6029 1/2 W ELEANOR AVE 90038

Certificate Information: 6029 1/2 W ELEANOR AVE 90038

Application / Permit
20014-10000-03302
Plan Check / Job No.
B20LA13947
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERSION & ADDITIO OF DETACHED GARAGE INTO ADU PER LAMC 12.22A33 (c) & (d) Comply with Department Order effective date 03/11/2019.
Permit Issued
Issued on 10/19/2020
Issuing Office
Current Status
CofO Issued on 1/26/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/4/2020 APPLICANT
Assigned to Plan Check Engineer 8/27/2020 MAHNAZ NOURHASHEMI
Corrections Issued 9/2/2020 MAHNAZ NOURHASHEMI
Quality Review Completed 9/10/2020 JASON HEALEY
Building Plans Picked Up 9/14/2020 APPLICANT
Plan Check Approved 10/19/2020 MAHNAZ NOURHASHEMI
Issued 10/19/2020 APPLICANT
CofO in Progress 1/26/2021 JEFFREY CORPUZ
CofO Issued 1/26/2021 ARMOND GREGORYONA
Permit Finaled 1/26/2021 ARMOND GREGORYONA

Permit Application Clearance Information

Low Impact Development Cleared 9/25/2020 MARTIN FRAGOSO
Address approval Cleared 9/29/2020 CECILIO NAVARRO
Eng Process Fee Ord 176,300 Cleared 9/29/2020 CECILIO NAVARRO
Roof/Waste drainage to street Cleared 9/29/2020 CECILIO NAVARRO
Sewer availability Cleared 9/29/2020 CECILIO NAVARRO
ZI Cleared 9/30/2020 HERMINIGILDO AGUSTIN
Hydrant and Access approval Cleared 10/7/2020 KURT CORRAL

Contact Information

Contractor Owner-Builder       ,
Engineer Perez,, Thomas E; Lic. No.: C67549 1521 FRANZEN AVE      SANTA ANA, CA 92703

Inspector Information

EDMUND LUM, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
LUCIANO GAUNA, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
JAIME RIOS, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
ANDEY CHAPARRO, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
RYAN BARNES, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
PATRICK LIEBREGT, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
GLEN RAND, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
SHAWN ESHBACH, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI
GABRIEL HERRERA, (213) 252-3962 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Gas Test 11/2/2020 Approved JEFFREY CORPUZ
PLUMBING-Rough 11/2/2020 Partial Approval JEFFREY CORPUZ
Footing/Foundation/Slab 11/5/2020 Approved JEFFREY CORPUZ
Sewer 11/5/2020 Approved JEFFREY CORPUZ
BUILDING-Rough-Frame 11/16/2020 Not Ready for Inspection JEFFREY CORPUZ
Green Building Rough 11/16/2020 Not Ready for Inspection JEFFREY CORPUZ
BUILDING-Rough-Frame 11/23/2020 Approved JEFFREY CORPUZ
Floor/Roof Diaphrgm/Shear Wall 11/23/2020 Approved JEFFREY CORPUZ
Green Building Rough 11/23/2020 Approved JEFFREY CORPUZ
ELECTRICAL-Rough 11/30/2020 Approved JEFFREY CORPUZ
PLUMBING-Rough 11/30/2020 Approved JEFFREY CORPUZ
HVAC-Rough 12/1/2020 Approved JEFFREY CORPUZ
Insulation 12/1/2020 Approved JEFFREY CORPUZ
Drywall Nailing 12/3/2020 Approved JEFFREY CORPUZ
Interior/Exterior Lathing 12/3/2020 Approved JEFFREY CORPUZ
Final 1/25/2021 Partial Approval JEFFREY CORPUZ
Green Building Final 1/25/2021 Approved JEFFREY CORPUZ
SGSOV-Seismic Gas S/O Valve 1/25/2021 SGSOV Approved JEFFREY CORPUZ
Smoke Detectors 1/25/2021 Approved JEFFREY CORPUZ