19562 VENTURA BLVD# 230      TARZANA, CA 91356
Engineer Ni,, Zhang Yuan; Lic. No.: C68149 743 S SIERRA VISTA AVE C      ALHAMBRA, CA 91801

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 7/2/2020 Approved SORIN CIRSTOIU
Footing/Foundation/Slab 7/15/2020 Approved GRANT WOODS
Reinforced Concrete Frame 7/15/2020 Not Ready for Inspection GRANT WOODS
Structural Steel Frame 7/15/2020 Not Ready for Inspection GRANT WOODS
Wood Frame 7/15/2020 Not Ready for Inspection GRANT WOODS
Deputy Steel/Welding 7/16/2020 Conditional Approval GRANT WOODS
Reinforced Concrete Frame 7/20/2020 Not Ready for Inspection GRANT WOODS
Structural Steel Frame 7/20/2020 Approved GRANT WOODS
Wood Frame 7/20/2020 Approved GRANT WOODS
Reinforced Concrete Frame 7/30/2020 Not Ready for Inspection GRANT WOODS
Structural Steel Frame 7/30/2020 Approved GRANT WOODS
Wood Frame 7/30/2020 Approved GRANT WOODS
Interior/Exterior Lathing 8/6/2020 Approved GRANT WOODS
Final 8/11/2020 Conditional Approval GRANT WOODS
SGSOV-Seismic Gas S/O Valve 8/11/2020 SGSOV Approved GRANT WOODS
Smoke Detectors 8/11/2020 Approved GRANT WOODS
Final 8/25/2020 Not Ready for Inspection GRANT WOODS