1846 N LEMOYNE ST 90026

Certificate Information: 1846 N LEMOYNE ST 90026

Application / Permit
20014-10000-01364
Plan Check / Job No.
B20LA05807
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
REMODEL AND THREE STORIES ADDITION TO EXISTING SFD
Permit Issued
Issued on 1/18/2021
Issuing Office
Current Status
CofO Issued on 7/26/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 3/31/2020 APPLICANT
Assigned to Plan Check Engineer 4/9/2020 ARSALAN SHABESTARI
Corrections Issued 4/16/2020 ARSALAN SHABESTARI
Quality Review Completed 4/27/2020 HERNAN ARREOLA
Green Plans Picked Up 6/15/2020 APPLICANT
Applicant returned to address corrections 6/17/2020 ARSALAN SHABESTARI
Applicant returned to address corrections 8/31/2020 ARSALAN SHABESTARI
Building Plans Picked Up 9/4/2020 APPLICANT
Applicant returned to address corrections 12/22/2020 ARSALAN SHABESTARI
Plan Check Approved 1/7/2021 ARSALAN SHABESTARI
Issued 1/18/2021 APPLICANT
CofO in Progress 7/14/2023 THOMAS LOGRASSO
CofO Issued 7/26/2023 DEROLD HAUFF
Permit Finaled 7/26/2023 DEROLD HAUFF

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 5/28/2020 RENZ SORIANO
Sewer availability Cleared 5/28/2020 RENZ SORIANO
Green Code Cleared 6/12/2020 DONALD CRICHLOW
Hydrant and Access approval Cleared 8/20/2020 MATTHEW CRAIG
Low Impact Development Cleared 8/25/2020 ROBIN YAMADA
GPI Written Notices Cleared 12/21/2020 ARSALAN SHABESTARI
Grading Pre-Inspection Cleared 12/21/2020 ARSALAN SHABESTARI
Roof/Waste drainage to street Cleared 12/21/2020 RENZ SORIANO

Contact Information

Contractor Chung Nong Contractors; Lic. No.: 964739-B 933 LINDENCLIFF ST      TORRANCE, CA 90502
Engineer Lee,, Jack C; Lic. No.: GE2153 576 E LAMBERT RD      BREA, CA 92821
Engineer Yu,, Kunyoung; Lic. No.: C66880 22812 ERIEL AVE      TORRANCE, CA 90505

