129 S BURLINGAME AVE 90049
Certificate Information: 129 S BURLINGAME AVE 90049
- Application / Permit
- 20010-20000-03314
- Plan Check / Job No.
- B20VN12444
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW DETACHED 1-STORY ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c)¹, (d)¹, and (g) FIRE SPRINKLERES NFPA 13D
- Permit Issued
- Issued on 7/19/2021
- Issuing Office
- Current Status
- CofO Issued on 8/2/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/22/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 10/15/2020 | MOHAMMAD ESMAILI |
| Corrections Issued | 10/22/2020 | MOHAMMAD ESMAILI |
| Quality Review Completed | 11/9/2020 | OMID HEDAYAT |
| Building Plans Picked Up | 11/10/2020 | APPLICANT |
| Applicant returned to address corrections | 3/1/2021 | MOHAMMAD ESMAILI |
| Plan Check Approved | 7/19/2021 | MOHAMMAD ESMAILI |
| Issued | 7/19/2021 | APPLICANT |
| CofO in Progress | 5/26/2022 | JOHN KIDWELL |
| Permit Finaled | 8/2/2022 | DANIEL ORRANTE |
| CofO Issued | 8/2/2022 | DANIEL ORRANTE |
| Permit Finaled | 8/2/2022 | DANIEL ORRANTE |
Permit Application Clearance Information
| Specific Plan | Cleared | 11/19/2020 | NOAH MCCOY |
| ZI | Cleared | 11/19/2020 | NOAH MCCOY |
| Address approval | Cleared | 12/9/2020 | NIKTA MOUSAVI |
| Eng Process Fee Ord 176,300 | Cleared | 12/16/2020 | NIKTA MOUSAVI |
| Hydrant and Access approval | Cleared | 12/16/2020 | MATTHEW CRAIG |
| Sewer availability | Cleared | 12/18/2020 | NIKTA MOUSAVI |
| Low Impact Development | Cleared | 1/15/2021 | SARAH YOUSSEF |
| Roof/Waste drainage to street | Cleared | 1/19/2021 | NIKTA MOUSAVI |
| GPI Written Notices | Cleared | 3/8/2021 | MOHAMMAD ESMAILI |
| Grading Pre-Inspection | Cleared | 3/8/2021 | MOHAMMAD ESMAILI |
| Miscellaneous | Cleared | 7/12/2021 | JENSON LEE |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Durand,, Paul Henri; Lic. No.: S4222 | 611 N G ST OXNARD, CA 93030 |
| Engineer | Tan,, Henreik Steven; Lic. No.: C65723 | 5100 LLANO DRIVE WOODLAND HILLS, CA 91364 |
Inspector Information
| HERBERT GIRON, (310) 914-3891 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 7/30/2021 | Approved | JUAN VALENZUELA |
| Floor/Roof Diaphrgm/Shear Wall | 8/6/2021 | Conditional Approval | JOHN KIDWELL |
| Wood Frame | 8/24/2021 | Partial Approval | JOHN KIDWELL |
| ELECTRICAL-Rough | 8/30/2021 | Approved | JOHN KIDWELL |
| HVAC-Rough | 8/30/2021 | Approved | JOHN KIDWELL |
| PLUMBING-Rough | 8/30/2021 | Not Ready for Inspection | JOHN KIDWELL |
| ELECTRICAL-Rough | 9/8/2021 | Approved | CARLOS MATAMOROS |
| HVAC-Rough | 9/8/2021 | Approved | CARLOS MATAMOROS |
| PLUMBING-Rough | 9/8/2021 | Approved | CARLOS MATAMOROS |
| Wood Frame | 9/8/2021 | Approved | CARLOS MATAMOROS |
| BUILDING-Rough-Frame | 9/14/2021 | Approved | JUAN VALENZUELA |
| Green Building Rough | 9/14/2021 | Approved | JUAN VALENZUELA |
| Insulation | 9/14/2021 | Approved | JUAN VALENZUELA |
| Interior/Exterior Lathing | 9/14/2021 | Partial Approval | JUAN VALENZUELA |
| Verify Sprinkler Sign Off | 9/14/2021 | Approved | JUAN VALENZUELA |
| Drywall Nailing | 5/2/2022 | Approved | JOHN KIDWELL |
| ELECTRICAL-Final | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| Final | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| Footing/Foundation/Slab | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| Green Building Final | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| HVAC-Final | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| PLUMBING-Final | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| SGSOV-Seismic Gas S/O Valve | 5/3/2022 | SGSOV Not Ready | JUAN VALENZUELA |
| Service/Power Release | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| Smoke Detectors | 5/3/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| ELECTRICAL-Final | 5/11/2022 | Approved | JOHN KIDWELL |
| Final | 5/11/2022 | Corrections Issued | JOHN KIDWELL |
| Footing/Foundation/Slab | 5/11/2022 | Approved | JOHN KIDWELL |
| Green Building Final | 5/11/2022 | Approved | JOHN KIDWELL |
| HVAC-Final | 5/11/2022 | Approved | JOHN KIDWELL |
| PLUMBING-Final | 5/11/2022 | Approved | JOHN KIDWELL |
| SGSOV-Seismic Gas S/O Valve | 5/11/2022 | SGSOV Approved | JOHN KIDWELL |
| Smoke Detectors | 5/11/2022 | Approved | JOHN KIDWELL |
| Final | 5/25/2022 | OK to Issue CofO | JOHN KIDWELL |