654 N ALMA REAL DR 90272
Certificate Information: 654 N ALMA REAL DR 90272
- Application / Permit
- 20010-30000-01409
- Plan Check / Job No.
- B20WL01858
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (7) Garage - Private
- Work Description
- (N) 2 CAR GARAGE FIRST FLOOR & SECOND FLOOR ACCESSORY LIVING QUARTERS
- Permit Issued
- Issued on 7/19/2021
- Issuing Office
- Current Status
- Issued on 7/19/2021
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 6/19/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/8/2020 | TARIK SAOUD |
| Corrections Issued | 7/11/2020 | TARIK SAOUD |
| Quality Review Completed | 7/16/2020 | KAMRAN GHOTBI RAVANDI |
| Applicant returned to address corrections | 11/9/2020 | TARIK SAOUD |
| Building Plans Picked Up | 11/9/2020 | APPLICANT |
| Plan Check Approved | 4/28/2021 | TARIK SAOUD |
| Issued | 7/19/2021 | APPLICANT |
Permit Application Clearance Information
| Low Impact Development | Cleared | 12/22/2020 | JORGE MEJIA LEMUS |
| Coastal Zone | Cleared | 1/22/2021 | DENZEL HENDERSON |
| Eng Process Fee Ord 176,300 | Cleared | 3/16/2021 | HISASHI KOBAYAKAWA |
| Permit | Cleared | 3/16/2021 | HISASHI KOBAYAKAWA |
| Roof/Waste drainage to street | Cleared | 3/16/2021 | HISASHI KOBAYAKAWA |
| Sewer availability | Cleared | 3/16/2021 | HISASHI KOBAYAKAWA |
| Grading Pre-Inspection | Cleared | 4/28/2021 | TARIK SAOUD |
Contact Information
| Architect | Blumenberg,, Richard Leo; Lic. No.: C10862 | 15200 SUNSET BLVD STE 201 PACIFIC PALISADES, CA 90272 |
| Contractor | Azure Construction Inc; Lic. No.: 1058246-B | 3877 GRAND VIEW BLVD STE 200 LOS ANGELES, CA 90066 |
| Engineer | Niver,, Kenneth Earl; Lic. No.: S2554 | 10845 LINDBROOK DR STE 203 W LOS ANGELES, CA 90024 |
Inspector Information
| STEPHANIE SWANSON, (213) 469-1255 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/4/2021 | Approved | ANDREW NAVE |
| Pre-Inspection | 8/16/2021 | Approved | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 8/24/2021 | Partial Inspection | ANDREW NAVE |
| Pre-Inspection | 9/3/2021 | Partial Inspection | KENNETH NAGLE |
| Excavation/Setback/Form/Re-Bar | 9/14/2021 | Partial Approval | ANDREW NAVE |
| Underground Mechanical | 9/14/2021 | Approved | ANDREW NAVE |
| Footing/Foundation/Slab | 9/21/2021 | No Access for Inspection | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 9/22/2021 | Partial Approval | ANDREW NAVE |
| Footing/Foundation/Slab | 10/5/2021 | Partial Approval | ANDREW NAVE |
| Underground Mechanical | 10/25/2021 | Approved | ANDREW NAVE |
| Underground Mechanical | 10/26/2021 | Approved | ANDREW NAVE |
| Floor/Roof Diaphrgm/Shear Wall | 11/2/2021 | Partial Approval | ANDREW NAVE |
| Floor/Roof Diaphrgm/Shear Wall | 12/6/2021 | Partial Approval | ANDREW NAVE |
| PLUMBING-Rough | 1/5/2022 | Approved | ANDREW NAVE |
| Footing/Foundation/Slab | 1/10/2022 | Partial Approval | ANDREW NAVE |
| Footing/Foundation/Slab | 1/18/2022 | Approved | ANDREW NAVE |
| Wood Frame | 1/25/2022 | Corrections Issued | ANDREW NAVE |
| Floor/Roof Diaphrgm/Shear Wall | 2/23/2022 | Approved | ANDREW NAVE |
| ELECTRICAL-Rough | 3/22/2022 | Approved | ANDREW NAVE |
| HVAC-Rough | 3/22/2022 | Partial Approval | ANDREW NAVE |
| BUILDING-Rough-Frame | 3/24/2022 | Approved | JUAN VALENZUELA |
| Green Building Rough | 3/24/2022 | Approved | JUAN VALENZUELA |
| HVAC-Rough | 3/24/2022 | Approved | JUAN VALENZUELA |
| PLUMBING-Rough | 3/24/2022 | Conditional Approval | JUAN VALENZUELA |
| Verify Sprinkler Sign Off | 3/24/2022 | Approved | JUAN VALENZUELA |
| Interior/Exterior Lathing | 3/25/2022 | Partial Approval | ANDREW NAVE |
| Interior/Exterior Lathing | 3/30/2022 | Partial Approval | JUAN VALENZUELA |
| Insulation | 5/24/2022 | Approved | JOHN KIDWELL |
| Drywall Nailing | 6/9/2022 | Approved | ANDREW NAVE |
| Interior/Exterior Lathing | 7/15/2022 | Approved | ANDREW NAVE |
| ELECTRICAL-Final | 9/6/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| ELECTRICAL-Final | 9/29/2022 | Corrections Issued | BRENDAN LOONEY |
| HVAC-Final | 9/29/2022 | Corrections Issued | BRENDAN LOONEY |
| PLUMBING-Final | 9/29/2022 | Corrections Issued | BRENDAN LOONEY |
| SGSOV-Seismic Gas S/O Valve | 9/29/2022 | SGSOV Approved | BRENDAN LOONEY |
| ELECTRICAL-Final | 10/5/2022 | Not Ready for Inspection | BRENDAN LOONEY |
| HVAC-Final | 10/5/2022 | Not Ready for Inspection | BRENDAN LOONEY |
| PLUMBING-Final | 10/5/2022 | Approved | BRENDAN LOONEY |
| ELECTRICAL-Final | 10/17/2022 | Corrections Issued | BRENDAN LOONEY |
| HVAC-Final | 10/17/2022 | Approved | BRENDAN LOONEY |
| ELECTRICAL-Final | 7/19/2023 | Approved | GERMAN RODRIGUEZ MENDOZA |
| Final | 5/2/2024 | Corrections Issued | EVAN COOPER |
| Green Building Final | 5/2/2024 | No Access for Inspection | EVAN COOPER |
| Service/Power Release | 5/2/2024 | No Access for Inspection | EVAN COOPER |
| Smoke Detectors | 5/2/2024 | No Access for Inspection | EVAN COOPER |
| Final | 5/8/2024 | Corrections Issued | EVAN COOPER |
| Green Building Final | 5/8/2024 | Approved | EVAN COOPER |
| Service/Power Release | 5/8/2024 | Approved | EVAN COOPER |
| Smoke Detectors | 5/8/2024 | Approved | EVAN COOPER |