23926 W HAYNES ST 91307

Certificate Information: 23926 W HAYNES ST 91307

Application / Permit
20010-20000-01478
Plan Check / Job No.
B20VN00852
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
(N) 22'-8" X 22'-6" 2-STORY ACCESSORY DWELLING UNIT PER LAMC 12.22 A33.
Permit Issued
Issued on 10/6/2020
Issuing Office
Current Status
CofO Issued on 12/21/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 1/21/2020 APPLICANT
Green Plans Picked Up 2/21/2020 APPLICANT
Assigned to Plan Check Engineer 3/5/2020 SERGIO MUNIZ
Corrections Issued 3/9/2020 SERGIO MUNIZ
Quality Review Completed 3/20/2020 STEVEN KIM
Building Plans Picked Up 3/24/2020 APPLICANT
Applicant returned to address corrections 4/23/2020 SERGIO MUNIZ
Applicant returned to address corrections 5/18/2020 SERGIO MUNIZ
Applicant returned to address corrections 6/5/2020 SERGIO MUNIZ
Applicant returned to address corrections 8/20/2020 SERGIO MUNIZ
Plan Check Approved 9/18/2020 SERGIO MUNIZ
Issued 10/6/2020 APPLICANT
CofO in Progress 12/9/2021 TROY SANDERS
Permit Finaled 12/21/2021 JOHN JANSON
CofO Issued 12/21/2021 JOHN JANSON
Permit Finaled 12/21/2021 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 5/28/2020 ADRIAN CASTRO
Green Code Cleared 5/29/2020 MICHAEL AYERS
Hydrant and Access approval Cleared 7/16/2020 MATTHEW CRAIG
Low Impact Development Cleared 8/6/2020 ANDRES COVARRUBIAS
Roof/Waste drainage to street Cleared 8/7/2020 ADRIAN CASTRO
Eng Process Fee Ord 176,300 Cleared 8/10/2020 ADRIAN CASTRO
Sewer availability Cleared 8/10/2020 ADRIAN CASTRO

Contact Information

Contractor Owner-Builder       ,
Engineer Basma,, Ali J; Lic. No.: C53080 21500 WYANDOTTE ST 106      CANOGA PARK, CA 91303

Inspector Information

GEVORK IPCHYAN, (818) 774-4308 Office Hours: 7:00-8:00 AM MON-FRI
TROY SANDERS, (818) 774-4308 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Sewer 10/19/2020 Approved TROY SANDERS
Underground Mechanical 10/19/2020 Approved TROY SANDERS
Excavation/Setback/Form/Re-Bar 10/22/2020 Approved TROY SANDERS
Footing/Foundation/Slab 10/22/2020 Approved TROY SANDERS
BUILDING-Rough-Frame 12/24/2020 Not Ready for Inspection TROY SANDERS
Green Building Rough 12/24/2020 Not Ready for Inspection TROY SANDERS
MERV13>=Rough 12/24/2020 Approved TROY SANDERS
PLUMBING-Rough 12/24/2020 Approved TROY SANDERS
Verify Sprinkler Sign Off 12/24/2020 Approved TROY SANDERS
BUILDING-Rough-Frame 1/8/2021 Approved TROY SANDERS
ELECTRICAL-Rough 1/8/2021 Approved TROY SANDERS
Green Building Rough 1/8/2021 Approved TROY SANDERS
Insulation 1/8/2021 Approved TROY SANDERS
Interior/Exterior Lathing 1/8/2021 Approved TROY SANDERS
Shower Pan 1/8/2021 Approved TROY SANDERS
Drywall Nailing 4/28/2021 Approved TROY SANDERS
Final 9/27/2021 Corrections Issued TROY SANDERS
Green Building Final 9/27/2021 Approved TROY SANDERS
HVAC-Final 9/27/2021 Approved TROY SANDERS
MERV13>=Final 9/27/2021 Approved TROY SANDERS
PLUMBING-Final 9/27/2021 Approved TROY SANDERS
SGSOV-Seismic Gas S/O Valve 9/27/2021 SGSOV Approved TROY SANDERS
Service/Power Release 9/27/2021 Approved TROY SANDERS
Smoke Detectors 9/27/2021 Approved TROY SANDERS
Final 12/8/2021 OK to Issue CofO TROY SANDERS