Inspector Information

HAMIK HARTOUNIAN, (213) 202-3275 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 5/19/2021 Conditional Approval JESUS PINEDA
Deputy Drilled-In Anchors 5/21/2021 Approved WILLIAM WREN
Footing/Foundation/Slab 11/1/2021 Corrections Issued THOMAS LOGRASSO
Pre-Inspection 2/17/2022 Partial Inspection THOMAS LOGRASSO
Footing/Foundation/Slab 2/25/2022 Partial Approval DANIEL GONZALEZ
PLUMBING-Rough 3/7/2022 Partial Approval THOMAS LOGRASSO
Footing/Foundation/Slab 3/11/2022 Approved THOMAS LOGRASSO
Deputy Drilled-In Anchors 4/12/2022 Conditional Approval THOMAS LOGRASSO
Floor/Roof Diaphrgm/Shear Wall 5/2/2022 Corrections Issued THOMAS LOGRASSO
Deputy Wood Construction 5/12/2022 Conditional Approval THOMAS LOGRASSO
Floor/Roof Diaphrgm/Shear Wall 5/16/2022 Partial Approval THOMAS LOGRASSO
Green Building Rough 5/16/2022 Not Ready for Inspection THOMAS LOGRASSO
Deputy Drilled-In Anchors 5/17/2022 Conditional Approval THOMAS LOGRASSO
Deputy Fireproofing 5/17/2022 Approved THOMAS LOGRASSO
Deputy Reinf. Concrete 5/17/2022 Conditional Approval THOMAS LOGRASSO
Deputy Drilled-In Anchors 5/18/2022 Conditional Approval THOMAS LOGRASSO
Deputy Fireproofing 5/18/2022 Conditional Approval THOMAS LOGRASSO
Deputy Reinf. Concrete 5/18/2022 Conditional Approval THOMAS LOGRASSO
Deputy Drilled-In Anchors 5/19/2022 Conditional Approval THOMAS LOGRASSO
Deputy Fireproofing 5/19/2022 Conditional Approval THOMAS LOGRASSO
Deputy Reinf. Concrete 5/19/2022 Conditional Approval THOMAS LOGRASSO
Deputy Drilled-In Anchors 5/20/2022 Conditional Approval THOMAS LOGRASSO
Deputy Fireproofing 5/20/2022 Conditional Approval THOMAS LOGRASSO
Deputy Reinf. Concrete 5/20/2022 Conditional Approval THOMAS LOGRASSO
Deputy Drilled-In Anchors 5/23/2022 Conditional Approval THOMAS LOGRASSO
Deputy Fireproofing 5/23/2022 Conditional Approval THOMAS LOGRASSO
Deputy Reinf. Concrete 5/23/2022 Conditional Approval THOMAS LOGRASSO
BUILDING-Rough-Frame 6/14/2022 Not Ready for Inspection THOMAS LOGRASSO
Green Building Rough 6/14/2022 Not Ready for Inspection THOMAS LOGRASSO
Floor/Roof Diaphrgm/Shear Wall 6/28/2022 Partial Approval THOMAS LOGRASSO
Green Building Rough 6/28/2022 Not Ready for Inspection THOMAS LOGRASSO
ELECTRICAL-Rough 7/8/2022 Approved THOMAS LOGRASSO
PLUMBING-Rough 7/8/2022 Not Ready for Inspection THOMAS LOGRASSO
Floor/Roof Diaphrgm/Shear Wall 7/13/2022 Corrections Issued THOMAS LOGRASSO
Green Building Rough 7/13/2022 Not Ready for Inspection THOMAS LOGRASSO
ELECTRICAL-Rough 8/1/2022 Approved THOMAS LOGRASSO
HVAC-Rough 8/1/2022 Not Ready for Inspection THOMAS LOGRASSO
PLUMBING-Rough 8/1/2022 Partial Approval THOMAS LOGRASSO
BUILDING-Rough-Frame 8/8/2022 Partial Approval THOMAS LOGRASSO
Green Building Rough 8/8/2022 Not Ready for Inspection THOMAS LOGRASSO
HVAC-Rough 8/8/2022 Approved THOMAS LOGRASSO
PLUMBING-Rough 8/8/2022 Approved THOMAS LOGRASSO
Insulation 8/11/2022 Conditional Approval THOMAS LOGRASSO
Drywall Nailing 8/18/2022 Conditional Approval THOMAS LOGRASSO
Interior/Exterior Lathing 11/1/2022 Partial Approval THOMAS LOGRASSO
Interior/Exterior Lathing 12/13/2022 Partial Approval THOMAS LOGRASSO
Shower Pan 12/13/2022 Approved THOMAS LOGRASSO
ELECTRICAL-Final 5/2/2023 Corrections Issued THOMAS LOGRASSO
HVAC-Final 5/2/2023 Approved THOMAS LOGRASSO
PLUMBING-Final 5/2/2023 Approved THOMAS LOGRASSO
SGSOV-Seismic Gas S/O Valve 5/2/2023 SGSOV Approved THOMAS LOGRASSO
Smoke Detectors 5/2/2023 Approved THOMAS LOGRASSO
BUILDING-Rough-Frame 5/31/2023 Approved THOMAS LOGRASSO
Final 5/31/2023 Corrections Issued THOMAS LOGRASSO
Green Building Final 5/31/2023 Not Ready for Inspection THOMAS LOGRASSO
Green Building Rough 5/31/2023 Approved THOMAS LOGRASSO
Final 7/13/2023 OK to Issue CofO THOMAS LOGRASSO
Green Building Final 7/13/2023 Approved THOMAS LOGRASSO