6224 N VAN NOORD AVE 91401
Certificate Information: 6224 N VAN NOORD AVE 91401
- Application / Permit
- 20014-20000-04280
- Plan Check / Job No.
- B20VN12838
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- MAJOR INTERIOR REMODEL TO (E) SFD TO REVISE ENTIRE FLOOR PLAN LAYOUT WITH 29' 8" X 33' 6" 2ND FLOOR ADDITION, 12' X 26' 6" TRELLIS ADDITION, 4' 3" X 11' 5" COVERD PORCH ADDITION AND REMOVE (E) FRONT COVERED PORCH. ALL WORK DONE PER ENGINEERING.
- Permit Issued
- Issued on 2/14/2022
- Issuing Office
- Current Status
- CofO Issued on 10/23/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/27/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 11/6/2020 | GURUNATH NESARAJAH |
| Corrections Issued | 11/7/2020 | GURUNATH NESARAJAH |
| Applicant returned to address corrections | 5/26/2021 | GURUNATH NESARAJAH |
| Building Plans Picked Up | 5/26/2021 | APPLICANT |
| Plan Check Approved | 2/7/2022 | GURUNATH NESARAJAH |
| Issued | 2/14/2022 | APPLICANT |
| CofO in Progress | 9/27/2023 | JUAN VALENZUELA |
| CofO Issued | 10/23/2023 | RUBEN SALAS |
| Permit Finaled | 10/23/2023 | RUBEN SALAS |
Permit Application Clearance Information
| Sewer availability | Cleared | 8/25/2021 | DAGOVERTO GUERRERO |
| Eng Process Fee Ord 176,300 | Cleared | 8/26/2021 | DAGOVERTO GUERRERO |
| Low Impact Development | Cleared | 12/2/2021 | CHRIS VONG |
| Roof/Waste drainage to street | Cleared | 12/7/2021 | JOHN LIN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Adzhemyan,, Arsen; Lic. No.: C89103 | 1010 RALEIGH ST APT 107 GLENDALE, CA 91205 |
Inspector Information
| WAYNE REGESTER, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 4/1/2022 | Approved | CHRISTOPHE COCHRAN |
| Deputy Drilled-In Anchors | 4/7/2022 | Partial Approval | MATT KELLERMAN |
| Deputy Drilled-In Anchors | 4/12/2022 | Conditional Approval | CHRISTOPHE COCHRAN |
| Pre-Inspection | 4/14/2022 | Approved | CHRISTOPHE COCHRAN |
| Excavation/Setback/Form/Re-Bar | 4/19/2022 | Approved | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 4/19/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 5/2/2022 | No Access for Inspection | CHRISTOPHE COCHRAN |
| Light Gage Steel Frame | 5/2/2022 | No Access for Inspection | CHRISTOPHE COCHRAN |
| SGSOV-Seismic Gas S/O Valve | 5/2/2022 | SGSOV Not Ready | CHRISTOPHE COCHRAN |
| Wood Frame | 5/2/2022 | No Access for Inspection | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 5/4/2022 | Approved | CHRISTOPHE COCHRAN |
| Wood Frame | 5/4/2022 | Corrections Issued | CHRISTOPHE COCHRAN |
| Deputy Reinf. Concrete | 5/5/2022 | Conditional Approval | MICHAEL TEMPLE |
| PLUMBING-Rough | 5/6/2022 | Corrections Issued | CHRISTOPHE COCHRAN |
| Wood Frame | 5/6/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 5/10/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Insulation | 5/12/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Floor/Roof Diaphrgm/Shear Wall | 5/17/2022 | Partial Approval | JACK KARGODORIAN |
| Floor/Roof Diaphrgm/Shear Wall | 6/27/2022 | Approved | RAFAEL CORTES |
| Pre-Inspection | 8/4/2022 | Approved | RAFAEL CORTES |
| BUILDING-Rough-Frame | 8/29/2022 | Not Ready for Inspection | RAFAEL CORTES |
| Green Building Rough | 8/29/2022 | Not Ready for Inspection | RAFAEL CORTES |
| HVAC-Rough | 8/29/2022 | Corrections Issued | RAFAEL CORTES |
| ELECTRICAL-Rough | 9/28/2022 | Not Ready for Inspection | RAFAEL CORTES |
| HVAC-Rough | 9/28/2022 | Not Ready for Inspection | RAFAEL CORTES |
| PLUMBING-Rough | 9/28/2022 | Not Ready for Inspection | RAFAEL CORTES |
| BUILDING-Rough-Frame | 10/3/2022 | Corrections Issued | RAFAEL CORTES |
| ELECTRICAL-Rough | 10/3/2022 | Approved | RAFAEL CORTES |
| Floor/Roof Diaphrgm/Shear Wall | 10/3/2022 | Approved | RAFAEL CORTES |
| HVAC-Rough | 10/3/2022 | Not Ready for Inspection | RAFAEL CORTES |
| PLUMBING-Rough | 10/11/2022 | Not Ready for Inspection | RAFAEL CORTES |
| Shower Pan | 10/11/2022 | Not Ready for Inspection | RAFAEL CORTES |
| PLUMBING-Rough | 10/17/2022 | Approved | WILLIAM WREN |
| Shower Pan | 10/17/2022 | Approved | WILLIAM WREN |
| BUILDING-Rough-Frame | 10/18/2022 | Conditional Approval | CALEB MEISTER |
| Green Building Rough | 10/18/2022 | Approved | CALEB MEISTER |
| HVAC-Rough | 10/18/2022 | Approved | CALEB MEISTER |
| Interior/Exterior Lathing | 10/18/2022 | Approved | CALEB MEISTER |
| Insulation | 10/24/2022 | Approved | CALEB MEISTER |
| Verify Sprinkler Sign Off | 10/25/2022 | Corrections Issued | CALEB MEISTER |
| Interior/Exterior Lathing | 11/1/2022 | Partial Approval | JENNIFER RABUCHIN |
| Special/Order Compliance | 11/1/2022 | Corrections Issued | JENNIFER RABUCHIN |
| Interior/Exterior Lathing | 11/29/2022 | Approved | KIRK SANDERS |
| Drywall Nailing | 12/29/2022 | Partial Approval | KIRK SANDERS |
| Drywall Nailing | 1/6/2023 | Approved | KIRK SANDERS |
| ELECTRICAL-Final | 3/22/2023 | Not Ready for Inspection | KIRK SANDERS |
| Pre-Inspection | 7/5/2023 | Not Ready for Inspection | KIRK SANDERS |
| BUILDING-Rough-Frame | 8/23/2023 | Approved | KIRK SANDERS |
| Final | 8/23/2023 | Corrections Issued | KIRK SANDERS |
| Green Building Final | 8/23/2023 | Approved | KIRK SANDERS |
| SGSOV-Seismic Gas S/O Valve | 8/23/2023 | SGSOV Approved | KIRK SANDERS |
| Smoke Detectors | 8/23/2023 | Approved | KIRK SANDERS |
| Final | 8/28/2023 | Corrections Issued | KIRK SANDERS |
| Final | 9/11/2023 | OK to Issue CofO | JUAN VALENZUELA |