6742 N TOBIAS AVE 91405
Certificate Information: 6742 N TOBIAS AVE 91405
- Application / Permit
- 20014-20000-02534
- Plan Check / Job No.
- B20VN08166
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ADD 17'-5" X 28'-2" FOR TWO NEW BEDROOMS/BATHROOM/CLOSETS, REMODEL (E) 1-STORY SFD THROUGHOUT. ALL WORK PER WFPP.
- Permit Issued
- Issued on 11/17/2020
- Issuing Office
- Current Status
- CofO Corrected on 4/11/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/18/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 6/25/2020 | JENNIFER LEE |
| Corrections Issued | 6/25/2020 | JENNIFER LEE |
| Plan Check Approved | 11/12/2020 | JENNIFER LEE |
| Issued | 11/17/2020 | APPLICANT |
| CofO in Progress | 8/31/2022 | RICHARD DOCKUS |
| CofO Issued-Status Void | 9/6/2022 | MICHAEL SMITH |
| Permit Finaled-Status Void | 9/6/2022 | MICHAEL SMITH |
| Re-Activate Permit | 1/14/2023 | MICHAEL SMITH |
| CofO Corrected-Status Void | 1/14/2023 | MICHAEL SMITH |
| Permit Finaled-Status Void | 1/14/2023 | MICHAEL SMITH |
| Re-Activate Permit | 4/11/2023 | MICHAEL SMITH |
| CofO Corrected | 4/11/2023 | MICHAEL SMITH |
| Permit Finaled | 4/11/2023 | MICHAEL SMITH |
Permit Application Clearance Information
| "Q" conditions | Cleared | 7/1/2020 | MIGUEL GAMBOA |
| CPC | Cleared | 7/1/2020 | MIGUEL GAMBOA |
| Eng Process Fee Ord 176,300 | Cleared | 7/1/2020 | GABRIEL ROBLES |
| Sewer availability | Cleared | 7/1/2020 | GABRIEL ROBLES |
| Low Impact Development | Cleared | 10/23/2020 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 10/30/2020 | ADRIAN CASTRO |
Contact Information
| Architect | Akopian,, Harout; Lic. No.: C37146 | 2124 ARMOUR PL GLENDALE, CA 91208 |
| Contractor | Owner-Builder | , |
Inspector Information
| JOSE AVILA, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
| VINCENT HANLEY, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/23/2020 | Approved | DAVID MATSON |
| BUILDING-Rough-Frame | 1/4/2021 | Partial Approval | JENNIFER RABUCHIN |
| PLUMBING-Rough | 1/4/2021 | Partial Approval | JENNIFER RABUCHIN |
| Special/Order Compliance | 1/4/2021 | Corrections Issued | JENNIFER RABUCHIN |
| Insulation | 1/5/2021 | Partial Approval | JENNIFER RABUCHIN |
| Floor/Roof Diaphrgm/Shear Wall | 1/6/2021 | Partial Approval | JENNIFER RABUCHIN |
| BUILDING-Rough-Frame | 1/22/2021 | Partial Approval | JENNIFER RABUCHIN |
| Floor/Roof Diaphrgm/Shear Wall | 1/22/2021 | Partial Approval | JENNIFER RABUCHIN |
| Green Building Rough | 1/22/2021 | Not Ready for Inspection | JENNIFER RABUCHIN |
| BUILDING-Rough-Frame | 2/2/2021 | Corrections Issued | MICHEL ABAJAN |
| Green Building Rough | 2/2/2021 | Not Ready for Inspection | MICHEL ABAJAN |
| PLUMBING-Rough | 2/5/2021 | Not Ready for Inspection | RONALD COWAN |
| BUILDING-Rough-Frame | 2/8/2021 | Approved | JENNIFER RABUCHIN |
| Green Building Rough | 2/8/2021 | Not Ready for Inspection | JENNIFER RABUCHIN |
| PLUMBING-Rough | 2/8/2021 | Approved | JENNIFER RABUCHIN |
| BUILDING-Rough-Frame | 3/3/2021 | Corrections Issued | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 3/3/2021 | Not Ready for Inspection | JOHN HAYES |
| BUILDING-Rough-Frame | 4/12/2021 | Corrections Issued | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 4/12/2021 | Not Ready for Inspection | JOHN HAYES |
| ELECTRICAL-Rough | 5/3/2021 | Corrections Issued | MISAEL ESPARZA |
| HVAC-Rough | 5/3/2021 | Corrections Issued | MISAEL ESPARZA |
| BUILDING-Rough-Frame | 10/4/2021 | Approved | RICHARD DOCKUS |
| ELECTRICAL-Rough | 10/4/2021 | Approved | RICHARD DOCKUS |
| Green Building Rough | 10/4/2021 | Approved | RICHARD DOCKUS |
| HVAC-Rough | 10/4/2021 | Approved | RICHARD DOCKUS |
| PLUMBING-Rough | 10/4/2021 | Approved | RICHARD DOCKUS |
| ELECTRICAL-Rough | 10/18/2021 | Corrections Issued | ALAN MORELOS |
| Pre-Inspection | 10/19/2021 | Partial Approval | RICHARD DOCKUS |
| Pre-Inspection | 10/19/2021 | Partial Inspection | MICHAEL TEMPLE |
| BUILDING-Rough-Frame | 10/20/2021 | Partial Approval | RICHARD DOCKUS |
| Final | 10/20/2021 | Not Ready for Inspection | RICHARD DOCKUS |
| Green Building Rough | 10/20/2021 | Approved | RICHARD DOCKUS |
| SGSOV-Seismic Gas S/O Valve | 10/20/2021 | SGSOV Not Ready | RICHARD DOCKUS |
| Smoke Detectors | 10/20/2021 | Not Ready for Inspection | RICHARD DOCKUS |
| BUILDING-Rough-Frame | 10/25/2021 | Approved | RICHARD DOCKUS |
| Insulation | 10/25/2021 | Approved | RICHARD DOCKUS |
| Drywall Nailing | 10/28/2021 | Approved | RICHARD DOCKUS |
| Interior/Exterior Lathing | 11/23/2021 | Approved | RICHARD DOCKUS |
| Green Building Final | 1/6/2022 | Approved | RICHARD DOCKUS |
| SGSOV-Seismic Gas S/O Valve | 1/6/2022 | SGSOV Not Ready | RICHARD DOCKUS |
| Smoke Detectors | 1/6/2022 | Corrections Issued | RICHARD DOCKUS |
| Final | 1/7/2022 | Corrections Issued | JOHN KIDWELL |
| Final | 1/12/2022 | Corrections Issued | RICHARD DOCKUS |
| PLUMBING-Final | 1/12/2022 | Approved | RICHARD DOCKUS |
| SGSOV-Seismic Gas S/O Valve | 1/12/2022 | SGSOV Approved | RICHARD DOCKUS |
| Smoke Detectors | 1/12/2022 | Approved | RICHARD DOCKUS |
| Final | 2/4/2022 | Not Ready for Inspection | RICHARD DOCKUS |
| Final | 8/12/2022 | Corrections Issued | RICHARD DOCKUS |
| Gas Test | 8/18/2022 | Approved | RICHARD DOCKUS |
| Final | 8/23/2022 | OK to Issue CofO | RICHARD DOCKUS |