709 S BURLINGAME AVE 90049
Certificate Information: 709 S BURLINGAME AVE 90049
- Application / Permit
- 20014-30000-02360
- Plan Check / Job No.
- B20WL02356
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ADDITION AND MAJOR REMODEL TO EXISTING 1-STORY TYPE VB SINGLE FAMILY DWELLING. 1ST AND 2ND STORY ADDITION, NEW ATTACHED 2-CAR GARAGE, EQUIPPED THROUGHOUT WITH NFPA 13D FIRE SPRINKLERS.
- Permit Issued
- Issued on 12/21/2020
- Issuing Office
- Current Status
- CofO Issued on 12/27/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/5/2020 | APPLICANT |
| Green Plans Picked Up | 6/24/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/2/2020 | SERGIO SILVA |
| Corrections Issued | 7/13/2020 | SERGIO SILVA |
| Quality Review Completed | 7/22/2020 | KAMRAN GHOTBI RAVANDI |
| Applicant returned to address corrections | 10/26/2020 | SERGIO SILVA |
| Applicant returned to address corrections | 11/12/2020 | SERGIO SILVA |
| Plan Check Approved | 12/7/2020 | SERGIO SILVA |
| Issued | 12/21/2020 | APPLICANT |
| Building Plans Picked Up | 12/23/2020 | APPLICANT |
| CofO in Progress | 12/3/2021 | OGANES TARAKHCHYAN |
| Permit Finaled | 12/27/2021 | KENNETH NAGLE |
| CofO Issued | 12/27/2021 | KENNETH NAGLE |
| Permit Finaled | 12/27/2021 | KENNETH NAGLE |
Permit Application Clearance Information
| Trees in Parkway | Cleared | 7/21/2020 | JOHN KIM |
| Permit | Cleared | 9/29/2020 | DINAH GARIN |
| Eng Process Fee Ord 176,300 | Cleared | 9/30/2020 | DINAH GARIN |
| Sewer availability | Cleared | 10/2/2020 | DINAH GARIN |
| Low Impact Development | Cleared | 10/7/2020 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 10/14/2020 | OSCAR GUTIERREZ |
| Specific Plan | Cleared | 10/14/2020 | FREDDY GARCIA |
Contact Information
| Architect | Niemerski,, Kenneth Chester; Lic. No.: C23971 | 52 DAWNWOOD LADERA RANCH, CA 92694 |
| Contractor | Tjc Home Builders Llc; Lic. No.: 1025507-B | 26880 ALISO VIEJO PKWY STE 100 ALISO VIEJO, CA 92656 |
| Engineer | De, Leon, Cynthia Aguilar; Lic. No.: C31604 | 8061 SAN MATEO CIR BUENA PARK, CA 90620 |
| Engineer | Nguyen,, Huan Ngoc; Lic. No.: C64238 | 13831 TYPEE WAY IRVINE, CA 92620 |
| Engineer | Toedter,, Randy W; Lic. No.: S2991 | 7474 EISENHOWER ST VENTURA, CA 93003 |
| Landscape Architect | Cortez,, Pablo Adrian; Lic. No.: LA6373 | 323 N RESH ST ANAHEIM, CA 92805 |
Inspector Information
| ANTHONY EGSON, (310) 914-3893 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 1/20/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Footing/Foundation/Slab | 1/27/2021 | Not Ready for Inspection | KENNETH NAGLE |
| Pre-Inspection | 1/27/2021 | Conditional Approval | KENNETH NAGLE |
| PLUMBING-Rough | 2/5/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Deputy Reinf. Concrete | 2/9/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Footing/Foundation/Slab | 2/10/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Footing/Foundation/Slab | 2/16/2021 | Approved | OGANES TARAKHCHYAN |
| Floor/Roof Diaphrgm/Shear Wall | 3/2/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Floor/Roof Diaphrgm/Shear Wall | 3/30/2021 | Partial Approval | KENNETH NAGLE |
| Deputy Wood Construction | 3/31/2021 | Partial Approval | OGANES TARAKHCHYAN |
| PLUMBING-Rough | 4/5/2021 | Approved | OGANES TARAKHCHYAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/8/2021 | Partial Approval | OGANES TARAKHCHYAN |
| ELECTRICAL-Rough | 4/15/2021 | Approved | OGANES TARAKHCHYAN |
| HVAC-Rough | 4/19/2021 | Corrections Issued | KEVIN SARGSYAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/21/2021 | Approved | KEVIN SARGSYAN |
| HVAC-Rough | 4/22/2021 | No Access for Inspection | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 4/26/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Shower Pan | 4/26/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Interior/Exterior Lathing | 4/29/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Shower Pan | 4/29/2021 | Approved | OGANES TARAKHCHYAN |
| HVAC-Rough | 5/7/2021 | Approved | OGANES TARAKHCHYAN |
| BUILDING-Rough-Frame | 5/10/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Green Building Rough | 5/10/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| BUILDING-Rough-Frame | 5/13/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Green Building Rough | 5/13/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| BUILDING-Rough-Frame | 5/18/2021 | Approved | OGANES TARAKHCHYAN |
| Green Building Rough | 5/18/2021 | Approved | OGANES TARAKHCHYAN |
| Insulation | 5/20/2021 | Conditional Approval | AMY COLIN |
| Interior/Exterior Lathing | 5/27/2021 | Partial Approval | OGANES TARAKHCHYAN |
| Drywall Nailing | 6/2/2021 | Approved | OGANES TARAKHCHYAN |
| Interior/Exterior Lathing | 6/17/2021 | Partial Approval | ADAM ESCOTO |
| ELECTRICAL-Final | 10/14/2021 | Approved | OGANES TARAKHCHYAN |
| PLUMBING-Final | 10/25/2021 | Approved | OGANES TARAKHCHYAN |
| HVAC-Final | 10/26/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Service/Power Release | 10/27/2021 | Approved | OGANES TARAKHCHYAN |
| Gas Test | 10/28/2021 | Approved | OGANES TARAKHCHYAN |
| HVAC-Final | 10/29/2021 | Partial Approval | OGANES TARAKHCHYAN |
| SGSOV-Seismic Gas S/O Valve | 11/10/2021 | SGSOV Not Ready | OGANES TARAKHCHYAN |
| Smoke Detectors | 11/10/2021 | Approved | OGANES TARAKHCHYAN |
| Final | 11/16/2021 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| Green Building Final | 11/16/2021 | Approved | OGANES TARAKHCHYAN |
| SGSOV-Seismic Gas S/O Valve | 11/16/2021 | SGSOV Approved | OGANES TARAKHCHYAN |
| HVAC-Final | 11/18/2021 | Approved | OGANES TARAKHCHYAN |
| Final | 11/22/2021 | Conditional Approval | OGANES TARAKHCHYAN |
| Final | 12/2/2021 | OK to Issue CofO | OGANES TARAKHCHYAN |
| Special/Order Compliance | 12/15/2021 | Corrections Issued | OGANES TARAKHCHYAN |
| Special/Order Compliance | 12/20/2021 | Conditional Approval | OGANES TARAKHCHYAN |