5138 E RAPHAEL ST 90042
Certificate Information: 5138 E RAPHAEL ST 90042
- Application / Permit
- 20014-10000-02963
- Plan Check / Job No.
- B20LA12409
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- MAJOR REMODEL AND 1-STORY ADDITION, ADD OPEN TRELLIS . INTERIOR REMODEL TO EXISTING SINGLE FAMILY RESIDENCE. REFRAME REAR PORTION OF ROOF AS FLAT ROOF.
- Permit Issued
- Issued on 1/4/2021
- Issuing Office
- Current Status
- CofO Issued on 12/24/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/17/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/21/2020 | JESSE JIMENEZ |
| Corrections Issued | 7/21/2020 | JESSE JIMENEZ |
| Applicant returned to address corrections | 10/21/2020 | FERNANDO FLORES |
| Applicant returned to address corrections | 11/18/2020 | GEORGE ALVAREZ |
| Plan Check Approved | 11/20/2020 | GEORGE ALVAREZ |
| Issued | 1/4/2021 | APPLICANT |
| Building Plans Picked Up | 1/15/2021 | APPLICANT |
| CofO in Progress | 11/2/2022 | HAMIK HARTOUNIAN |
| Permit Finaled | 12/24/2022 | DEROLD HAUFF |
| CofO Issued | 12/24/2022 | DEROLD HAUFF |
| Permit Finaled | 12/24/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 9/28/2020 | BRIAN MILLER |
| Distance to fire station | Cleared | 10/29/2020 | KURT CORRAL |
| BHO/Hillside ordinance | Cleared | 10/30/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 10/30/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 10/30/2020 | ELAINE LEI |
| BHO/Hillside ordinance | Cleared | 10/30/2020 | ELAINE LEI |
| Eng Process Fee Ord 176,300 | Cleared | 10/30/2020 | ELAINE LEI |
| Roof/Waste drainage to street | Cleared | 10/30/2020 | ELAINE LEI |
Contact Information
| Contractor | Inzunza Builders Inc; Lic. No.: 1054458-B | 8413 CONKLIN ST DOWNEY, CA 90242 |
| Engineer | Nishimura,, Kentaro James; Lic. No.: C73821 | 5138 RAPHAEL ST LOS ANGELES, CA 90042 |
Inspector Information
| NICHOLAS LOPEZ, (213) 202-3224 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 2/1/2021 | Corrections Issued | HAMIK HARTOUNIAN |
| Deputy Drilled-In Anchors | 2/19/2021 | Conditional Approval | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 2/24/2021 | Partial Approval | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 3/3/2021 | Approved | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 3/31/2021 | Corrections Issued | HAMIK HARTOUNIAN |
| Green Building Rough | 3/31/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Wood Frame | 3/31/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 4/7/2021 | Off-Hour Fees Due | |
| Floor/Roof Diaphrgm/Shear Wall | 4/8/2021 | Approved | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 5/13/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 5/13/2021 | Partial Approval | HAMIK HARTOUNIAN |
| Green Building Rough | 5/13/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Deputy Wood Construction | 5/17/2021 | No Access for Inspection | ELMER BLAND |
| ELECTRICAL-Rough | 5/20/2021 | Conditional Approval | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 5/20/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 5/24/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Green Building Rough | 5/24/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| HVAC-Rough | 5/24/2021 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 6/1/2021 | Approved | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 6/4/2021 | Approved | HAMIK HARTOUNIAN |
| Floor/Roof Diaphrgm/Shear Wall | 6/4/2021 | Approved | HAMIK HARTOUNIAN |
| Shower Pan | 6/4/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| BUILDING-Rough-Frame | 6/10/2021 | Approved | HAMIK HARTOUNIAN |
| Green Building Rough | 6/10/2021 | Approved | HAMIK HARTOUNIAN |
| Interior/Exterior Lathing | 6/10/2021 | Partial Approval | HAMIK HARTOUNIAN |
| Shower Pan | 6/10/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Insulation | 6/17/2021 | Conditional Approval | HAMIK HARTOUNIAN |
| Interior/Exterior Lathing | 6/17/2021 | Approved | HAMIK HARTOUNIAN |
| Shower Pan | 6/17/2021 | Approved | HAMIK HARTOUNIAN |
| Drywall Nailing | 6/22/2021 | Approved | WILLIAM WREN |
| Underground Mechanical | 7/2/2021 | Partial Approval | HAMIK HARTOUNIAN |
| ELECTRICAL-Rough | 7/28/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| ELECTRICAL-Final | 8/2/2021 | Corrections Issued | HAMIK HARTOUNIAN |
| Service/Power Release | 8/2/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| ELECTRICAL-Final | 12/3/2021 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| HVAC-Final | 12/3/2021 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Final | 12/3/2021 | Approved | HAMIK HARTOUNIAN |
| Final | 8/10/2022 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Final | 10/5/2022 | No Access for Inspection | HAMIK HARTOUNIAN |
| Green Building Final | 10/5/2022 | No Access for Inspection | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 10/5/2022 | SGSOV Not Ready | HAMIK HARTOUNIAN |
| Smoke Detectors | 10/5/2022 | No Access for Inspection | HAMIK HARTOUNIAN |
| Final | 11/2/2022 | OK to Issue CofO | HAMIK HARTOUNIAN |
| Green Building Final | 11/2/2022 | Approved | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 11/2/2022 | SGSOV Approved | HAMIK HARTOUNIAN |
| Smoke Detectors | 11/2/2022 | Approved | HAMIK HARTOUNIAN |