3161 S CORINTH AVE 90066
Certificate Information: 3161 S CORINTH AVE 90066
- Application / Permit
- 20014-20000-05701
- Plan Check / Job No.
- B20VN16448
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- 1ST AND 2ND FLOOR ADDITION TO & CONVERT (E) GARAGE TO ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) AND (d). ALL WORK PER ENGINEERING. NFPA 13D FIRE SPRINKLERS REQUIRED THROUGHOUT.
- Permit Issued
- Issued on 9/21/2021
- Issuing Office
- Current Status
- Issued on 9/21/2021
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/22/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 1/14/2021 | COLIN LOREDO |
| Corrections Issued | 1/19/2021 | COLIN LOREDO |
| Quality Review Completed | 2/5/2021 | OMID HEDAYAT |
| Plan Check Approved | 9/14/2021 | COLIN LOREDO |
| Issued | 9/21/2021 | APPLICANT |
| Building Plans Picked Up | 9/23/2021 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 2/23/2021 | DENNIS BRAGIN |
| Sewer availability | Cleared | 2/23/2021 | DENNIS BRAGIN |
| Eng Process Fee Ord 176,300 | Cleared | 2/24/2021 | DENNIS BRAGIN |
| Specific Plan | Cleared | 3/1/2021 | VALERIA CEJA |
| Hydrant and Access approval | Cleared | 3/24/2021 | MATTHEW CRAIG |
| Construction near power lines | Cleared | 4/24/2021 | RIDWAN HARDY |
| Low Impact Development | Cleared | 8/27/2021 | SARAH YOUSSEF |
| Roof/Waste drainage to street | Cleared | 8/31/2021 | DENNIS BRAGIN |
Contact Information
| Architect | Sobhani,, Jamsheed Madadkar; Lic. No.: C29736 | 9045 BERTRAND AVENUE NORTHRIDGE, CA 913252811 |
| Contractor | Ender Enterprises; Lic. No.: 962814-B | 9903 SANTA MONICA BLVD #747 BEVERLY HILLS, CA 90212 |
| Engineer | Sadjadi,, Abdulreza; Lic. No.: C51812 | 1223 WILSHIRE BLVD #169 SANTA MONICA, CA 90403 |
Inspector Information
| KIRK SANDERS, (310) 914-3896 | Office Hours: 7:00-8:00 AM MON-FRI |
| ARAM AVEDISIAN, (310) 914-3896 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 2/18/2022 | Partial Approval | JOHNNY MIRANDA |
| Sewer | 2/18/2022 | Approved | JOHNNY MIRANDA |
| Underground Mechanical | 2/18/2022 | Approved | JOHNNY MIRANDA |
| ELECTRICAL-Rough | 2/25/2022 | Partial Approval | EVAN COOPER |
| PLUMBING-Rough | 2/25/2022 | Partial Approval | EVAN COOPER |
| Deputy Drilled-In Anchors | 3/4/2022 | Conditional Approval | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 3/4/2022 | Partial Approval | JOHNNY MIRANDA |
| Deputy Steel/Welding | 3/8/2022 | No Access for Inspection | KENNETH NAGLE |
| Deputy Wood Construction | 3/18/2022 | Approved | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 3/18/2022 | Partial Approval | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 4/27/2022 | Corrections Issued | JOHNNY MIRANDA |
| HVAC-Rough | 4/27/2022 | Approved | JOHNNY MIRANDA |
| Interior/Exterior Lathing | 4/27/2022 | Not Ready for Inspection | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 4/29/2022 | Approved | JOHNNY MIRANDA |
| PLUMBING-Rough | 4/29/2022 | Approved | JOHNNY MIRANDA |
| Shower Pan | 4/29/2022 | Approved | JOHNNY MIRANDA |
| Deputy Wood Construction | 5/2/2022 | Conditional Approval | JOHNNY MIRANDA |
| BUILDING-Rough-Frame | 5/13/2022 | Approved | JOHNNY MIRANDA |
| ELECTRICAL-Rough | 5/13/2022 | Approved | JOHNNY MIRANDA |
| Green Building Rough | 5/13/2022 | Approved | JOHNNY MIRANDA |
| Interior/Exterior Lathing | 5/13/2022 | Partial Approval | JOHNNY MIRANDA |
| MERV13>=Rough | 5/13/2022 | Approved | JOHNNY MIRANDA |
| Insulation | 5/19/2022 | Partial Approval | RYAN SALAZAR |
| Insulation | 5/20/2022 | Partial Approval | RYAN SALAZAR |
| Drywall Nailing | 5/25/2022 | Approved | JOHNNY MIRANDA |
| Insulation | 5/25/2022 | Approved | JOHNNY MIRANDA |
| Interior/Exterior Lathing | 5/25/2022 | Approved | JOHNNY MIRANDA |
| ELECTRICAL-Final | 8/11/2022 | Corrections Issued | JOHNNY MIRANDA |
| Final | 8/11/2022 | Corrections Issued | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 8/11/2022 | Approved | JOHNNY MIRANDA |
| Green Building Final | 8/11/2022 | Approved | JOHNNY MIRANDA |
| HVAC-Final | 8/11/2022 | Corrections Issued | JOHNNY MIRANDA |
| MERV13>=Final | 8/11/2022 | Approved | JOHNNY MIRANDA |
| PLUMBING-Final | 8/11/2022 | Approved | JOHNNY MIRANDA |
| SGSOV-Seismic Gas S/O Valve | 8/11/2022 | SGSOV Approved | JOHNNY MIRANDA |
| Smoke Detectors | 8/11/2022 | Approved | JOHNNY MIRANDA |
| Final | 8/16/2022 | Corrections Issued | JOHNNY MIRANDA |