4006 S 2ND AVE 90008
Certificate Information: 4006 S 2ND AVE 90008
- Application / Permit
- 20014-10002-04933
- Plan Check / Job No.
- B23LA20629
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- SUPPLEMENTAL TO 20014-10001-04933 TO REVISE PLAN TO INCREASE SIZE OF ADDITION. EXTRA BEDROOM AND BATH. RELOCATE LAUNDRY ROOM
- Permit Issued
- Issued on 12/28/2023
- Issuing Office
- Current Status
- Permit Finaled on 7/17/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/31/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 11/2/2023 | SINA KHOSRAVI |
| Corrections Issued | 11/7/2023 | SINA KHOSRAVI |
| Quality Review Completed | 11/8/2023 | KEN GILL |
| Building Plans Picked Up | 11/9/2023 | APPLICANT |
| Applicant returned to address corrections | 12/21/2023 | SINA KHOSRAVI |
| Plan Check Approved | 12/28/2023 | SINA KHOSRAVI |
| Issued | 12/28/2023 | APPLICANT |
| Permit Finaled | 7/16/2024 | CRAIG DAVIS |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 11/13/2023 | TREVOR QUAN |
| Eng Process Fee Ord 176,300 | Cleared | 11/14/2023 | TREVOR QUAN |
| Sewer availability | Cleared | 11/14/2023 | TREVOR QUAN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 60 VIA CARATAMA SAN CLEMENTE, CA 92673 |
Inspector Information
| LUIS CASTRO, (213) 202-3436 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 1/18/2024 | Not Ready for Inspection | ANTHONY EGSON |
| PLUMBING-Rough | 1/24/2024 | Partial Approval | ANTHONY EGSON |
| Sewer | 1/24/2024 | Approved | ANTHONY EGSON |
| Excavation/Setback/Form/Re-Bar | 1/26/2024 | Approved | ALIZAH MAYAGOITIA |
| Floor/Roof Diaphrgm/Shear Wall | 2/13/2024 | Partial Approval | BRENDAN MORELLI |
| ELECTRICAL-Rough | 3/19/2024 | Approved | ANTHONY EGSON |
| Interior/Exterior Lathing | 3/19/2024 | Corrections Issued | ANTHONY EGSON |
| ELECTRICAL-Rough | 3/29/2024 | Approved | ANTHONY EGSON |
| Gas Test | 3/29/2024 | Partial Approval | ANTHONY EGSON |
| Interior/Exterior Lathing | 3/29/2024 | Not Ready for Inspection | ANTHONY EGSON |
| Underground Mechanical | 3/29/2024 | Corrections Issued | ANTHONY EGSON |
| BUILDING-Rough-Frame | 4/2/2024 | Corrections Issued | ANTHONY EGSON |
| Green Building Rough | 4/2/2024 | Not Ready for Inspection | ANTHONY EGSON |
| Underground Mechanical | 4/2/2024 | Not Ready for Inspection | ANTHONY EGSON |
| Interior/Exterior Lathing | 4/19/2024 | Approved | ANTHONY EGSON |
| PLUMBING-Rough | 4/19/2024 | Partial Approval | ANTHONY EGSON |
| Wood Frame | 4/19/2024 | Approved | ANTHONY EGSON |
| Insulation | 5/3/2024 | Approved | JOSH MEISTER |
| Underground Mechanical | 5/3/2024 | Approved | JOSH MEISTER |
| Drywall Nailing | 5/9/2024 | Approved | ANTHONY EGSON |
| ELECTRICAL-Final | 7/11/2024 | Approved | ANTHONY EGSON |
| Final | 7/11/2024 | Corrections Issued | ANTHONY EGSON |
| Footing/Foundation/Slab | 7/11/2024 | Approved | ANTHONY EGSON |
| Green Building Final | 7/11/2024 | Not Ready for Inspection | ANTHONY EGSON |
| Green Building Rough | 7/11/2024 | Approved | ANTHONY EGSON |
| HVAC-Final | 7/11/2024 | Approved | ANTHONY EGSON |
| PLUMBING-Final | 7/11/2024 | Approved | ANTHONY EGSON |
| Smoke Detectors | 7/11/2024 | No Access for Inspection | ANTHONY EGSON |
| BUILDING-Rough-Frame | 7/16/2024 | Approved | CRAIG DAVIS |
| Final | 7/16/2024 | Permit Finaled | CRAIG DAVIS |
| Green Building Final | 7/16/2024 | Approved | CRAIG DAVIS |
| HVAC-Final | 7/16/2024 | Approved | CRAIG DAVIS |
| Smoke Detectors | 7/16/2024 | Approved | CRAIG DAVIS |