10501-10503 N MARKLEIN AVE 91345
Certificate Information: 10501-10503 N MARKLEIN AVE 91345
- Application / Permit
- 20014-20000-01475
- Plan Check / Job No.
- B20VN05272
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- CONVERT (E) 17'-4" X 19'-4" ATTACHED GARAGE AND ADD 9'-1" X 20'-4" TO CREATE A (N) ACCESSORY DWELLING UNIT. ALL WORK PER WFPP.
- Permit Issued
- Issued on 5/21/2020
- Issuing Office
- Current Status
- CofO Issued on 4/24/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/16/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 4/16/2020 | RAPHAEL ROSAS |
| Corrections Issued | 4/17/2020 | RAPHAEL ROSAS |
| Plan Check Approved | 5/1/2020 | RAPHAEL ROSAS |
| Issued | 5/21/2020 | APPLICANT |
| CofO in Progress | 3/10/2021 | JENNIFER RABUCHIN |
| CofO Issued | 4/24/2021 | MICHAEL SMITH |
| Permit Finaled | 4/24/2021 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 4/21/2020 | JOHN LIN |
| Roof/Waste drainage to street | Cleared | 4/21/2020 | JOHN LIN |
| Eng Process Fee Ord 176,300 | Cleared | 4/22/2020 | JOHN LIN |
| Sewer availability | Cleared | 4/22/2020 | JOHN LIN |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JOHN COLEMAN, (818) 374-1179 | Office Hours: 7:00-8:00 AM MON-FRI |
| JENNIFER RABUCHIN, (818) 374-1179 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 7/21/2020 | Partial Approval | JENNIFER RABUCHIN |
| Deputy Drilled-In Anchors | 7/22/2020 | Partial Approval | JENNIFER RABUCHIN |
| Footing/Foundation/Slab | 7/23/2020 | Approved | JENNIFER RABUCHIN |
| Floor/Roof Diaphrgm/Shear Wall | 8/4/2020 | Partial Approval | MICHAEL TEMPLE |
| BUILDING-Rough-Frame | 8/18/2020 | Approved | KATHRYN BUTTERWORTH |
| ELECTRICAL-Rough | 8/18/2020 | Approved | KATHRYN BUTTERWORTH |
| Green Building Rough | 8/18/2020 | Approved | KATHRYN BUTTERWORTH |
| HVAC-Rough | 8/18/2020 | Approved | KATHRYN BUTTERWORTH |
| MERV13>=Rough | 8/18/2020 | Approved | KATHRYN BUTTERWORTH |
| PLUMBING-Rough | 8/18/2020 | Partial Approval | KATHRYN BUTTERWORTH |
| Insulation | 8/21/2020 | Approved | JENNIFER RABUCHIN |
| Interior/Exterior Lathing | 8/21/2020 | Partial Approval | JENNIFER RABUCHIN |
| Drywall Nailing | 8/27/2020 | Approved | JENNIFER RABUCHIN |
| Interior/Exterior Lathing | 9/14/2020 | Approved | JENNIFER RABUCHIN |
| Underground Mechanical | 9/14/2020 | Partial Approval | JENNIFER RABUCHIN |
| ELECTRICAL-Final | 2/25/2021 | Corrections Issued | JENNIFER RABUCHIN |
| Final | 2/25/2021 | Corrections Issued | JENNIFER RABUCHIN |
| Green Building Final | 2/25/2021 | Corrections Issued | JENNIFER RABUCHIN |
| HVAC-Final | 2/25/2021 | Corrections Issued | JENNIFER RABUCHIN |
| MERV13>=Final | 2/25/2021 | Corrections Issued | JENNIFER RABUCHIN |
| PLUMBING-Final | 2/25/2021 | Corrections Issued | JENNIFER RABUCHIN |
| SGSOV-Seismic Gas S/O Valve | 2/25/2021 | SGSOV Not Ready | JENNIFER RABUCHIN |
| Smoke Detectors | 2/25/2021 | Approved | JENNIFER RABUCHIN |
| ELECTRICAL-Final | 3/9/2021 | Approved | JENNIFER RABUCHIN |
| Final | 3/9/2021 | OK to Issue CofO | JENNIFER RABUCHIN |
| Green Building Final | 3/9/2021 | Approved | JENNIFER RABUCHIN |
| HVAC-Final | 3/9/2021 | Approved | JENNIFER RABUCHIN |
| MERV13>=Final | 3/9/2021 | Approved | JENNIFER RABUCHIN |
| PLUMBING-Final | 3/9/2021 | Approved | JENNIFER RABUCHIN |
| SGSOV-Seismic Gas S/O Valve | 3/9/2021 | SGSOV Approved | JENNIFER RABUCHIN |