2053 W LAS COLINAS AVE 90041
Certificate Information: 2053 W LAS COLINAS AVE 90041
- Application / Permit
- 20014-10000-05444
- Plan Check / Job No.
- B20LA22769
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ADDITION (15.83FT X 21FT, 332 SQFT) AND MAJOR REMODELREMODEL (NEW BED, BATH AND CLOSET) WITH (N) TRELLIS ( 12.25 FT X 21 FT, 253 SQFT) TO (E) ONE STORY SFD. SEE COMMENT.
- Permit Issued
- Issued on 8/16/2021
- Issuing Office
- Current Status
- CofO Issued on 4/19/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/9/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 12/17/2020 | SAMUEL GONZALEZ |
| Corrections Issued | 12/18/2020 | SAMUEL GONZALEZ |
| Applicant returned to address corrections | 7/5/2021 | TSE MING HUANG |
| Plan Check Approved | 7/29/2021 | TSE MING HUANG |
| Building Plans Picked Up | 8/4/2021 | APPLICANT |
| Issued | 8/16/2021 | APPLICANT |
| CofO in Progress | 4/9/2022 | CRAIG VAUGHAN |
| Permit Finaled | 4/19/2022 | DEROLD HAUFF |
| CofO Issued | 4/19/2022 | DEROLD HAUFF |
| Permit Finaled | 4/19/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Sewer availability | Cleared | 1/14/2021 | RENZ SORIANO |
| Eng Process Fee Ord 176,300 | Cleared | 1/19/2021 | RENZ SORIANO |
| Low Impact Development | Cleared | 6/10/2021 | JORGE MEJIA LEMUS |
| Roof/Waste drainage to street | Cleared | 6/11/2021 | THAN WIN |
| Grading Pre-Inspection | Cleared | 6/15/2021 | BRIAN MILLER |
Contact Information
| Contractor | Rebuilt Homes Inc; Lic. No.: 1063540-B | 2201 N LAKEWOOD BLVD STE D643 LONG BEACH, CA 90815 |
| Engineer | Gonzalez,, Felix Bolivar; Lic. No.: C64738 | 14619 CATALINA AVE GARDENA, CA 90247 |
Inspector Information
| RONNIE MEDINA, (213) 469-5852 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 8/20/2021 | No Access for Inspection | CRAIG VAUGHAN |
| Footing/Foundation/Slab | 8/20/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| Footing/Foundation/Slab | 8/25/2021 | Approved | CRAIG VAUGHAN |
| Excavation/Setback/Form/Re-Bar | 8/27/2021 | Approved | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 9/7/2021 | Partial Approval | CRAIG VAUGHAN |
| Green Building Rough | 9/7/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| Service/Power Release | 10/7/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 10/8/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 10/8/2021 | Corrections Issued | CRAIG VAUGHAN |
| Green Building Rough | 10/8/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| HVAC-Rough | 10/8/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| PLUMBING-Rough | 10/8/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 10/13/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| HVAC-Rough | 10/13/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| PLUMBING-Rough | 10/13/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| Service/Power Release | 10/13/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 10/15/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 10/15/2021 | Partial Approval | CRAIG VAUGHAN |
| Floor/Roof Diaphrgm/Shear Wall | 10/15/2021 | Not Ready for Inspection | CRAIG VAUGHAN |
| Green Building Rough | 10/15/2021 | Approved | CRAIG VAUGHAN |
| HVAC-Rough | 10/15/2021 | Partial Approval | CRAIG VAUGHAN |
| PLUMBING-Rough | 10/15/2021 | Approved | CRAIG VAUGHAN |
| Wood Frame | 10/15/2021 | No Access for Inspection | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 10/21/2021 | Approved | CRAIG VAUGHAN |
| HVAC-Rough | 10/21/2021 | Approved | CRAIG VAUGHAN |
| Special/Order Compliance | 10/21/2021 | Approved | HECTOR ALIKHAN |
| Wood Frame | 10/21/2021 | Approved | CRAIG VAUGHAN |
| Insulation | 10/28/2021 | Approved | CRAIG VAUGHAN |
| Interior/Exterior Lathing | 10/28/2021 | Partial Approval | CRAIG VAUGHAN |
| Drywall Nailing | 11/22/2021 | Approved | CRAIG VAUGHAN |
| Interior/Exterior Lathing | 11/22/2021 | Approved | CRAIG VAUGHAN |
| Special/Order Compliance | 11/24/2021 | Partial Inspection | AMY COLIN |
| Wood Frame | 12/7/2021 | Approved | CRAIG VAUGHAN |
| ELECTRICAL-Final | 2/24/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| Final | 2/24/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| Green Building Final | 2/24/2022 | Approved | CRAIG VAUGHAN |
| PLUMBING-Final | 2/24/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| SGSOV-Seismic Gas S/O Valve | 2/24/2022 | SGSOV Not Ready | CRAIG VAUGHAN |
| Smoke Detectors | 2/24/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| ELECTRICAL-Final | 3/7/2022 | Corrections Issued | CRAIG VAUGHAN |
| Service/Power Release | 3/7/2022 | Approved | CRAIG VAUGHAN |
| Final | 3/30/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| SGSOV-Seismic Gas S/O Valve | 3/30/2022 | SGSOV Approved | CRAIG VAUGHAN |
| Smoke Detectors | 3/30/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| Final | 4/4/2022 | Corrections Issued | CRAIG VAUGHAN |
| Smoke Detectors | 4/4/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| Pre-Inspection | 4/6/2022 | Corrections Issued | CRAIG VAUGHAN |
| ELECTRICAL-Final | 4/8/2022 | Approved | CRAIG VAUGHAN |
| Final | 4/8/2022 | OK to Issue CofO | CRAIG VAUGHAN |
| Gas Test | 4/8/2022 | Approved | CRAIG VAUGHAN |
| HVAC-Final | 4/8/2022 | Approved | CRAIG VAUGHAN |
| PLUMBING-Final | 4/8/2022 | Approved | CRAIG VAUGHAN |