14924 W CAMAROSA DR 90272
Certificate Information: 14924 W CAMAROSA DR 90272
- Application / Permit
- 20014-10000-01191
- Plan Check / Job No.
- B20LA05169
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (7) Garage - Private
- Work Description
- REMODEL AND 536SQ.FT ADDITION TO (E) 2 STORY S.F.D
- Permit Issued
- Issued on 9/8/2020
- Issuing Office
- Current Status
- CofO Issued on 9/21/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/13/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 3/20/2020 | RACHEL BEYENE |
| Corrections Issued | 3/25/2020 | RACHEL BEYENE |
| Quality Review Completed | 4/2/2020 | STANLEY RAAP |
| Applicant returned to address corrections | 5/29/2020 | RACHEL BEYENE |
| Applicant returned to address corrections | 6/5/2020 | RACHEL BEYENE |
| Applicant returned to address corrections | 6/17/2020 | RACHEL BEYENE |
| Applicant returned to address corrections | 6/26/2020 | RACHEL BEYENE |
| Green Plans Picked Up | 7/21/2020 | APPLICANT |
| Applicant returned to address corrections | 8/19/2020 | RACHEL BEYENE |
| Plan Check Approved | 9/4/2020 | RAHEL BEYENE |
| Issued | 9/8/2020 | APPLICANT |
| Building Plans Picked Up | 9/9/2020 | APPLICANT |
| CofO in Progress | 9/11/2023 | EVAN COOPER |
| Permit Finaled | 9/21/2023 | DANIEL ORRANTE |
| CofO Issued | 9/21/2023 | DANIEL ORRANTE |
| Permit Finaled | 9/21/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 5/8/2020 | DINAH GARIN |
| Sewer availability | Cleared | 5/8/2020 | DINAH GARIN |
| City Hist. Cultural Monument | Cleared | 5/15/2020 | LAMBERT GIESSINGER |
| HPOZ | Cleared | 5/15/2020 | LAMBERT GIESSINGER |
| Hist. Property Cntrct Mgr Appr | Cleared | 5/15/2020 | LAMBERT GIESSINGER |
| Grading Pre-Inspection | Cleared | 5/29/2020 | VASIL MIHALEV |
| Disturb/Remove Protected Trees | Cleared | 6/17/2020 | STEPHEN DUPREY |
| Green Code | Cleared | 7/21/2020 | KHEDER ALRAZAA |
| Low Impact Development | Cleared | 8/6/2020 | MITESH PATEL |
| GPI Written Notices | Cleared | 8/19/2020 | RAHEL BEYENE |
| Roof/Waste drainage to street | Cleared | 8/26/2020 | DINAH GARIN |
Contact Information
| Architect | Rios,, Mark William; Lic. No.: C15744 | 3101 W EXPOSITION PLACE LOS ANGELES, CA 90018 |
| Contractor | G H B W; Lic. No.: 983577-B | 3209 LA CIENAGA AVE LOS ANGELES, CA 90034 |
| Engineer | Uhles,, Scott Delane; Lic. No.: C72391 | 2909 ARIZONA AVE 5 SANTA MONICA, CA 90404 |
| Engineer | Varela, Olivas, Benjamin; Lic. No.: S5714 | 12831 PANAMA STREET LOS ANGELES, CA 90066 |
Inspector Information
| STEPHANIE SWANSON, (213) 469-1255 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 11/9/2020 | Partial Approval | ANDREW NAVE |
| PLUMBING-Rough | 12/18/2020 | Partial Approval | MICHAEL PELHAM |
| Footing/Foundation/Slab | 1/21/2021 | Partial Approval | ANDREW NAVE |
| Deputy Drilled-In Anchors | 4/5/2021 | Conditional Approval | ANDREW NAVE |
| Wood Frame | 6/23/2021 | Corrections Issued | ANDREW NAVE |
| Floor/Roof Diaphrgm/Shear Wall | 6/29/2021 | Partial Approval | ANDREW NAVE |
| PLUMBING-Rough | 7/9/2021 | Conditional Approval | ANDREW NAVE |
| Floor/Roof Diaphrgm/Shear Wall | 7/16/2021 | Partial Approval | ANDREW NAVE |
| Reinforced Concrete Frame | 8/2/2021 | Corrections Issued | ANDREW NAVE |
| ELECTRICAL-Rough | 8/19/2021 | Partial Approval | JESUS RODRIGUEZ |
| Underground Mechanical | 8/19/2021 | Partial Approval | JESUS RODRIGUEZ |
| PLUMBING-Rough | 8/24/2021 | Partial Approval | ANDREW NAVE |
