16533 W OLDHAM ST 91436
Certificate Information: 16533 W OLDHAM ST 91436
- Application / Permit
- 20014-20000-04202
- Plan Check / Job No.
- B20VN12631
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSE (N) 2ND FLOOR, (N) BASEMENT, AND 1ST FLOOR ADDITION TO (E) SFD AND MAJOR REMODEL_BUILDING SHALL BE FULLY SPRINKLER THROUGH OUT WITH NFPA 13D.
- Permit Issued
- Issued on 3/14/2022
- Issuing Office
- Current Status
- Issued on 3/14/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 9/25/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 10/15/2020 | CHON CHIO KUO |
| Corrections Issued | 10/29/2020 | CHON CHIO KUO |
| Quality Review Completed | 11/6/2020 | STEVEN KIM |
| Building Plans Picked Up | 11/6/2020 | APPLICANT |
| Applicant returned to address corrections | 5/17/2021 | CHON CHIO KUO |
| Applicant returned to address corrections | 8/17/2021 | DAWN MC NULTY |
| Applicant returned to address corrections | 1/6/2022 | DAWN MC NULTY |
| Plan Check Approved | 3/7/2022 | DAWN MC NULTY |
| Issued | 3/14/2022 | APPLICANT |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 1/14/2021 | GUILLERMO PETRA |
| BHO/Hillside ordinance | Cleared | 1/14/2021 | GUILLERMO PETRA |
| BHO/Hillside ordinance | Cleared | 1/14/2021 | GUILLERMO PETRA |
| BHO/Hillside ordinance | Cleared | 1/14/2021 | GUILLERMO PETRA |
| BHO/Hillside ordinance | Cleared | 1/14/2021 | GUILLERMO PETRA |
| Permit | Cleared | 1/22/2021 | GUILLERMO PETRA |
| Sewer availability | Cleared | 1/22/2021 | GUILLERMO PETRA |
| Eng Process Fee Ord 176,300 | Cleared | 1/26/2021 | GUILLERMO PETRA |
| Hydrant and Access approval | Cleared | 4/2/2021 | JOHN CONNEALLY |
| Low Impact Development | Cleared | 4/27/2021 | JORGE MEJIA LEMUS |
| Roof/Waste drainage to street | Cleared | 8/10/2021 | DAGOVERTO GUERRERO |
| Excavation more than 5-ft deep | Cleared | 8/17/2021 | CALOSHA APPROVED |
| GPI Written Notices | Cleared | 8/17/2021 | CHON CHIO KUO |
| Grading Pre-Inspection | Cleared | 8/17/2021 | CHON CHIO KUO |
| Miscellaneous | Cleared | 8/17/2021 | CHON CHIO KUO |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Abrahamian,, Zaven; Lic. No.: C41672 | 237 S LAMER ST BURBANK, CA 91506 |
| Engineer | Martirosian,, Hayk Sam; Lic. No.: C52563 | 537 NOLAN AVE GLENDALE, CA 91202 |
| Engineer | Martirossyan,, Armen; Lic. No.: C64223 | 802 PORTOLA AVE GLENDALE, CA 91206 |
Inspector Information
| THOMAS FINNILA, (818) 774-4324 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 6/9/2022 | Partial Approval | ROBERT GOLD |
| Deputy Reinf. Concrete | 6/13/2022 | Approved | JEFFREY BULL |
| Deputy Reinf. Concrete | 6/13/2022 | Partial Approval | ROBERT GOLD |
| Masonry Wall/Backfill | 7/6/2022 | Partial Approval | DAVID SANDOVAL |
| Reinforced Masonry Frame | 7/6/2022 | Partial Approval | DAVID SANDOVAL |
| Deputy Shotcrete | 7/8/2022 | Approved | VINCENT HANLEY |
| PLUMBING-Rough | 8/12/2022 | Corrections Issued | VINCENT HANLEY |
| PLUMBING-Rough | 8/15/2022 | Partial Approval | VINCENT HANLEY |
| Footing/Foundation/Slab | 8/19/2022 | Partial Approval | VINCENT HANLEY |
| Footing/Foundation/Slab | 9/9/2022 | Partial Approval | VINCENT HANLEY |
| PLUMBING-Rough | 12/9/2022 | Partial Approval | VINCENT HANLEY |
| Deputy Drilled-In Anchors | 12/23/2022 | Approved | VINCENT HANLEY |
| Footing/Foundation/Slab | 12/27/2022 | Corrections Issued | SEAN HAUPT |
| Grounding or Bonding | 12/27/2022 | Partial Approval | SEAN HAUPT |
| Excavation/Setback/Form/Re-Bar | 12/28/2022 | Approved | VINCENT HANLEY |
| Footing/Foundation/Slab | 12/28/2022 | Approved | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 2/6/2023 | Partial Approval | VINCENT HANLEY |
| Deputy Wood Construction | 2/22/2023 | Approved | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 2/24/2023 | Partial Inspection | JESUS PINEDA |
| BUILDING-Rough-Frame | 3/6/2023 | Corrections Issued | VINCENT HANLEY |
| Floor/Roof Diaphrgm/Shear Wall | 3/6/2023 | Partial Approval | VINCENT HANLEY |
| Special/Order Compliance | 3/6/2023 | Partial Inspection | JUSTIN HAWLEY |
| Special/Order Compliance | 4/20/2023 | Approved | VINCENT HANLEY |
| BUILDING-Rough-Frame | 5/2/2023 | Corrections Issued | VINCENT HANLEY |
| Green Building Rough | 5/2/2023 | Not Ready for Inspection | VINCENT HANLEY |
| HVAC-Rough | 5/2/2023 | Approved | VINCENT HANLEY |
| PLUMBING-Rough | 5/2/2023 | Approved | VINCENT HANLEY |
| Verify Sprinkler Sign Off | 5/2/2023 | Not Ready for Inspection | VINCENT HANLEY |
| BUILDING-Rough-Frame | 5/10/2023 | Partial Approval | VINCENT HANLEY |
| ELECTRICAL-Rough | 5/10/2023 | Approved | VINCENT HANLEY |
| Green Building Rough | 5/10/2023 | Not Ready for Inspection | VINCENT HANLEY |
| Verify Sprinkler Sign Off | 5/10/2023 | Approved | VINCENT HANLEY |
| BUILDING-Rough-Frame | 5/26/2023 | Approved | VINCENT HANLEY |
| Green Building Rough | 5/26/2023 | Approved | VINCENT HANLEY |
| Interior/Exterior Lathing | 5/26/2023 | Partial Approval | VINCENT HANLEY |
| Insulation | 6/8/2023 | Approved | VINCENT HANLEY |
| Drywall Nailing | 6/14/2023 | Approved | VINCENT HANLEY |
| Shower Pan | 6/14/2023 | Approved | VINCENT HANLEY |
| Interior/Exterior Lathing | 7/5/2023 | Approved | VINCENT HANLEY |
| ELECTRICAL-Final | 5/9/2024 | Approved | VINCENT HANLEY |
| Final | 5/9/2024 | Corrections Issued | VINCENT HANLEY |
| Green Building Final | 5/9/2024 | Approved | VINCENT HANLEY |
| HVAC-Final | 5/9/2024 | Approved | VINCENT HANLEY |
| PLUMBING-Final | 5/9/2024 | Approved | VINCENT HANLEY |
| SGSOV-Seismic Gas S/O Valve | 5/9/2024 | SGSOV Approved | VINCENT HANLEY |
| Smoke Detectors | 5/9/2024 | Approved | VINCENT HANLEY |