20811 1/2 W TIARA ST 91367
Certificate Information: 20811 1/2 W TIARA ST 91367
- Application / Permit
- 20010-20000-03855
- Plan Check / Job No.
- B20VN13690
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- (N) 28' X 25' TWO STORY ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d), ALL WORK PER ENGINEERING
- Permit Issued
- Issued on 9/29/2021
- Issuing Office
- Valley
- Current Status
- CofO Issued on 3/14/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/20/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 11/12/2020 | SEWADA ZADOORIAN MILAGARDI |
| Corrections Issued | 11/18/2020 | SEWADA ZADOORIAN MILAGARDI |
| Quality Review Completed | 12/7/2020 | OMID HEDAYAT |
| Building Plans Picked Up | 12/8/2020 | APPLICANT |
| Applicant returned to address corrections | 4/29/2021 | SEWADA ZADOORIAN MILAGARDI |
| Applicant returned to address corrections | 9/13/2021 | SEWADA ZADOORIAN MILAGARDI |
| Plan Check Approved | 9/23/2021 | SEWADA ZADOORAN MILAGARDI |
| Issued | 9/29/2021 | APPLICANT |
| CofO in Progress | 3/10/2022 | STEVEN BACK |
| Permit Finaled | 3/14/2022 | JOHN JANSON |
| CofO Issued | 3/14/2022 | JOHN JANSON |
| Permit Finaled | 3/14/2022 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 1/7/2021 | CECILIO NAVARRO |
| Eng Process Fee Ord 176,300 | Cleared | 1/7/2021 | CECILIO NAVARRO |
| Sewer availability | Cleared | 1/7/2021 | CECILIO NAVARRO |
| Hydrant and Access approval | Cleared | 2/24/2021 | JEREMY CARTER |
| Miscellaneous | Cleared | 3/19/2021 | LAUREN PADICK |
| Low Impact Development | Cleared | 4/12/2021 | IDA MEISAMI-FARD |
| Roof/Waste drainage to street | Cleared | 4/12/2021 | ABDULLAH SADOZAI |
| GPI Written Notices | Cleared | 9/23/2021 | SEWADA ZADOORAN MILAGARDI |
| Grading Pre-Inspection | Cleared | 9/23/2021 | SEWADA ZADOORAN MILAGARDI |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Aronianpour,, Eilan; Lic. No.: C88101 | 7242 JELLICO AVE LAKE BALBOA, CA 91406 |
| Engineer | Salehipour,, Sassan A; Lic. No.: GE2579 | 1290 N LAKE AVENUE #204 PASADENA, CA 91104 |
| Engineer | Yadegari,, Shahriar; Lic. No.: C64591 | 321 S SAN VICENTE BLVD #601 LOS ANGELES, CA 90048 |
Inspector Information
| ALEXANDER HANDY, (818) 774-4317 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 10/19/2021 | Partial Approval | STEVEN BACK |
| Piling/Pier/Caisson | 10/19/2021 | Partial Approval | STEVEN BACK |
| Deputy Reinf. Concrete | 10/20/2021 | Approved | RONALD COWAN |
| Excavation/Setback/Form/Re-Bar | 11/2/2021 | Partial Approval | STEVEN BACK |
| Footing/Foundation/Slab | 11/2/2021 | Partial Approval | STEVEN BACK |
| PLUMBING-Rough | 11/2/2021 | Partial Approval | STEVEN BACK |
| Underground Mechanical | 11/3/2021 | Partial Approval | STEVEN BACK |
| Deputy Reinf. Concrete | 11/4/2021 | Conditional Approval | HENRY KIM |
| Footing/Foundation/Slab | 11/9/2021 | Partial Approval | STEVEN BACK |
| Excavation/Setback/Form/Re-Bar | 11/15/2021 | Approved | STEVEN BACK |
| Footing/Foundation/Slab | 11/15/2021 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 11/29/2021 | Not Ready for Inspection | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 11/29/2021 | Partial Inspection | STEVEN BACK |
| Green Building Rough | 11/29/2021 | Not Ready for Inspection | STEVEN BACK |
| Verify Sprinkler Sign Off | 11/29/2021 | Not Ready for Inspection | STEVEN BACK |
| ELECTRICAL-Rough | 12/7/2021 | Not Ready for Inspection | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 12/7/2021 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Rough | 12/16/2021 | Approved | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 12/16/2021 | Approved | STEVEN BACK |
| PLUMBING-Rough | 12/16/2021 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 12/22/2021 | Corrections Issued | STEVEN BACK |
| Final | 12/22/2021 | Corrections Issued | STEVEN BACK |
| Green Building Rough | 12/22/2021 | Approved | STEVEN BACK |
| HVAC-Rough | 12/22/2021 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 12/22/2021 | Partial Approval | STEVEN BACK |
| Verify Sprinkler Sign Off | 12/22/2021 | Not Ready for Inspection | STEVEN BACK |
| Insulation | 12/27/2021 | Approved | STEVEN BACK |
| Sewer | 12/27/2021 | Approved | STEVEN BACK |
| Shower Pan | 12/27/2021 | Approved | STEVEN BACK |
| Underground Mechanical | 12/27/2021 | Partial Approval | STEVEN BACK |
| Drywall Nailing | 12/30/2021 | Approved | SEAN WIRCH |
| Shower Pan | 12/30/2021 | Approved | SEAN WIRCH |
| Interior/Exterior Lathing | 1/3/2022 | Approved | SEAN WIRCH |
| Underground Mechanical | 1/3/2022 | Partial Approval | SEAN WIRCH |
| ELECTRICAL-Final | 2/10/2022 | Corrections Issued | STEVEN BACK |
| HVAC-Final | 2/10/2022 | Approved | STEVEN BACK |
| PLUMBING-Final | 2/10/2022 | Approved | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 2/10/2022 | SGSOV Approved | STEVEN BACK |
| Interior/Exterior Lathing | 2/16/2022 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 3/10/2022 | Approved | STEVEN BACK |
| Final | 3/10/2022 | OK to Issue CofO | STEVEN BACK |
| Green Building Final | 3/10/2022 | Approved | STEVEN BACK |
| Service/Power Release | 3/10/2022 | Approved | STEVEN BACK |
| Smoke Detectors | 3/10/2022 | Approved | STEVEN BACK |