2322 N GLOVER PL 90031
Certificate Information: 2322 N GLOVER PL 90031
- Application / Permit
- 20010-30000-04821
- Plan Check / Job No.
- B20WL05445
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- construction of (n) two-story s.f.r. of type V construction with attached garage
- Permit Issued
- Issued on 6/7/2021
- Issuing Office
- Current Status
- CofO Issued on 2/1/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/15/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 12/23/2020 | KAMRAN GHOTBI RAVANDI |
| Corrections Issued | 12/28/2020 | KAMRAN GHOTBI RAVANDI |
| Quality Review Completed | 12/29/2020 | CHIHARU SUZUKI |
| Building Plans Picked Up | 1/4/2021 | APPLICANT |
| Applicant returned to address corrections | 4/27/2021 | KAMRAN GHOTBI RAVANDI |
| Applicant returned to address corrections | 5/4/2021 | KAMRAN GHOTBI RAVANDI |
| Plan Check Approved | 5/15/2021 | KAMRAN GHOTBI RAVANDI |
| Issued | 6/7/2021 | APPLICANT |
| CofO in Progress | 1/20/2022 | THOMAS LOGRASSO |
| CofO Issued | 2/1/2022 | DEROLD HAUFF |
| Permit Finaled | 2/1/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Permit | Cleared | 1/7/2021 | DINAH GARIN |
| Eng Process Fee Ord 176,300 | Cleared | 1/20/2021 | CECILIO NAVARRO |
| Trees in Parkway | Cleared | 2/8/2021 | JOHN KIM |
| Hydrant and Access approval | Cleared | 2/16/2021 | MATTHEW CRAIG |
| ZI | Cleared | 2/19/2021 | LOUIS ORTEGA |
| Sewer availability | Cleared | 3/18/2021 | CECILIO NAVARRO |
| Low Impact Development | Cleared | 4/19/2021 | IDA MEISAMI-FARD |
| Roof/Waste drainage to street | Cleared | 4/20/2021 | THAN WIN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Lee,, Sang Youck; Lic. No.: S3821 | 3531 BROOKHILL ST GLENDALE, CA 91214 |
Inspector Information
| HAMIK HARTOUNIAN, (213) 202-3275 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 6/14/2021 | Partial Approval | OSVALDO PARAMO |
| PLUMBING-Rough | 6/14/2021 | Partial Approval | OSVALDO PARAMO |
| Excavation/Setback/Form/Re-Bar | 6/17/2021 | Approved | CRAIG VAUGHAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/8/2021 | Corrections Issued | SCOTT FINNILA |
| Floor/Roof Diaphrgm/Shear Wall | 7/9/2021 | Partial Approval | SCOTT FINNILA |
| BUILDING-Rough-Frame | 9/1/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| ELECTRICAL-Rough | 9/1/2021 | Approved | KATHRYN BUTTERWORTH |
| Green Building Rough | 9/1/2021 | Not Ready for Inspection | KATHRYN BUTTERWORTH |
| HVAC-Rough | 9/1/2021 | Corrections Issued | KATHRYN BUTTERWORTH |
| MERV13>=Rough | 9/1/2021 | Approved | KATHRYN BUTTERWORTH |
| PLUMBING-Rough | 9/1/2021 | Corrections Issued | KATHRYN BUTTERWORTH |
| Sewer | 9/1/2021 | Corrections Issued | KATHRYN BUTTERWORTH |
| Verify Sprinkler Sign Off | 9/1/2021 | Corrections Issued | KATHRYN BUTTERWORTH |
| BUILDING-Rough-Frame | 9/8/2021 | Corrections Issued | THOMAS LOGRASSO |
| Green Building Rough | 9/8/2021 | Approved | THOMAS LOGRASSO |
| Verify Sprinkler Sign Off | 9/8/2021 | Not Ready for Inspection | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 9/15/2021 | Partial Approval | THOMAS LOGRASSO |
| HVAC-Rough | 9/15/2021 | Approved | THOMAS LOGRASSO |
| PLUMBING-Rough | 9/15/2021 | Approved | THOMAS LOGRASSO |
| Underground Mechanical | 9/15/2021 | Partial Approval | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 9/30/2021 | Corrections Issued | THOMAS LOGRASSO |
| Verify Sprinkler Sign Off | 9/30/2021 | Approved | THOMAS LOGRASSO |
| Insulation | 10/5/2021 | Conditional Approval | THOMAS LOGRASSO |
| Drywall Nailing | 10/7/2021 | Conditional Approval | THOMAS LOGRASSO |
| Interior/Exterior Lathing | 10/7/2021 | Partial Approval | THOMAS LOGRASSO |
| Interior/Exterior Lathing | 10/14/2021 | Approved | THOMAS LOGRASSO |
| Shower Pan | 10/14/2021 | Approved | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 12/16/2021 | Approved | THOMAS LOGRASSO |
| Drywall Nailing | 12/16/2021 | Approved | THOMAS LOGRASSO |
| ELECTRICAL-Final | 12/16/2021 | Corrections Issued | THOMAS LOGRASSO |
| Final | 12/16/2021 | Corrections Issued | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 12/16/2021 | Approved | THOMAS LOGRASSO |
| Gas Test | 12/16/2021 | Approved | THOMAS LOGRASSO |
| Green Building Final | 12/16/2021 | Not Ready for Inspection | THOMAS LOGRASSO |
| HVAC-Final | 12/16/2021 | Corrections Issued | THOMAS LOGRASSO |
| MERV13>=Final | 12/16/2021 | Not Ready for Inspection | THOMAS LOGRASSO |
| PLUMBING-Final | 12/16/2021 | Corrections Issued | THOMAS LOGRASSO |
| SGSOV-Seismic Gas S/O Valve | 12/16/2021 | SGSOV Approved | THOMAS LOGRASSO |
| Service/Power Release | 12/16/2021 | Not Ready for Inspection | THOMAS LOGRASSO |
| Smoke Detectors | 12/16/2021 | Approved | THOMAS LOGRASSO |
| ELECTRICAL-Final | 12/22/2021 | Approved | THOMAS LOGRASSO |
| Final | 12/22/2021 | Corrections Issued | THOMAS LOGRASSO |
| Green Building Final | 12/22/2021 | Approved | THOMAS LOGRASSO |
| HVAC-Final | 12/22/2021 | Approved | THOMAS LOGRASSO |
| MERV13>=Final | 12/22/2021 | Approved | THOMAS LOGRASSO |
| PLUMBING-Final | 12/22/2021 | Approved | THOMAS LOGRASSO |
| Service/Power Release | 12/22/2021 | Not Ready for Inspection | THOMAS LOGRASSO |
| Final | 1/20/2022 | OK to Issue CofO | THOMAS LOGRASSO |
| Service/Power Release | 1/20/2022 | Approved | THOMAS LOGRASSO |