8811 S WESTERN AVE 90047
Certificate Information: 8811 S WESTERN AVE 90047
- Application / Permit
- 20014-10000-02133
- Plan Check / Job No.
- B20LA09112
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- Commercial
- Primary Use
- (16) Retail
- Work Description
- EXTERIOR RENOVATION FOR EXITING 1-STORY COMMERICAL BUILDING WITH -RENOVATION OF EXISTING W-BEAM DECORATIVE FRAMES -ADDITION TO RETAIL SHOP (960SF) -RENOVATION OF EXISTING BULDING EXTERIOR WALL -ADDITION OF PARKING TO COMPLY WITH CITY CODE & ADA
- Permit Issued
- Issued on 7/8/2021
- Issuing Office
- Current Status
- CofO Issued on 5/3/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/26/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 6/18/2020 | JOHNNY WU |
| Corrections Issued | 7/8/2020 | JOHNNY WU |
| Disabled Access Plans Picked Up | 7/17/2020 | APPLICANT |
| Quality Review Completed | 7/22/2020 | KESETE HAREGOT |
| Building Plans Picked Up | 7/24/2020 | APPLICANT |
| Applicant returned to address corrections | 8/7/2020 | JOHNNY WU |
| Green Plans Picked Up | 9/30/2020 | APPLICANT |
| Applicant returned to address corrections | 12/1/2020 | JOHNNY WU |
| Plan Check Approved | 12/1/2020 | JOHNNY WU |
| Issued | 7/8/2021 | APPLICANT |
| CofO in Progress | 4/22/2022 | RUSSELL BONVOULOIR |
| Permit Finaled | 5/3/2022 | ERNESTO CORRAL |
| CofO Issued | 5/3/2022 | ERNESTO CORRAL |
| Permit Finaled | 5/3/2022 | ERNESTO CORRAL |
Permit Application Clearance Information
| Historic Resource Verification | Cleared | 7/28/2020 | MICAELA TORRES-GIL |
| "Q" conditions | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| "T" removal | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| Comm Cor/Mini-Mall | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| Comm Cor/Mini-Mall | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| Prkng lot landscape/Water mgmt | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| ZA Case | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| ZA Case | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| ZA Case | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| ZA Case | Cleared | 7/29/2020 | RUBEN VASQUEZ |
| Community Plan Implem. Overlay | Cleared | 8/3/2020 | KEVIN ARUCAN |
| Internal circulation | Cleared | 8/3/2020 | KEVIN ARUCAN |
| Construction near power lines | Cleared | 8/18/2020 | OSCAR CASTRO |
| Construction within easement | Cleared | 8/18/2020 | OSCAR CASTRO |
| Low Impact Development | Cleared | 8/19/2020 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 8/21/2020 | JEANIE LAM |
| Redevelopment Project Area | Cleared | 8/24/2020 | GRACIELA ACOSTA |
| Eng Process Fee Ord 176,300 | Cleared | 8/25/2020 | JEANIE LAM |
| Highway dedication | Cleared | 8/25/2020 | JEANIE LAM |
| Sewer availability | Cleared | 8/25/2020 | JEANIE LAM |
| Green Code | Cleared | 9/25/2020 | NEGAR NEJAD |
| DAS Clearance | Cleared | 10/1/2020 | CHOI YAN |
| ZA Case | Cleared | 10/29/2020 | HELEN JADALI |
Contact Information
| Architect | Kim,, Daniel Dongmyung; Lic. No.: C30563 | 9745 RESEDA BLVD # 29 NORTHRIDGE, CA 91324 |
| Contractor | Mac Construction Builders Inc; Lic. No.: 1065329-B | 4100 WILSHIRE BLVD #403 LOS ANGELES, CA 90010 |
| Engineer | Park,, Juntae; Lic. No.: C65104 | 3055 WILSHIRE BLVD 880 LOS ANGELES, CA 90010 |
Inspector Information
| PAUL BAZERKANIAN, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
| LUIS CCAMACHO, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
| ALAN MORELOS, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 9/3/2021 | Conditional Approval | LEOPOLDO MENDOZA |
| Footing/Foundation/Slab | 9/3/2021 | Partial Approval | LEOPOLDO MENDOZA |
| Deputy Steel/Welding | 9/7/2021 | Conditional Approval | LEOPOLDO MENDOZA |
| Deputy Drilled-In Anchors | 10/6/2021 | Conditional Approval | LEOPOLDO MENDOZA |
| Drywall Nailing | 10/13/2021 | Conditional Approval | DARRYL ARNOLD |
| Floor/Roof Diaphrgm/Shear Wall | 10/13/2021 | Conditional Approval | DARRYL ARNOLD |
| Wood Frame | 10/13/2021 | Corrections Issued | DARRYL ARNOLD |
| Floor/Roof Diaphrgm/Shear Wall | 10/29/2021 | Not Ready for Inspection | JOEY BUCHANAN |
| Interior/Exterior Lathing | 10/29/2021 | Partial Approval | JOEY BUCHANAN |
| Floor/Roof Diaphrgm/Shear Wall | 11/2/2021 | Partial Approval | RUSSELL BONVOULOIR |
| Deputy Steel/Welding | 11/30/2021 | Conditional Approval | DARRYL ARNOLD |
| Deputy Steel/Welding | 12/1/2021 | Conditional Approval | DARRYL ARNOLD |
| Deputy Steel/Welding | 12/2/2021 | Conditional Approval | DARRYL ARNOLD |
| Insulation | 12/8/2021 | Approved | RUSSELL BONVOULOIR |
| Drywall Nailing | 12/10/2021 | Conditional Approval | DARRYL ARNOLD |
| Drywall Nailing | 12/15/2021 | Approved | RUSSELL BONVOULOIR |
| T-Bar Ceiling | 12/21/2021 | Not Ready for Inspection | RUSSELL BONVOULOIR |
| T-Bar Ceiling | 12/28/2021 | Approved | RUSSELL BONVOULOIR |
| Final | 2/4/2022 | Not Ready for Inspection | DARRYL ARNOLD |
| Footing/Foundation/Slab | 2/4/2022 | Partial Approval | DARRYL ARNOLD |
| Green Building Final | 2/4/2022 | Conditional Approval | DARRYL ARNOLD |
| Green Building Rough | 2/4/2022 | Partial Approval | DARRYL ARNOLD |
| Reinforced Masonry Frame | 2/4/2022 | Partial Approval | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 2/4/2022 | SGSOV Not Ready | DARRYL ARNOLD |
| Smoke Detectors | 2/4/2022 | Corrections Issued | DARRYL ARNOLD |
| Final | 2/9/2022 | Conditional Approval | RUSSELL BONVOULOIR |
| Footing/Foundation/Slab | 2/9/2022 | Approved | RUSSELL BONVOULOIR |
| Green Building Final | 2/9/2022 | Approved | RUSSELL BONVOULOIR |
| Green Building Rough | 2/9/2022 | Approved | RUSSELL BONVOULOIR |
| Reinforced Masonry Frame | 2/9/2022 | Approved | RUSSELL BONVOULOIR |
| SGSOV-Seismic Gas S/O Valve | 2/9/2022 | SGSOV Approved | RUSSELL BONVOULOIR |
| Smoke Detectors | 2/9/2022 | Approved | RUSSELL BONVOULOIR |