20522 W DEER GRASS CT 91326

Certificate Information: 20522 W DEER GRASS CT 91326

Application / Permit
20010-20000-03415
Plan Check / Job No.
B20VN12706
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW SFD - CODE UPDATE - STD PLAN #649
Permit Issued
Issued on 4/14/2021
Issuing Office
Current Status
CofO Issued on 8/15/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/28/2020 APPLICANT
Assigned to Plan Check Engineer 10/22/2020 MARVEL DELACRUZ
Corrections Issued 10/29/2020 MARVEL DELACRUZ
Quality Review Completed 11/6/2020 STEVEN KIM
Building Plans Picked Up 11/9/2020 APPLICANT
Applicant returned to address corrections 4/9/2021 MARVEL DELACRUZ
Plan Check Approved 4/14/2021 MARVEL DELACRUZ
Issued 4/14/2021 APPLICANT
CofO in Progress 7/26/2022 SEAN WIRCH
Permit Finaled 8/15/2022 MICHAEL SMITH
CofO Issued 8/15/2022 MICHAEL SMITH
Permit Finaled 8/15/2022 MICHAEL SMITH

Permit Application Clearance Information

Low Impact Development Cleared 11/13/2020 AMMAR ELTAWIL
"T" removal Cleared 12/2/2020 DENZEL HENDERSON
Private street Cleared 12/2/2020 DENZEL HENDERSON
Specific Plan Cleared 12/2/2020 DENZEL HENDERSON
Tract Map conditions Cleared 12/2/2020 DENZEL HENDERSON
ZA Case Cleared 12/2/2020 DENZEL HENDERSON
ZA Case Cleared 12/2/2020 DENZEL HENDERSON
ZI Cleared 12/2/2020 DENZEL HENDERSON
ZI Cleared 12/2/2020 DENZEL HENDERSON
Address approval Cleared 12/3/2020 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 12/3/2020 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 12/3/2020 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 12/3/2020 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 12/3/2020 LEE GUILBEAUX
BHO/Hillside ordinance Cleared 12/3/2020 LEE GUILBEAUX
Permit Cleared 12/3/2020 LEE GUILBEAUX
Roof/Waste drainage to street Cleared 12/3/2020 LEE GUILBEAUX
Sewer availability Cleared 12/3/2020 LEE GUILBEAUX
Public Works-Highway Ded. Cleared 12/3/2020 LEE GUILBEAUX
GPI Written Notices Cleared 4/12/2021 MARVEL DELACRUZ
Grading Pre-Inspection Cleared 4/12/2021 MARVEL DELACRUZ
Green Code Cleared 4/12/2021 MARVEL DELACRUZ

Contact Information

Architect Niemerski,, Kenneth Chester; Lic. No.: C23971 52 DAWNWOOD      LADERA RANCH, CA 92694
Contractor Shapell Homes Inc; Lic. No.: 1001034-B 1140 VIRGINIA DR ATTN: TOLL   BROTHERS - TAGGERT/LEGAL    FORT WASHINGTON, PA 19034
Engineer Braatz,, Tara Elizabeth; Lic. No.: C79028 24855 CALLE CARMEL      LAGUNA HILLS, CA 92653
Engineer Hattar,, Basil Ibrahim; Lic. No.: GE2734 3525 PARK MEADOW CT      PALMDALE, CA 93551
Engineer Nelson,, William Mc Kee; Lic. No.: S3417 5 DELLWOOD      DOVE CANYON, CA 92679
Engineer Wong,, Ramon Roman; Lic. No.: S2345 1800 E. 16TH STREET      SANTA ANA, CA 92701
Geologist Berger,, Susan Michele; Lic. No.: EG2069 1559 GATEWAY DR      SIMI VALLEY, CA 93063

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 5/5/2021 Approved SEAN WIRCH
Footing/Foundation/Slab 5/24/2021 Approved SEAN WIRCH
Floor/Roof Diaphrgm/Shear Wall 6/17/2021 Partial Approval SEAN WIRCH
Floor/Roof Diaphrgm/Shear Wall 7/20/2021 Partial Approval SEAN WIRCH
Sewer 9/30/2021 Approved SEAN WIRCH
Floor/Roof Diaphrgm/Shear Wall 10/27/2021 Partial Approval SEAN WIRCH
ELECTRICAL-Rough 11/1/2021 Approved SEAN WIRCH
HVAC-Rough 11/1/2021 Corrections Issued SEAN WIRCH
PLUMBING-Rough 11/1/2021 Approved SEAN WIRCH
BUILDING-Rough-Frame 11/8/2021 Not Ready for Inspection SEAN WIRCH
Green Building Rough 11/8/2021 Not Ready for Inspection SEAN WIRCH
Verify Sprinkler Sign Off 11/8/2021 Not Ready for Inspection SEAN WIRCH
BUILDING-Rough-Frame 11/15/2021 Approved SEAN WIRCH
Green Building Rough 11/15/2021 Approved SEAN WIRCH
Verify Sprinkler Sign Off 11/15/2021 Approved SEAN WIRCH
Drywall Nailing 12/8/2021 Approved SEAN WIRCH
Interior/Exterior Lathing 12/14/2021 Not Ready for Inspection HENRY KIM
Interior/Exterior Lathing 12/17/2021 Not Ready for Inspection HENRY KIM
Interior/Exterior Lathing 1/5/2022 Partial Approval SEAN WIRCH
Interior/Exterior Lathing 2/2/2022 Approved SEAN WIRCH
Service/Power Release 3/9/2022 Approved SEAN WIRCH
Gas Test 4/26/2022 Approved SEAN WIRCH
SGSOV-Seismic Gas S/O Valve 4/26/2022 SGSOV Approved SEAN WIRCH
ELECTRICAL-Final 7/14/2022 Approved SEAN WIRCH
HVAC-Final 7/14/2022 Approved SEAN WIRCH
PLUMBING-Final 7/14/2022 Approved SEAN WIRCH
Final 7/25/2022 OK to Issue CofO SEAN WIRCH
Green Building Final 7/25/2022 Approved SEAN WIRCH
Smoke Detectors 7/25/2022 Approved SEAN WIRCH