11211 W LAURIE DR 91604
Certificate Information: 11211 W LAURIE DR 91604
- Application / Permit
- 20014-20000-00325
- Plan Check / Job No.
- B20VN01246
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- (1 OF 3)PROPOSED 15'-0.5" X 51'-11.5"(622.27 SF), 11'-5.5" X 9'-4"(85.66 SF), AND 2'-11"' X 20'-1.5"(38.27 SF) IRREGULAR SHAPED ADDITIONS TO (E) SFD. CONVERT (83 SF) PORTION OF GARAGE TO SFD. REMODEL (E) SFD AND INCREASE CEILING HEIGHT AT LIVING (110 SF). NFPA 13D FIRE SPRINKLERS THROUGHOUT.
- Permit Issued
- Issued on 4/28/2022
- Issuing Office
- Current Status
- CofO Issued on 12/31/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/24/2020 | APPLICANT |
| Green Plans Picked Up | 2/5/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 2/20/2020 | RAPHAEL ROSAS |
| Corrections Issued | 2/24/2020 | RAPHAEL ROSAS |
| Quality Review Completed | 3/20/2020 | CHON CHIO KUO |
| Applicant returned to address corrections | 1/11/2022 | RAPHAEL ROSAS |
| Building Plans Picked Up | 1/11/2022 | APPLICANT |
| Applicant returned to address corrections | 3/25/2022 | RAPHAEL ROSAS |
| Plan Check Approved | 4/12/2022 | RAPHAEL ROSAS |
| Issued | 4/28/2022 | APPLICANT |
| CofO in Progress | 11/19/2025 | CHRISTOPHE COCHRAN |
| Permit Finaled | 12/31/2025 | RUBEN SALAS |
| CofO Issued | 12/31/2025 | RUBEN SALAS |
| Permit Finaled | 12/31/2025 | RUBEN SALAS |
Permit Application Clearance Information
| BHO/Hillside ordinance | Cleared | 7/10/2020 | GUILLERMO PETRA |
| BHO/Hillside ordinance | Cleared | 10/1/2020 | JOHN TRIANTAFYLLOS |
| Eng Process Fee Ord 176,300 | Cleared | 10/2/2020 | JOHN TRIANTAFYLLOS |
| Sewer availability | Cleared | 10/2/2020 | JOHN TRIANTAFYLLOS |
| Green Code | Cleared | 10/28/2020 | DAVID MATSON |
| Distance to fire station | Cleared | 12/9/2020 | JEREMY CARTER |
| Hydrant and Access approval | Cleared | 12/17/2020 | MATTHEW CRAIG |
| Low Impact Development | Cleared | 1/13/2021 | ANDRES COVARRUBIAS |
| Roof/Waste drainage to street | Cleared | 4/29/2021 | JOHN TRIANTAFYLLOS |
| BHO/Hillside ordinance | Cleared | 12/17/2021 | JOHN LIN |
| Miscellaneous | Cleared | 12/17/2021 | OLGA AYALA |
| Permit | Cleared | 12/17/2021 | JOHN LIN |
| Specific Plan | Cleared | 12/17/2021 | OLGA AYALA |
| ZI | Cleared | 12/17/2021 | OLGA AYALA |
| GPI Written Notices | Cleared | 4/12/2022 | RAPHAEL ROSAS |
| Grading Pre-Inspection | Cleared | 4/12/2022 | RAPHAEL ROSAS |
Contact Information
| Contractor | Csi Building Inc; Lic. No.: 1067948-B | 261 E COLORADO BLVD STE 212 PASADENA, CA 91101 |
| Engineer | Melchor,, Oscar Elias; Lic. No.: C76828 | 21243 VENTURA BLVD SUITE 119 WOODLAND HILLS, CA 91364 |
| Engineer | Tsai,, Steve Shi-Shen; Lic. No.: GE2268 | 1545 VICTORY BLVD GLENDALE, CA 91201 |
| Geologist | Termeer,, Benjamin R; Lic. No.: EG2687 | 1545 VICTORY BLVD 2ND FL GLENDALE, CA 91201 |
Inspector Information
| CHRISTOPHE COCHRAN, (818) 374-1165 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 8/10/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Piling/Pier/Caisson | 8/10/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Piling/Pier/Caisson | 8/15/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Pre-Inspection | 8/15/2022 | Approved | CHRISTOPHE COCHRAN |
| Excavation/Setback/Form/Re-Bar | 9/13/2022 | Partial Approval | JOHN HAYES |
| Piling/Pier/Caisson | 9/13/2022 | Partial Approval | JOHN HAYES |
| Reinforced Concrete Frame | 9/23/2022 | Partial Approval | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 5/17/2023 | Corrections Issued | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 5/24/2023 | Partial Approval | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 6/22/2023 | Corrections Issued | CHRISTOPHE COCHRAN |
