11671 W SUNSHINE TER 91604

Certificate Information: 11671 W SUNSHINE TER 91604

Application / Permit
20014-20000-03739
Plan Check / Job No.
B20VN11392
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 9'1" X 12'6"ADDITION TO REAR OF (E) SFD TO ENLARGE THE PANTRY AND CREATE NEW LAUNDRY ROOM , INTERIOR REMODEL TO CONVERT THE MUDROOM TO A PANTRY , ALL WORK PER ENGINEERING - SEE COMMENTS
Permit Issued
Issued on 11/25/2020
Issuing Office
Current Status
Issued on 11/25/2020
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 9/21/2020 APPLICANT
Assigned to Plan Check Engineer 10/1/2020 RARES BODEA
Corrections Issued 10/1/2020 RARES BODEA
Building Plans Picked Up 10/5/2020 APPLICANT
Plan Check Approved 11/13/2020 RARES BODEA
Issued 11/25/2020 APPLICANT

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 10/21/2020 JOHN TRIANTAFYLLOS
Eng Process Fee Ord 176,300 Cleared 10/26/2020 JOHN TRIANTAFYLLOS
Grading Pre-Inspection Cleared 10/26/2020 PATRICK MISCHLICH

Contact Information

Contractor Axellon Construction; Lic. No.: 788047-B 9556 SYLVIA AVE      NORTHRIDGE, CA 91324
Engineer Reith,, David Lee; Lic. No.: C72122 1319 FEATHER AVE      THOUSAND OAKS, CA 91360

Inspector Information

CHRISTOPHE COCHRAN, (818) 374-1165 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 12/14/2020 Conditional Approval ARAM AVEDISIAN
Excavation/Setback/Form/Re-Bar 12/15/2020 Approved ARAM AVEDISIAN
Footing/Foundation/Slab 12/15/2020 Approved ARAM AVEDISIAN
BUILDING-Rough-Frame 12/22/2020 Partial Approval ARAM AVEDISIAN
ELECTRICAL-Rough 12/24/2020 Partial Approval ARAM AVEDISIAN
PLUMBING-Rough 12/24/2020 Partial Approval ARAM AVEDISIAN
Floor/Roof Diaphrgm/Shear Wall 1/5/2021 Partial Approval ARAM AVEDISIAN
Floor/Roof Diaphrgm/Shear Wall 1/27/2021 Approved ARAM AVEDISIAN
Interior/Exterior Lathing 2/3/2021 Partial Approval ARAM AVEDISIAN
Insulation 2/17/2021 Approved ARAM AVEDISIAN
Drywall Nailing 2/24/2021 Approved ARAM AVEDISIAN
Green Building Rough 2/24/2021 Approved ARAM AVEDISIAN
BUILDING-Rough-Frame 8/24/2021 Approved CHRISTOPHER DELLEFIELD
Final 8/24/2021 Corrections Issued CHRISTOPHER DELLEFIELD
Green Building Final 8/24/2021 Approved CHRISTOPHER DELLEFIELD
SGSOV-Seismic Gas S/O Valve 8/24/2021 SGSOV Not Ready CHRISTOPHER DELLEFIELD
Smoke Detectors 8/24/2021 Approved CHRISTOPHER DELLEFIELD
Final 9/28/2021 Corrections Issued ARAM AVEDISIAN
SGSOV-Seismic Gas S/O Valve 9/28/2021 SGSOV Approved ARAM AVEDISIAN
Final 10/5/2021 Corrections Issued ARAM AVEDISIAN