12245 W HATTERAS ST 91607

Certificate Information: 12245 W HATTERAS ST 91607

Application / Permit
20014-20000-04884
Plan Check / Job No.
B20VN14387
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW 16' X 12' AND 16' X 10' ADDITIONS TO AND CONVERT THE (E) 20' X 20' DETACHED GARAGE INTO A (N) ACCESSORY DWELLING UNIT PER LAMC.12.22.A.33(C) AND (E), REMOVE 9' X 12' ATTACHED WORKSHOP , ALL WORK PER ENGINEERING
Permit Issued
Issued on 6/14/2021
Issuing Office
Valley
Current Status
Issued on 6/14/2021
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 12/1/2020 APPLICANT
Assigned to Plan Check Engineer 12/11/2020 RARES BODEA
Corrections Issued 12/13/2020 RARES BODEA
Building Plans Picked Up 12/15/2020 APPLICANT
Plan Check Approved 6/7/2021 RARES BODEA
Issued 6/14/2021 APPLICANT

Permit Application Clearance Information

Address approval Cleared 2/23/2021 JOHN TRIANTAFYLLOS
Eng Process Fee Ord 176,300 Cleared 2/25/2021 JOHN TRIANTAFYLLOS
Sewer availability Cleared 2/25/2021 JOHN TRIANTAFYLLOS
Roof/Waste drainage to street Cleared 5/5/2021 JEANIE LAM
Construction near power lines Cleared 5/26/2021 RIDWAN HARDY
Construction within easement Cleared 5/26/2021 RIDWAN HARDY

Contact Information

Contractor Owner-Builder       ,
Engineer Dominguez,, Refugio; Lic. No.: C50820 254 COTTONWOOD ST      ONTARIO, CA 91761

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/13/2021 Partial Approval CHRISTOPHE COCHRAN
PLUMBING-Rough 7/13/2021 Partial Approval CHRISTOPHE COCHRAN
Underground Mechanical 7/13/2021 Approved CHRISTOPHE COCHRAN
Footing/Foundation/Slab 7/20/2021 Not Ready for Inspection CHRISTOPHE COCHRAN
Footing/Foundation/Slab 7/26/2021 Not Ready for Inspection CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 7/28/2021 Partial Approval CHRISTOPHE COCHRAN
Footing/Foundation/Slab 7/28/2021 Approved CHRISTOPHE COCHRAN
BUILDING-Rough-Frame 8/11/2021 Not Ready for Inspection CHRISTOPHE COCHRAN
ELECTRICAL-Rough 8/11/2021 Not Ready for Inspection CHRISTOPHE COCHRAN
Green Building Rough 8/11/2021 Approved CHRISTOPHE COCHRAN
HVAC-Rough 8/11/2021 Approved CHRISTOPHE COCHRAN
PLUMBING-Rough 8/11/2021 Approved CHRISTOPHE COCHRAN
BUILDING-Rough-Frame 8/17/2021 Partial Approval ARAM AVEDISIAN
ELECTRICAL-Rough 8/17/2021 Corrections Issued ARAM AVEDISIAN
Insulation 8/25/2021 Corrections Issued CHRISTOPHER DELLEFIELD
BUILDING-Rough-Frame 8/30/2021 Approved CHRISTOPHE COCHRAN
ELECTRICAL-Rough 8/30/2021 Approved CHRISTOPHE COCHRAN
Insulation 8/30/2021 Approved CHRISTOPHE COCHRAN
Interior/Exterior Lathing 9/1/2021 Partial Approval CHRISTOPHE COCHRAN
Drywall Nailing 9/3/2021 Approved CHRISTOPHE COCHRAN
Interior/Exterior Lathing 9/3/2021 Partial Approval CHRISTOPHE COCHRAN
Gas Test 11/1/2021 Approved CHRISTOPHE COCHRAN
Sewer 11/1/2021 Approved CHRISTOPHE COCHRAN
Shower Pan 11/1/2021 Approved CHRISTOPHE COCHRAN
Final 4/26/2022 Corrections Issued CHRISTOPHE COCHRAN
Green Building Final 4/26/2022 Not Ready for Inspection CHRISTOPHE COCHRAN
SGSOV-Seismic Gas S/O Valve 4/26/2022 SGSOV Approved CHRISTOPHE COCHRAN
Smoke Detectors 4/26/2022 Approved CHRISTOPHE COCHRAN
Final 6/8/2022 Not Ready for Inspection CHRISTOPHE COCHRAN
Green Building Final 6/8/2022 Not Ready for Inspection CHRISTOPHE COCHRAN
Final 3/3/2023 Corrections Issued KIRK SANDERS
Green Building Final 3/3/2023 Approved KIRK SANDERS