| Excavation/Setback/Form/Re-Bar | 7/19/2023 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 7/19/2023 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 8/10/2023 | Approved | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 9/27/2023 | Corrections Issued | CHRISTOPHE COCHRAN |
| Sewer | 9/27/2023 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Insulation | 10/26/2023 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 10/26/2023 | Partial Approval | CHRISTOPHE COCHRAN |
| Wood Frame | 10/26/2023 | Partial Approval | CHRISTOPHE COCHRAN |
| Insulation | 10/31/2023 | Partial Approval | CHRISTOPHE COCHRAN |
| Floor/Roof Diaphrgm/Shear Wall | 11/6/2023 | Partial Approval | CHRISTOPHE COCHRAN |
| Pre-Inspection | 11/6/2023 | Approved | CHRISTOPHE COCHRAN |
| Excavation/Setback/Form/Re-Bar | 2/29/2024 | Approved | CHRISTOPHE COCHRAN |
| BUILDING-Rough-Frame | 3/20/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| Wood Frame | 3/20/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| Deputy Wood Construction | 5/17/2024 | Conditional Approval | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 5/20/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| Floor/Roof Diaphrgm/Shear Wall | 5/20/2024 | Approved | CHRISTOPHE COCHRAN |
| Green Building Rough | 5/20/2024 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Wood Frame | 5/20/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| ELECTRICAL-Rough | 7/3/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 7/3/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| BUILDING-Rough-Frame | 7/18/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| ELECTRICAL-Rough | 7/18/2024 | Approved | CHRISTOPHE COCHRAN |
| Green Building Rough | 7/18/2024 | Approved | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 7/18/2024 | Approved | CHRISTOPHE COCHRAN |
| Wood Frame | 7/18/2024 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| BUILDING-Rough-Frame | 7/22/2024 | Approved | CHRISTOPHE COCHRAN |
| Insulation | 7/26/2024 | Approved | CHRISTOPHE COCHRAN |
| Drywall Nailing | 10/23/2024 | Approved | CHRISTOPHE COCHRAN |
| Shower Pan | 10/24/2024 | Approved | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 12/18/2024 | Approved | CHRISTOPHE COCHRAN |
| ELECTRICAL-Final | 3/4/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Grounding or Bonding | 3/4/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 3/19/2025 | Partial Inspection | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 3/24/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| ELECTRICAL-Final | 6/20/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Pre-Gunite | 6/20/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| ELECTRICAL-Final | 7/21/2025 | No Access for Inspection | CHRISTOPHE COCHRAN |
| Grounding or Bonding | 7/21/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Final | 10/21/2025 | Corrections Issued | CHRISTOPHE COCHRAN |
| Green Building Final | 10/21/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| SGSOV-Seismic Gas S/O Valve | 10/21/2025 | SGSOV Approved | CHRISTOPHE COCHRAN |
| Service/Power Release | 10/21/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Smoke Detectors | 10/21/2025 | Approved | CHRISTOPHE COCHRAN |
| Final | 10/28/2025 | Corrections Issued | CHRISTOPHE COCHRAN |
| Green Building Final | 10/28/2025 | Approved | CHRISTOPHE COCHRAN |
| Service/Power Release | 10/28/2025 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Final | 11/19/2025 | OK to Issue CofO | CHRISTOPHE COCHRAN |
| Pre-Inspection | 11/19/2025 | Approved | CHRISTOPHE COCHRAN |