844 N FISKE ST 90272
Certificate Information: 844 N FISKE ST 90272
- Application / Permit
- 20010-20000-02176
- Plan Check / Job No.
- B20VN08551
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 30' X 77' (2) STORY SINGLE FAMILY DWELLING WITH ATTACHED GARAGE; EQUIPPED WITH NFPA 13-D FIRE SPRINKLERS THROUGHOUT
- Permit Issued
- Issued on 11/20/2020
- Issuing Office
- Valley
- Current Status
- CofO Issued on 7/22/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/30/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 7/23/2020 | SELLA BENYAMIN |
| Corrections Issued | 7/29/2020 | SELLA BENYAMIN |
| Quality Review Completed | 7/31/2020 | STEVEN KIM |
| Building Plans Picked Up | 8/7/2020 | APPLICANT |
| Plan Check Approved | 11/4/2020 | SELLA BENYAMIN |
| Issued | 11/20/2020 | APPLICANT |
| CofO in Progress | 7/12/2021 | JOHN KIDWELL |
| Permit Finaled | 7/22/2021 | VINCENT COTTON |
| CofO Issued | 7/22/2021 | VINCENT COTTON |
| Permit Finaled | 7/22/2021 | VINCENT COTTON |
Permit Application Clearance Information
| Address approval | Cleared | 8/24/2020 | ANTHONY MAINEZ |
| Permit | Cleared | 8/24/2020 | ANTHONY MAINEZ |
| Eng Process Fee Ord 176,300 | Cleared | 9/2/2020 | ANTHONY MAINEZ |
| Sewer availability | Cleared | 9/2/2020 | ANTHONY MAINEZ |
| Low Impact Development | Cleared | 10/19/2020 | ANDRES COVARRUBIAS |
| Trees in Parkway | Cleared | 10/19/2020 | JOHN KIM |
| Hydrant and Access approval | Cleared | 10/21/2020 | KURT CORRAL |
| GPI Written Notices | Cleared | 11/4/2020 | SELLA BENYAMIN |
| Grading Pre-Inspection | Cleared | 11/4/2020 | SELLA BENYAMIN |
| Roof/Waste drainage to street | Cleared | 11/12/2020 | DINAH GARIN |
Contact Information
| Contractor | J J P Construction Inc; Lic. No.: 960864-B | 7379 GREENBUSH AVE NORTH HOLLYWOOD, CA 91605 |
| Engineer | Wang,, Hongyu; Lic. No.: C72679 | 6270 MCLEOD DR STE 140 LAS VEGAS, NV 89120 |
Inspector Information
| TEMISTOCLES CAAL, (213) 653-1908 | Office Hours: 7:00-8:00 AM MON-FRI |
| JESUS PINEDA, (213) 653-1908 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 12/24/2020 | No Access for Inspection | KENNETH NAGLE |
| PLUMBING-Rough | 12/31/2020 | Corrections Issued | ANDREW NAVE |
| PLUMBING-Rough | 1/4/2021 | Partial Approval | ANDREW NAVE |
| Excavation/Setback/Form/Re-Bar | 1/11/2021 | Not Ready for Inspection | JOHN KIDWELL |
| Footing/Foundation/Slab | 1/11/2021 | Not Ready for Inspection | JOHN KIDWELL |
| Excavation/Setback/Form/Re-Bar | 1/13/2021 | Not Ready for Inspection | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 1/25/2021 | Conditional Approval | JOHN KIDWELL |
| Special/Order Compliance | 2/2/2021 | Partial Inspection | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 2/11/2021 | Not Ready for Inspection | JOHN KIDWELL |
| Deputy Wood Construction | 2/12/2021 | Partial Approval | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 2/12/2021 | Corrections Issued | JOHN KIDWELL |
| Interior/Exterior Lathing | 2/12/2021 | Not Ready for Inspection | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 2/16/2021 | Partial Approval | JOHN KIDWELL |
| HVAC-Rough | 2/23/2021 | Approved | JOHN KIDWELL |
| Floor/Roof Diaphrgm/Shear Wall | 2/24/2021 | Partial Approval | JOHN KIDWELL |
| Interior/Exterior Lathing | 2/24/2021 | Partial Approval | JOHN KIDWELL |
| Gas Test | 3/1/2021 | Partial Approval | JOHN KIDWELL |
| PLUMBING-Rough | 3/1/2021 | Partial Approval | JOHN KIDWELL |
| Special/Order Compliance | 3/1/2021 | Partial Inspection | JOHN KIDWELL |
| PLUMBING-Rough | 3/2/2021 | Corrections Issued | JOHN KIDWELL |
| ELECTRICAL-Rough | 3/4/2021 | Approved | JOHN KIDWELL |
| Green Building Rough | 3/4/2021 | Approved | JOHN KIDWELL |
| PLUMBING-Rough | 3/4/2021 | Approved | JOHN KIDWELL |
| Insulation | 3/5/2021 | Approved | JOHN KIDWELL |
| Drywall Nailing | 3/10/2021 | Approved | JOHN KIDWELL |
| Shower Pan | 3/11/2021 | Not Ready for Inspection | JOHN KIDWELL |
| Shower Pan | 3/16/2021 | Approved | ANDREW NAVE |
| Interior/Exterior Lathing | 3/22/2021 | Approved | ANDREW NAVE |
| PLUMBING-Final | 6/21/2021 | Approved | JOHN KIDWELL |
| Gas Test | 6/23/2021 | Partial Approval | ANDREW NAVE |
| HVAC-Final | 6/23/2021 | Corrections Issued | ANDREW NAVE |
| ELECTRICAL-Final | 6/28/2021 | Corrections Issued | CHRISTOPHER WILSON |
| Gas Test | 6/28/2021 | Approved | CHRISTOPHER WILSON |
| HVAC-Final | 6/29/2021 | Approved | JOHN KIDWELL |
| HVAC-Rough | 6/29/2021 | Approved | JOHN KIDWELL |
| Special/Order Compliance | 6/29/2021 | Approved | JOHN KIDWELL |
| ELECTRICAL-Final | 7/1/2021 | Approved | JOHN KIDWELL |
| Smoke Detectors | 7/1/2021 | Approved | JOHN KIDWELL |
| Special/Order Compliance | 7/1/2021 | Approved | JOHN KIDWELL |
| Verify Sprinkler Sign Off | 7/1/2021 | Approved | JOHN KIDWELL |
| BUILDING-Rough-Frame | 7/2/2021 | Approved | JOHN KIDWELL |
| Final | 7/2/2021 | OK to Issue CofO | JOHN KIDWELL |
| Footing/Foundation/Slab | 7/2/2021 | Approved | JOHN KIDWELL |
| Green Building Final | 7/2/2021 | Approved | JOHN KIDWELL |
| SGSOV-Seismic Gas S/O Valve | 7/2/2021 | SGSOV Approved | JOHN KIDWELL |
| Service/Power Release | 7/2/2021 | Approved | JOHN KIDWELL |