2726 W GLASSELL ST 90026
Certificate Information: 2726 W GLASSELL ST 90026
- Application / Permit
- 20014-20000-01378
- Plan Check / Job No.
- B20VN05030
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- REMOVE 34SF PORTION OF EX. STORAGE; ADD 25 SF AND CONVERT GARAGE TO 20' x 24'11" ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d) . ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 12/1/2020
- Issuing Office
- Current Status
- CofO Issued on 3/7/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/31/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 4/7/2020 | JEFFREY TANGONAN |
| Corrections Issued | 4/7/2020 | JEFFREY TANGONAN |
| Building Plans Picked Up | 4/8/2020 | APPLICANT |
| Plan Check Approved | 11/13/2020 | JEFFREY TANGONAN |
| Issued | 12/1/2020 | APPLICANT |
| CofO in Progress | 10/13/2021 | ROBERT VORHIS |
| Permit Finaled | 3/7/2023 | DANIEL ORRANTE |
| CofO Issued | 3/7/2023 | DANIEL ORRANTE |
| Permit Finaled | 3/7/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Address approval | Cleared | 5/12/2020 | EMIL KYUPELYAN |
| Eng Process Fee Ord 176,300 | Cleared | 5/12/2020 | EMIL KYUPELYAN |
| Sewer availability | Cleared | 5/12/2020 | EMIL KYUPELYAN |
| Grading Pre-Inspection | Cleared | 5/13/2020 | PATRICK MISCHLICH |
| Construction near power lines | Cleared | 7/24/2020 | WALTER RAMIREZ |
Contact Information
| Engineer | Melchor,, Oscar Elias; Lic. No.: C76828 | 21243 VENTURA BLVD SUITE 119 WOODLAND HILLS, CA 91364 |
Inspector Information
| FREDDIE RIVERA, (213) 202-3437 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 12/24/2020 | Corrections Issued | ROBERT VORHIS |
| Footing/Foundation/Slab | 12/24/2020 | Not Ready for Inspection | ROBERT VORHIS |
| METHANE-Barrier | 12/24/2020 | Not Ready for Inspection | ROBERT VORHIS |
| METHANE-Subgrade | 12/24/2020 | Not Ready for Inspection | ROBERT VORHIS |
| Underground Mechanical | 12/24/2020 | Not Ready for Inspection | ROBERT VORHIS |
| Excavation/Setback/Form/Re-Bar | 12/31/2020 | Partial Approval | ROBERT VORHIS |
| Footing/Foundation/Slab | 12/31/2020 | Not Ready for Inspection | ROBERT VORHIS |
| METHANE-Barrier | 12/31/2020 | Not Ready for Inspection | ROBERT VORHIS |
| METHANE-Subgrade | 12/31/2020 | Not Ready for Inspection | ROBERT VORHIS |
| Underground Mechanical | 12/31/2020 | Partial Approval | ROBERT VORHIS |
| Floor/Roof Diaphrgm/Shear Wall | 2/17/2021 | Approved | ROBERT VORHIS |
| PLUMBING-Rough | 2/17/2021 | Approved | ROBERT VORHIS |
| BUILDING-Rough-Frame | 2/24/2021 | Approved | ROBERT VORHIS |
| Green Building Rough | 2/24/2021 | Approved | ROBERT VORHIS |
| METHANE-Rough | 2/24/2021 | Approved | ROBERT VORHIS |
| Insulation | 3/2/2021 | Approved | ROBERT VORHIS |
| Drywall Nailing | 3/8/2021 | Approved | ROBERT VORHIS |
| ELECTRICAL-Final | 4/15/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| Final | 4/15/2021 | Corrections Issued | KATHRYN BUTTERWORTH |
| Footing/Foundation/Slab | 4/15/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| Green Building Final | 4/15/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| HVAC-Final | 4/15/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| METHANE-Barrier | 4/15/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| METHANE-Subgrade | 4/15/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| PLUMBING-Final | 4/15/2021 | Approved | KATHRYN BUTTERWORTH |
| SGSOV-Seismic Gas S/O Valve | 4/15/2021 | SGSOV Not Ready | KATHRYN BUTTERWORTH |
| Smoke Detectors | 4/15/2021 | Approved | KATHRYN BUTTERWORTH |
| ELECTRICAL-Final | 4/26/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| Gas Test | 4/26/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| HVAC-Final | 4/26/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| PLUMBING-Final | 4/26/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| METHANE-Barrier | 4/28/2021 | Approved | ROBERT VORHIS |
| METHANE-Subgrade | 4/28/2021 | Approved | ROBERT VORHIS |
| SGSOV-Seismic Gas S/O Valve | 4/28/2021 | SGSOV Not Ready | ROBERT VORHIS |
| Final | 7/1/2021 | Corrections Issued | ROBERT VORHIS |
| Footing/Foundation/Slab | 7/1/2021 | Approved | ROBERT VORHIS |
| Green Building Final | 7/1/2021 | Approved | ROBERT VORHIS |
| SGSOV-Seismic Gas S/O Valve | 7/1/2021 | SGSOV Approved | ROBERT VORHIS |
| Final | 10/6/2021 | Conditional Approval | ROBERT VORHIS |