14832 W COVELLO ST 91405
Certificate Information: 14832 W COVELLO ST 91405
- Application / Permit
- 20014-20000-00372
- Plan Check / Job No.
- B20VN01424
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT EXISTING DETACHED GARAGE (360 SF) TO ACCESSORY DEWLLING UNIT AND ADD FLOOR AREA PER WOOD FRAME PRESCRIPTIVE PROVISION (1,200 SF max per Ordinance, LAMC 12.22 A.33 (c)-(d))
- Permit Issued
- Issued on 11/3/2021
- Issuing Office
- Current Status
- CofO Issued on 5/31/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/28/2020 | APPLICANT |
| Green Plans Picked Up | 2/27/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 3/5/2020 | AUNG SOE |
| Corrections Issued | 3/9/2020 | AUNG SOE |
| Quality Review Completed | 3/10/2020 | QUAN NGHIEM |
| Building Plans Picked Up | 3/18/2020 | APPLICANT |
| Applicant returned to address corrections | 8/18/2020 | AUNG SOE |
| Applicant returned to address corrections | 8/20/2020 | AUNG SOE |
| Applicant returned to address corrections | 11/23/2020 | AUNG SOE |
| Applicant returned to address corrections | 9/29/2021 | AUNG SOE |
| Plan Check Approved | 10/26/2021 | AUNG SOE |
| Issued | 11/3/2021 | APPLICANT |
| CofO in Progress | 5/17/2022 | JOHN HAYES |
| CofO Issued | 5/31/2022 | MICHAEL SMITH |
| Permit Finaled | 5/31/2022 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 4/3/2020 | GUILLERMO PETRA |
| Permit | Cleared | 4/3/2020 | GUILLERMO PETRA |
| Eng Process Fee Ord 176,300 | Cleared | 4/6/2020 | ROSE MARIE SMITH |
| Sewer availability | Cleared | 4/6/2020 | ROSE MARIE SMITH |
| Green Code | Cleared | 7/29/2020 | AARON COSTA |
| Trees in Parkway | Cleared | 3/17/2021 | JOHN KIM |
| Low Impact Development | Cleared | 8/17/2021 | YVAINNE GALSIM |
| Roof/Waste drainage to street | Cleared | 10/18/2021 | ABDULLAH SADOZAI |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 11/8/2021 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 11/24/2021 | Partial Approval | MICHEL ABAJAN |
| Underground Mechanical | 11/24/2021 | Partial Inspection | MICHEL ABAJAN |
| Excavation/Setback/Form/Re-Bar | 12/1/2021 | Partial Inspection | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 12/3/2021 | Approved | GREGG CUMMINGS |
| Footing/Foundation/Slab | 12/3/2021 | Approved | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 12/16/2021 | Partial Approval | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 12/22/2021 | Partial Approval | MATT KELLERMAN |
| ELECTRICAL-Rough | 12/27/2021 | Approved | GREGG CUMMINGS |
| Green Building Rough | 12/27/2021 | Approved | GREGG CUMMINGS |
| HVAC-Rough | 12/27/2021 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 12/27/2021 | Approved | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 12/29/2021 | Corrections Issued | WILLIAM WREN |
| BUILDING-Rough-Frame | 1/4/2022 | Corrections Issued | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 1/10/2022 | Approved | GREGG CUMMINGS |
| Interior/Exterior Lathing | 1/10/2022 | Partial Approval | GREGG CUMMINGS |
| Sewer | 1/10/2022 | Approved | GREGG CUMMINGS |
| Insulation | 1/19/2022 | Approved | RYAN SALAZAR |
| Interior/Exterior Lathing | 1/19/2022 | Not Ready for Inspection | RYAN SALAZAR |
| Drywall Nailing | 1/24/2022 | Approved | CHRISTOPHER DELLEFIELD |
| Shower Pan | 1/27/2022 | Approved | GREGG CUMMINGS |
| Interior/Exterior Lathing | 1/31/2022 | Approved | WILLIAM WREN |
| Gas Test | 2/9/2022 | Partial Approval | GREGG CUMMINGS |
| Gas Test | 2/16/2022 | Corrections Issued | GREGG CUMMINGS |
| Gas Test | 2/22/2022 | Approved | GREGG CUMMINGS |
| Underground Mechanical | 2/22/2022 | Partial Approval | GREGG CUMMINGS |
| ELECTRICAL-Final | 3/14/2022 | Not Ready for Inspection | GREGG CUMMINGS |
| Final | 3/14/2022 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 3/14/2022 | Approved | GREGG CUMMINGS |
| HVAC-Final | 3/14/2022 | Not Ready for Inspection | GREGG CUMMINGS |
| PLUMBING-Final | 3/14/2022 | Not Ready for Inspection | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 3/14/2022 | SGSOV Approved | GREGG CUMMINGS |
| Smoke Detectors | 3/14/2022 | Approved | GREGG CUMMINGS |
| Final | 5/4/2022 | Corrections Issued | DAVID MATSON |
| Final | 5/13/2022 | OK to Issue CofO | JOHN HAYES |