3333 W ATWATER AVE 90039
Certificate Information: 3333 W ATWATER AVE 90039
- Application / Permit
- 20014-30000-00694
- Plan Check / Job No.
- B20WL00771
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 125 SF ADDITION TO (E) SINGLE FAMILY DWELLING. ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 3/19/2020
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 2/13/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 2/14/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 2/21/2020 | PARISA ZAHABI |
| Corrections Issued | 2/21/2020 | PARISA ZAHABI |
| Building Plans Picked Up | 3/2/2020 | APPLICANT |
| Applicant returned to address corrections | 3/6/2020 | JAHANSHAH POURHASSAN |
| Plan Check Approved | 3/10/2020 | ALFREDO JARA |
| Issued | 3/19/2020 | LADBS |
| CofO in Progress | 2/8/2021 | HAMIK HARTOUNIAN |
| Permit Finaled | 2/13/2021 | DEROLD HAUFF |
| CofO Issued | 2/13/2021 | DEROLD HAUFF |
| Permit Finaled | 2/13/2021 | DEROLD HAUFF |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 3/6/2020 | ANTHONY MAINEZ |
| Roof/Waste drainage to street | Cleared | 3/6/2020 | ANTHONY MAINEZ |
| ZI | Cleared | 3/6/2020 | DENZEL HENDERSON |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Lotfi,, Fariborz Frank; Lic. No.: C49359 | 1547 PALISADES DR PACIFIC PALISADES, CA 90272 |
Inspector Information
| NICHOLAS LOPEZ, (213) 202-3224 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 4/2/2020 | Partial Approval | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 4/13/2020 | Conditional Approval | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 4/15/2020 | Partial Approval | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 4/15/2020 | Approved | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/20/2020 | Partial Approval | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/22/2020 | Partial Approval | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 4/28/2020 | Approved | OSVALDO PARAMO |
| Insulation | 4/28/2020 | Partial Approval | OSVALDO PARAMO |
| BUILDING-Rough-Frame | 4/30/2020 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Green Building Rough | 4/30/2020 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 5/5/2020 | Approved | HAMIK HARTOUNIAN |
| Insulation | 5/5/2020 | Approved | HAMIK HARTOUNIAN |
| Wood Frame | 5/5/2020 | Approved | HAMIK HARTOUNIAN |
| Drywall Nailing | 5/7/2020 | Approved | HAMIK HARTOUNIAN |
| Green Building Rough | 5/7/2020 | Approved | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 10/7/2020 | Approved | HAMIK HARTOUNIAN |
| ELECTRICAL-Final | 10/7/2020 | Approved | HAMIK HARTOUNIAN |
| Final | 10/7/2020 | Corrections Issued | HAMIK HARTOUNIAN |
| Green Building Final | 10/7/2020 | Approved | HAMIK HARTOUNIAN |
| HVAC-Final | 10/7/2020 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Final | 10/7/2020 | Approved | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 10/7/2020 | SGSOV Approved | HAMIK HARTOUNIAN |
| Smoke Detectors | 10/7/2020 | Approved | HAMIK HARTOUNIAN |
| Final | 12/30/2020 | OK to Issue CofO | HAMIK HARTOUNIAN |