18222 W CHATSWORTH ST 91326
Certificate Information: 18222 W CHATSWORTH ST 91326
- Application / Permit
- 20010-20000-04541
- Plan Check / Job No.
- B20VN15365
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW 20' x 30' DET. TWO-STORY ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d)
- Permit Issued
- Issued on 4/3/2024
- Issuing Office
- Valley
- Current Status
- CofO Issued on 8/18/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/29/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 12/23/2020 | SEAN SHAHMIRI |
| Corrections Issued | 12/30/2020 | SEAN SHAHMIRI |
| Quality Review Completed | 1/15/2021 | OMID HEDAYAT |
| Building Plans Picked Up | 1/21/2021 | APPLICANT |
| Plan Check Approved | 9/21/2021 | SEAN SHAHMIRI |
| Plan Check Approved | 3/26/2024 | SEAN SHAHMIRI |
| Issued | 4/3/2024 | APPLICANT |
| CofO in Progress | 8/12/2025 | DAVID SCANTLIN |
| Permit Finaled | 8/18/2025 | JOHN JANSON |
| CofO Issued | 8/18/2025 | JOHN JANSON |
| Permit Finaled | 8/18/2025 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 2/25/2021 | ADRIAN CASTRO |
| Eng Process Fee Ord 176,300 | Cleared | 2/25/2021 | ADRIAN CASTRO |
| Sewer availability | Cleared | 2/25/2021 | ADRIAN CASTRO |
| Hydrant and Access approval | Cleared | 4/26/2021 | JOHN CONNEALLY |
| Low Impact Development | Cleared | 6/29/2021 | ORVAL HERNANDEZ-MARCI |
| Roof/Waste drainage to street | Cleared | 6/30/2021 | CARLOS AGUILERA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Adzhemyan,, Arsen; Lic. No.: C89103 | 1010 RALEIGH ST APT 107 GLENDALE, CA 91205 |
Inspector Information
| JACK KARGODORIAN, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
| KRISTEN CAUSEY, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 7/16/2024 | Approved | DAVID SCANTLIN |
| Footing/Foundation/Slab | 7/23/2024 | Approved | DAVID SCANTLIN |
| Floor/Roof Diaphrgm/Shear Wall | 8/7/2024 | Partial Approval | KRISTEN CAUSEY |
| Pre-Inspection | 8/21/2024 | Partial Inspection | KRISTEN CAUSEY |
| HVAC-Rough | 8/26/2024 | Approved | KRISTEN CAUSEY |
| ELECTRICAL-Rough | 9/10/2024 | Approved | DAVID SCANTLIN |
| Special/Order Compliance | 9/10/2024 | Approved | SCOTT SOBEL |
| BUILDING-Rough-Frame | 9/16/2024 | Approved | DAVID SCANTLIN |
| Green Building Rough | 9/16/2024 | Not Ready for Inspection | DAVID SCANTLIN |
| PLUMBING-Rough | 9/16/2024 | Approved | DAVID SCANTLIN |
| Verify Sprinkler Sign Off | 9/16/2024 | Approved | DAVID SCANTLIN |
| Green Building Rough | 9/27/2024 | Approved | DAVID SCANTLIN |
| Insulation | 9/27/2024 | Approved | DAVID SCANTLIN |
| Interior/Exterior Lathing | 9/27/2024 | Partial Approval | DAVID SCANTLIN |
| Drywall Nailing | 10/4/2024 | Approved | KRISTEN CAUSEY |
| Interior/Exterior Lathing | 10/7/2024 | Partial Approval | KRISTEN CAUSEY |
| Shower Pan | 10/23/2024 | Approved | DAVID SCANTLIN |
| Sewer | 11/13/2024 | Approved | DAVID SCANTLIN |
| Interior/Exterior Lathing | 12/16/2024 | Approved | DAVID SCANTLIN |
| Underground Mechanical | 1/17/2025 | Approved | DAVID SCANTLIN |
| Underground Mechanical | 4/7/2025 | Approved | DAVID SCANTLIN |
| SGSOV-Seismic Gas S/O Valve | 7/21/2025 | SGSOV Not Ready | DAVID SCANTLIN |
| Final | 7/23/2025 | Corrections Issued | DAVID SCANTLIN |
| Green Building Final | 7/23/2025 | Approved | DAVID SCANTLIN |
| SGSOV-Seismic Gas S/O Valve | 7/23/2025 | SGSOV Approved | DAVID SCANTLIN |
| Smoke Detectors | 7/23/2025 | Approved | DAVID SCANTLIN |
| Final | 8/11/2025 | Corrections Issued | DAVID SCANTLIN |
| Service/Power Release | 8/11/2025 | Approved | DAVID SCANTLIN |
| Final | 8/13/2025 | OK to Issue CofO | DAVID SCANTLIN |
| Service/Power Release | 8/13/2025 | Approved | DAVID SCANTLIN |