| Sewer | 8/31/2021 | Approved | ANDREW NAVE |
| HVAC-Rough | 9/13/2021 | Not Ready for Inspection | JAVIER RAMOS JR |
| HVAC-Rough | 9/16/2021 | Corrections Issued | ANDREW NAVE |
| BUILDING-Rough-Frame | 9/17/2021 | Partial Inspection | ANDREW NAVE |
| Gas Test | 9/17/2021 | Approved | ANDREW NAVE |
| Green Building Rough | 9/17/2021 | Not Ready for Inspection | ANDREW NAVE |
| Sewer | 9/20/2021 | Approved | ANDREW NAVE |
| ELECTRICAL-Rough | 10/6/2021 | Partial Approval | ANDREW NAVE |
| HVAC-Rough | 10/6/2021 | Partial Approval | ANDREW NAVE |
| BUILDING-Rough-Frame | 10/15/2021 | Partial Approval | ANDREW NAVE |
| Green Building Rough | 10/15/2021 | Not Ready for Inspection | ANDREW NAVE |
| HVAC-Rough | 10/15/2021 | Approved | ANDREW NAVE |
| Wood Frame | 10/15/2021 | Partial Inspection | ANDREW NAVE |
| Interior/Exterior Lathing | 10/26/2021 | Corrections Issued | STEPHANIE SWANSON |
| Green Building Rough | 10/28/2021 | Approved | ANDREW NAVE |
| Interior/Exterior Lathing | 10/28/2021 | Partial Inspection | ANDREW NAVE |
| Shower Pan | 10/28/2021 | Corrections Issued | ANDREW NAVE |
| BUILDING-Rough-Frame | 11/12/2021 | Not Ready for Inspection | RYAN SALAZAR |
| Insulation | 11/12/2021 | Not Ready for Inspection | RYAN SALAZAR |
| BUILDING-Rough-Frame | 11/16/2021 | Approved | ANDREW NAVE |
| Insulation | 11/16/2021 | Partial Approval | ANDREW NAVE |
| Interior/Exterior Lathing | 11/16/2021 | Corrections Issued | ANDREW NAVE |
| Insulation | 11/18/2021 | Approved | RYAN SALAZAR |
| Drywall Nailing | 11/24/2021 | Approved | KRISTEN CAUSEY |
| Interior/Exterior Lathing | 12/7/2021 | Partial Approval | ANDREW NAVE |
| Shower Pan | 12/7/2021 | Not Ready for Inspection | ANDREW NAVE |
| Interior/Exterior Lathing | 12/22/2021 | Conditional Approval | STEPHANIE SWANSON |
| Shower Pan | 12/22/2021 | Corrections Issued | STEPHANIE SWANSON |
| Shower Pan | 12/28/2021 | Partial Approval | ANDREW NAVE |
| Shower Pan | 3/17/2022 | Partial Approval | JOHN KIDWELL |
| Interior/Exterior Lathing | 3/30/2022 | Partial Approval | JUAN VALENZUELA |
| Shower Pan | 3/30/2022 | Approved | JUAN VALENZUELA |
| Interior/Exterior Lathing | 4/19/2022 | Not Ready for Inspection | ANDREW NAVE |
| Interior/Exterior Lathing | 4/25/2022 | Partial Approval | ANDREW NAVE |
| Interior/Exterior Lathing | 4/27/2022 | Partial Approval | ANDREW NAVE |
| Service/Power Release | 5/3/2022 | Approved | ANDREW NAVE |
| Interior/Exterior Lathing | 5/13/2022 | Partial Approval | JOHN KIDWELL |
| ELECTRICAL-Rough | 5/27/2022 | Corrections Issued | ANDREW NAVE |
| Gas Test | 6/9/2022 | Approved | ANDREW NAVE |
| HVAC-Final | 6/14/2022 | Corrections Issued | ANDREW NAVE |
| ELECTRICAL-Final | 6/15/2022 | Corrections Issued | ANDREW NAVE |
| HVAC-Final | 6/15/2022 | Approved | ANDREW NAVE |
| ELECTRICAL-Final | 6/17/2022 | Approved | JUAN VALENZUELA |
| PLUMBING-Final | 6/17/2022 | Approved | JUAN VALENZUELA |
| Final | 6/21/2022 | Corrections Issued | ANDREW NAVE |
| Footing/Foundation/Slab | 6/21/2022 | Approved | ANDREW NAVE |
| Green Building Final | 6/21/2022 | Corrections Issued | ANDREW NAVE |
| SGSOV-Seismic Gas S/O Valve | 6/21/2022 | SGSOV Approved | ANDREW NAVE |
| Smoke Detectors | 6/21/2022 | Approved | ANDREW NAVE |
| Final | 6/27/2022 | Corrections Issued | ANDREW NAVE |
| Green Building Final | 6/27/2022 | Approved | ANDREW NAVE |
| Final | 3/31/2023 | Conditional Approval | KENNETH NAGLE |
| Final | 9/11/2023 | OK to Issue CofO | EVAN COOPER |