6730 N ALCOVE AVE 91606
Certificate Information: 6730 N ALCOVE AVE 91606
- Application / Permit
- 20014-20000-02957
- Plan Check / Job No.
- B20VN09285
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSED 11'X14'10" CLOSET & BATHRM ADDITION AT FRONT. ALL WORK PER WFPP.
- Permit Issued
- Issued on 9/10/2020
- Issuing Office
- Current Status
- CofO Issued on 10/15/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/15/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/17/2020 | JESSE ARELLANO |
| Corrections Issued | 7/18/2020 | JESSE ARELLANO |
| Applicant returned to address corrections | 8/13/2020 | HAYATO TSUCHIYA |
| Plan Check Approved | 9/10/2020 | LUIS RINCON |
| Issued | 9/10/2020 | APPLICANT |
| CofO in Progress | 10/4/2021 | CHRISTOPHE COCHRAN |
| Permit Finaled | 10/15/2021 | MICHAEL SMITH |
| CofO Issued | 10/15/2021 | MICHAEL SMITH |
| Permit Finaled | 10/15/2021 | MICHAEL SMITH |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 8/5/2020 | JOHN TRIANTAFYLLOS |
| Roof/Waste drainage to street | Cleared | 8/5/2020 | JOHN TRIANTAFYLLOS |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| WAYNE REGESTER, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 7/6/2021 | Conditional Approval | MORRIS JACKSON |
| PLUMBING-Rough | 7/9/2021 | Partial Approval | RICHARD DOCKUS |
| Deputy Drilled-In Anchors | 7/14/2021 | Approved | RICHARD DOCKUS |
| Footing/Foundation/Slab | 7/14/2021 | Approved | RICHARD DOCKUS |
| BUILDING-Rough-Frame | 7/27/2021 | Partial Approval | CHRISTOPHE COCHRAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/30/2021 | Not Ready for Inspection | KRISTEN CAUSEY |
| Insulation | 7/30/2021 | Partial Approval | KRISTEN CAUSEY |
| BUILDING-Rough-Frame | 8/13/2021 | Not Ready for Inspection | CHRISTOPHER DELLEFIELD |
| ELECTRICAL-Rough | 8/13/2021 | Approved | CHRISTOPHER DELLEFIELD |
| Floor/Roof Diaphrgm/Shear Wall | 8/13/2021 | Partial Approval | CHRISTOPHER DELLEFIELD |
| Green Building Rough | 8/13/2021 | Not Ready for Inspection | CHRISTOPHER DELLEFIELD |
| HVAC-Rough | 8/13/2021 | Not Ready for Inspection | CHRISTOPHER DELLEFIELD |
| PLUMBING-Rough | 8/13/2021 | Corrections Issued | CHRISTOPHER DELLEFIELD |
| HVAC-Rough | 8/23/2021 | Approved | MICHAEL PELHAM |
| PLUMBING-Rough | 8/23/2021 | Approved | MICHAEL PELHAM |
| Deputy Drilled-In Anchors | 8/24/2021 | Conditional Approval | MICHAEL PELHAM |
| BUILDING-Rough-Frame | 8/26/2021 | Approved | CHRISTOPHE COCHRAN |
| Green Building Rough | 8/26/2021 | Approved | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 9/2/2021 | Partial Approval | ARAM AVEDISIAN |
| Insulation | 9/3/2021 | Approved | ALIZAH MAYAGOITIA |
| Shower Pan | 9/3/2021 | Approved | ALIZAH MAYAGOITIA |
| Drywall Nailing | 9/9/2021 | Approved | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 9/9/2021 | Partial Inspection | CHRISTOPHE COCHRAN |
| Final | 9/30/2021 | Corrections Issued | CHRISTOPHE COCHRAN |
| Green Building Final | 9/30/2021 | Approved | CHRISTOPHE COCHRAN |
| SGSOV-Seismic Gas S/O Valve | 9/30/2021 | SGSOV Approved | CHRISTOPHE COCHRAN |
| Smoke Detectors | 9/30/2021 | Approved | CHRISTOPHE COCHRAN |
| Final | 10/4/2021 | OK to Issue CofO | CHRISTOPHE COCHRAN |