611 N CURSON AVE 90036
Certificate Information: 611 N CURSON AVE 90036
- Application / Permit
- 20010-30000-00219
- Plan Check / Job No.
- B20WL00311
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- (n) 2-story s.f.r. w/ attached 2-car garage
- Permit Issued
- Issued on 6/12/2020
- Issuing Office
- Current Status
- CofO Issued on 3/20/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/22/2020 | APPLICANT |
| Green Plans Picked Up | 2/6/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 2/20/2020 | REZA HAGHIGHAT |
| Corrections Issued | 2/24/2020 | REZA HAGHIGHAT |
| Quality Review Completed | 3/6/2020 | KAMRAN GHOTBI RAVANDI |
| Plan Check Approved | 6/12/2020 | REZA HAGHIGHAT |
| Issued | 6/12/2020 | APPLICANT |
| Building Plans Picked Up | 6/15/2020 | APPLICANT |
| CofO in Progress | 3/12/2021 | CHRIS CHRISTENSEN |
| Permit Finaled | 3/20/2021 | DEROLD HAUFF |
| CofO Issued | 3/20/2021 | DEROLD HAUFF |
| Permit Finaled | 3/20/2021 | DEROLD HAUFF |
Permit Application Clearance Information
| Green Code | Cleared | 4/8/2020 | RICHARD GARCIA |
| Trees in Parkway | Cleared | 4/13/2020 | JOHN KIM |
| Hydrant and Access approval | Cleared | 4/23/2020 | GILBERT URREA |
| Low Impact Development | Cleared | 5/8/2020 | ORVAL HERNANDEZ-MARCI |
| Eng Process Fee Ord 176,300 | Cleared | 5/29/2020 | CECILIO NAVARRO |
| Permit | Cleared | 5/29/2020 | CECILIO NAVARRO |
| Roof/Waste drainage to street | Cleared | 6/1/2020 | CECILIO NAVARRO |
| Sewer availability | Cleared | 6/1/2020 | CECILIO NAVARRO |
Contact Information
| Architect | Niemerski,, Kenneth Chester; Lic. No.: C23971 | 52 DAWNWOOD LADERA RANCH, CA 92694 |
| Contractor | T J C Home Builders Llc; Lic. No.: 1025507-B | 26880 ALISO VIEJO PKWY STE 100 ALISO VIEJO, CA 92656 |
| Engineer | De, Leon, Cynthia Aguilar; Lic. No.: C31604 | 8061 SAN MATEO CIR BUENA PARK, CA 90620 |
| Engineer | Nguyen,, Huan Ngoc; Lic. No.: C64238 | 13831 TYPEE WAY IRVINE, CA 92620 |
| Engineer | Toedter,, Randy W; Lic. No.: S2991 | 7474 EISENHOWER ST VENTURA, CA 93003 |
Inspector Information
| JOSE MACIAS, (213) 202-3125 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Sewer | 6/29/2020 | Approved | CHRIS CHRISTENSEN |
| Underground Mechanical | 6/29/2020 | Approved | CHRIS CHRISTENSEN |
| METHANE-Subgrade | 7/16/2020 | Approved | CHRIS CHRISTENSEN |
| METHANE-Barrier | 7/28/2020 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| METHANE-Barrier | 7/31/2020 | Approved | CHRIS CHRISTENSEN |
| Footing/Foundation/Slab | 8/10/2020 | Approved | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 8/28/2020 | Partial Approval | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 9/18/2020 | Partial Approval | CHRIS CHRISTENSEN |
| Deputy Wood Construction | 9/21/2020 | No Access for Inspection | ELMER BLAND |
| ELECTRICAL-Rough | 10/5/2020 | Corrections Issued | CHRIS CHRISTENSEN |
| HVAC-Rough | 10/5/2020 | Approved | CHRIS CHRISTENSEN |
| ELECTRICAL-Rough | 10/7/2020 | Approved | CHRIS CHRISTENSEN |
| METHANE-Final | 10/7/2020 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Rough | 10/7/2020 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Rough | 10/13/2020 | Corrections Issued | CHRIS CHRISTENSEN |
| Shower Pan | 10/14/2020 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 10/23/2020 | Partial Approval | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 10/29/2020 | Approved | CHRIS CHRISTENSEN |
| Green Building Rough | 10/29/2020 | Approved | CHRIS CHRISTENSEN |
| Verify Sprinkler Sign Off | 10/29/2020 | Approved | CHRIS CHRISTENSEN |
| Insulation | 11/2/2020 | Approved | CHRIS CHRISTENSEN |
| Drywall Nailing | 11/10/2020 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 11/16/2020 | Partial Approval | CHRIS CHRISTENSEN |
| Pre-Inspection | 12/22/2020 | Approved | CHRIS CHRISTENSEN |
| ELECTRICAL-Final | 1/22/2021 | Approved | CHRIS CHRISTENSEN |
| Gas Test | 1/29/2021 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Final | 1/29/2021 | Approved | CHRIS CHRISTENSEN |
| HVAC-Final | 2/2/2021 | Approved | CHRIS CHRISTENSEN |
| Final | 3/8/2021 | Corrections Issued | CHRIS CHRISTENSEN |
| Green Building Final | 3/8/2021 | Corrections Issued | CHRIS CHRISTENSEN |
| SGSOV-Seismic Gas S/O Valve | 3/8/2021 | SGSOV Approved | CHRIS CHRISTENSEN |
| Service/Power Release | 3/8/2021 | Approved | CHRIS CHRISTENSEN |
| Smoke Detectors | 3/8/2021 | Approved | CHRIS CHRISTENSEN |
| Final | 3/12/2021 | OK to Issue CofO | CHRIS CHRISTENSEN |
| Green Building Final | 3/12/2021 | Approved | CHRIS CHRISTENSEN |