20133 W HAYNES ST 91306
Certificate Information: 20133 W HAYNES ST 91306
- Application / Permit
- 20014-10000-04898
- Plan Check / Job No.
- B20LA20590
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Ground floor addition to rear of (E) SFD with attached garage.
- Permit Issued
- Issued on 1/30/2021
- Issuing Office
- Current Status
- CofO Issued on 5/2/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/6/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 11/12/2020 | HELEN NGUYEN |
| Corrections Issued | 11/13/2020 | HELEN NGUYEN |
| Applicant returned to address corrections | 12/22/2020 | JOE VO |
| Plan Check Approved | 12/31/2020 | PRANITA SHAH |
| Issued | 1/30/2021 | APPLICANT |
| CofO in Progress | 4/27/2023 | ALEXANDER HANDY |
| Permit Finaled | 5/2/2023 | JOHN JANSON |
| CofO Issued | 5/2/2023 | JOHN JANSON |
| Permit Finaled | 5/2/2023 | JOHN JANSON |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 12/16/2020 | JOHN TRIANTAFYLLOS |
| Eng Process Fee Ord 176,300 | Cleared | 12/17/2020 | JOHN TRIANTAFYLLOS |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Zhong,, Raymond Meng; Lic. No.: M27635 | 2416 W VALLEY BLVD ALHAMBRA, CA 91803 |
Inspector Information
| DAVID FASTIGGI, (818) 774-4317 | Office Hours: 7:00-8:00 AM MON-FRI |
| ALEXANDER HANDY, (818) 774-4317 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 3/4/2022 | Conditional Approval | JESUS PINEDA |
| Excavation/Setback/Form/Re-Bar | 3/8/2022 | Approved | STEVEN BACK |
| Footing/Foundation/Slab | 3/8/2022 | Partial Approval | STEVEN BACK |
| BUILDING-Rough-Frame | 3/22/2022 | Order to Comply Issued | STEVEN BACK |
| FLOOD-Proofing Certificate | 3/22/2022 | Approved | STEVEN BACK |
| Footing/Foundation/Slab | 3/22/2022 | Approved | STEVEN BACK |
| Green Building Rough | 3/22/2022 | Not Ready for Inspection | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 3/29/2022 | Partial Approval | STEVEN BACK |
| Insulation | 3/29/2022 | Partial Approval | STEVEN BACK |
| BUILDING-Rough-Frame | 4/7/2022 | Not Ready for Inspection | TROY SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 4/7/2022 | Approved | TROY SANDERS |
| Green Building Rough | 4/7/2022 | Not Ready for Inspection | TROY SANDERS |
| ELECTRICAL-Rough | 4/20/2022 | Corrections Issued | STEVEN BACK |
| PLUMBING-Rough | 4/20/2022 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Rough | 4/22/2022 | Not Ready for Inspection | STEVEN BACK |
| Interior/Exterior Lathing | 4/22/2022 | Partial Approval | STEVEN BACK |
| PLUMBING-Rough | 4/22/2022 | Approved | STEVEN BACK |
| Shower Pan | 4/22/2022 | Approved | STEVEN BACK |
| ELECTRICAL-Rough | 5/12/2022 | Approved | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 5/12/2022 | Approved | STEVEN BACK |
| HVAC-Rough | 5/12/2022 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 5/13/2022 | Approved | STEVEN BACK |
| Insulation | 5/16/2022 | Not Ready for Inspection | STEVEN BACK |
| Green Building Rough | 5/18/2022 | Approved | STEVEN BACK |
| Insulation | 5/18/2022 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 5/18/2022 | Approved | STEVEN BACK |
| Drywall Nailing | 5/31/2022 | Approved | STEVEN BACK |
| Final | 10/14/2022 | Corrections Issued | STEVEN BACK |
| Green Building Final | 10/14/2022 | Approved | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 10/14/2022 | SGSOV Approved | STEVEN BACK |
| Smoke Detectors | 10/14/2022 | Approved | STEVEN BACK |
| ELECTRICAL-Final | 4/26/2023 | Approved | ALEXANDER HANDY |
| Final | 4/26/2023 | OK to Issue CofO | ALEXANDER HANDY |
| PLUMBING-Final | 4/26/2023 | Approved | ALEXANDER HANDY |