16921 W TULSA ST 91344

Certificate Information: 16921 W TULSA ST 91344

Application / Permit
20014-20000-02356
Plan Check / Job No.
B20VN07613
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
25' x 25'-3" ADDITION TO AND CONVERT (E) DETACHED GARAGE INTO A (N) ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33 (c)-(d); ALL WORK PER WFPP.
Permit Issued
Issued on 11/18/2021
Issuing Office
Current Status
CofO Issued on 8/2/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/5/2020 APPLICANT
Assigned to Plan Check Engineer 6/10/2020 SEAN SHAHMIRI
Corrections Issued 6/12/2020 SEAN SHAHMIRI
Building Plans Picked Up 6/15/2020 APPLICANT
Plan Check Approved 11/15/2021 SEAN SHAHMIRI
Issued 11/18/2021 APPLICANT
CofO in Progress 8/1/2022 JAVIER RAMOS JR
CofO Issued 8/2/2022 RONALD MYRICK
Permit Finaled 8/2/2022 RONALD MYRICK

Permit Application Clearance Information

Address approval Cleared 6/24/2020 GABRIEL ROBLES
Eng Process Fee Ord 176,300 Cleared 6/24/2020 GABRIEL ROBLES
Sewer availability Cleared 6/24/2020 GABRIEL ROBLES
Construction within easement Cleared 7/16/2020 WALTER RAMIREZ
Low Impact Development Cleared 6/1/2021 YVAINNE GALSIM
Roof/Waste drainage to street Cleared 6/1/2021 ABDULLAH SADOZAI

Contact Information

Contractor Owner-Builder       ,

Inspector Information

CHRISTOPHER ROJAS, (818) 374-1160 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 1/31/2022 Conditional Approval JESUS RODRIGUEZ
PLUMBING-Rough 2/17/2022 Approved JESUS RODRIGUEZ
Footing/Foundation/Slab 2/22/2022 Corrections Issued RAUL OLAGI
Footing/Foundation/Slab 3/7/2022 Corrections Issued MICHAEL TEMPLE
BUILDING-Rough-Frame 3/9/2022 Corrections Issued MICHAEL TEMPLE
Footing/Foundation/Slab 3/9/2022 Approved MICHAEL TEMPLE
Sewer 3/22/2022 Approved JENNIFER RABUCHIN
Gas Test 3/30/2022 Partial Approval JAVIER RAMOS JR
Underground Mechanical 3/30/2022 Approved JAVIER RAMOS JR
BUILDING-Rough-Frame 4/19/2022 Not Ready for Inspection JAVIER RAMOS JR
ELECTRICAL-Rough 4/19/2022 Corrections Issued JAVIER RAMOS JR
Floor/Roof Diaphrgm/Shear Wall 4/19/2022 Partial Approval JAVIER RAMOS JR
Green Building Rough 4/19/2022 Not Ready for Inspection JAVIER RAMOS JR
HVAC-Rough 4/19/2022 Corrections Issued JAVIER RAMOS JR
PLUMBING-Rough 4/19/2022 Approved JAVIER RAMOS JR
HVAC-Rough 4/21/2022 Approved JAVIER RAMOS JR
Insulation 4/21/2022 Partial Approval JAVIER RAMOS JR
BUILDING-Rough-Frame 4/25/2022 Partial Approval JAVIER RAMOS JR
Floor/Roof Diaphrgm/Shear Wall 4/25/2022 Approved JAVIER RAMOS JR
Green Building Rough 4/25/2022 Partial Approval JAVIER RAMOS JR
Insulation 4/25/2022 Partial Approval JAVIER RAMOS JR
Interior/Exterior Lathing 4/25/2022 Partial Approval JAVIER RAMOS JR
Shower Pan 4/25/2022 Approved JAVIER RAMOS JR
Drywall Nailing 4/28/2022 Partial Approval JAVIER RAMOS JR
BUILDING-Rough-Frame 5/25/2022 Approved JAVIER RAMOS JR
Drywall Nailing 5/25/2022 Approved JAVIER RAMOS JR
Green Building Rough 5/25/2022 Approved JAVIER RAMOS JR
Insulation 5/25/2022 Approved JAVIER RAMOS JR
Underground Mechanical 5/25/2022 Approved JAVIER RAMOS JR
Final 6/14/2022 Corrections Issued JAVIER RAMOS JR
Green Building Final 6/14/2022 Not Ready for Inspection JAVIER RAMOS JR
SGSOV-Seismic Gas S/O Valve 6/14/2022 SGSOV Not Ready JAVIER RAMOS JR
Smoke Detectors 6/14/2022 Approved JAVIER RAMOS JR
ELECTRICAL-Rough 6/24/2022 Approved JAVIER RAMOS JR
Final 6/24/2022 Corrections Issued JAVIER RAMOS JR
SGSOV-Seismic Gas S/O Valve 6/29/2022 SGSOV Approved JAVIER RAMOS JR
Final 7/18/2022 OK to Issue CofO JAVIER RAMOS JR
Green Building Final 7/18/2022 Approved JAVIER RAMOS JR