3362 W MADERA AVE 90039

Certificate Information: 3362 W MADERA AVE 90039

Application / Permit
20014-20000-02309
Plan Check / Job No.
B20VN07463
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ADD 14'-6" X 23'-6" FOR NEW BEDROOM/BATHROOM/CLOSET TO AN (E) 1-STORY SFD. ALL WORK PER ENGINEERING.
Permit Issued
Issued on 4/21/2023
Issuing Office
Valley
Current Status
CofO Issued on 8/5/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/5/2020 APPLICANT
Assigned to Plan Check Engineer 6/11/2020 JENNIFER LEE
Corrections Issued 6/11/2020 JENNIFER LEE
Plan Check Approved 6/25/2020 JENNIFER LEE
Issued 4/21/2023 APPLICANT
CofO in Progress 8/1/2024 THOMAS LOGRASSO
CofO Issued 8/5/2024 DEROLD HAUFF
Permit Finaled 8/5/2024 DEROLD HAUFF

Permit Application Clearance Information

Roof/Waste drainage to street Cleared 6/24/2020 WALLIE JONG
Sewer availability Cleared 6/24/2020 WALLIE JONG
Eng Process Fee Ord 176,300 Cleared 6/26/2020 JOHN TRIANTAFYLLOS

Contact Information

Contractor Group Heritage Inc The; Lic. No.: 833713-B 10061 RIVERSIDE DRIVE #889      TOLUCA LAKE, CA 91602
Engineer Sabzehzar,, Habib; Lic. No.: C50442 8180 N PRICE AVE      FRESNO, CA 93720

Inspector Information

NICHOLAS LOPEZ, (213) 202-3224 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/7/2023 Corrections Issued HAMIK HARTOUNIAN
Floor/Roof Diaphrgm/Shear Wall 7/14/2023 No Access for Inspection HAMIK HARTOUNIAN
PLUMBING-Rough 10/20/2023 Corrections Issued HAMIK HARTOUNIAN
HVAC-Rough 11/28/2023 Partial Approval HAMIK HARTOUNIAN
PLUMBING-Rough 11/28/2023 Approved HAMIK HARTOUNIAN
BUILDING-Rough-Frame 12/13/2023 Not Ready for Inspection HAMIK HARTOUNIAN
ELECTRICAL-Rough 12/13/2023 Approved HAMIK HARTOUNIAN
Green Building Rough 12/13/2023 Corrections Issued HAMIK HARTOUNIAN
BUILDING-Rough-Frame 1/11/2024 Not Ready for Inspection HAMIK HARTOUNIAN
Green Building Rough 1/11/2024 Approved HAMIK HARTOUNIAN
Shower Pan 1/11/2024 Conditional Approval HAMIK HARTOUNIAN
BUILDING-Rough-Frame 1/17/2024 Approved HAMIK HARTOUNIAN
HVAC-Rough 1/17/2024 Approved HAMIK HARTOUNIAN
Interior/Exterior Lathing 1/17/2024 Partial Approval HAMIK HARTOUNIAN
Insulation 1/24/2024 Approved HAMIK HARTOUNIAN
Drywall Nailing 2/2/2024 Approved HAMIK HARTOUNIAN
Pre-Inspection 5/20/2024 Partial Inspection THOMAS LOGRASSO
Final 7/25/2024 Corrections Issued BRENDAN MORELLI
Footing/Foundation/Slab 7/25/2024 Approved BRENDAN MORELLI
Green Building Final 7/25/2024 Approved BRENDAN MORELLI
SGSOV-Seismic Gas S/O Valve 7/25/2024 SGSOV Not Required BRENDAN MORELLI
Smoke Detectors 7/25/2024 Approved BRENDAN MORELLI
Final 8/1/2024 OK to Issue CofO THOMAS LOGRASSO