24803 S LAKME AVE 90744

Certificate Information: 24803 S LAKME AVE 90744

Application / Permit
20010-10000-03750
Plan Check / Job No.
B20LA19029
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
PROPOSED ONE STORY ACCESSORRY DWELLING UNIT AT REAR OF THE LOT (800 SF max New Construction per State Law, CA Govt. Code 65852.2(e)(1)(B) and applicable part2 of LAMC 12.22 A.33 (c)-(d), (g))
Permit Issued
Issued on 3/16/2022
Issuing Office
Current Status
Issued on 3/16/2022
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 10/20/2020 APPLICANT
Assigned to Plan Check Engineer 10/30/2020 RACHEL BEYENE
Corrections Issued 11/4/2020 RACHEL BEYENE
Applicant returned to address corrections 8/17/2021 AUNG SOE
Applicant returned to address corrections 9/14/2021 FERNANDO FLORES
Applicant returned to address corrections 10/21/2021 SINA KHOSRAVI
Applicant returned to address corrections 11/29/2021 RACHEL BEYENE
Applicant returned to address corrections 12/28/2021 FERNANDO FLORES
Building Plans Picked Up 1/3/2022 APPLICANT
Plan Check Approved 1/31/2022 RICARDO RAMIREZ
Issued 3/16/2022 APPLICANT

Permit Application Clearance Information

Address approval Cleared 12/16/2020 CHINH DINH
Clean Up Green Up Cleared 1/11/2021 ANNA VIDAL
Eng Process Fee Ord 176,300 Cleared 1/11/2021 ERIK BEASLEY
Sewer availability Cleared 1/11/2021 ERIK BEASLEY
Hydrant and Access approval Cleared 2/12/2021 MATTHEW CRAIG
Low Impact Development Cleared 7/13/2021 SARAH YOUSSEF

Contact Information

Contractor Motec Engineering And Construction; Lic. No.: 621198-B 11852 MAC NAB STREET      GARDEN GROVE, CA 92841

Inspector Information

EUGENE CASSIDY, (310) 548-2508 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 3/22/2022 Corrections Issued EUGENE CASSIDY
Footing/Foundation/Slab 4/21/2022 Partial Approval EUGENE CASSIDY
METHANE-Barrier 4/21/2022 Not Ready for Inspection EUGENE CASSIDY
METHANE-Subgrade 4/21/2022 Not Ready for Inspection EUGENE CASSIDY
Footing/Foundation/Slab 5/18/2022 Not Ready for Inspection EUGENE CASSIDY
METHANE-Barrier 5/18/2022 Not Ready for Inspection EUGENE CASSIDY
METHANE-Subgrade 5/18/2022 Corrections Issued EUGENE CASSIDY
Deputy Methane Barrier 6/8/2022 Partial Approval EUGENE CASSIDY
Deputy Methane Barrier 6/10/2022 Partial Approval EUGENE CASSIDY
Footing/Foundation/Slab 7/5/2022 Conditional Approval EUGENE CASSIDY
METHANE-Barrier 7/5/2022 Partial Approval EUGENE CASSIDY
METHANE-Subgrade 7/5/2022 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 9/14/2022 Corrections Issued EUGENE CASSIDY
ELECTRICAL-Rough 9/14/2022 Partial Approval EUGENE CASSIDY
Green Building Rough 9/14/2022 Not Ready for Inspection EUGENE CASSIDY
METHANE-Rough 9/14/2022 Partial Approval EUGENE CASSIDY
PLUMBING-Rough 9/14/2022 Not Ready for Inspection EUGENE CASSIDY
Verify Sprinkler Sign Off 9/14/2022 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 10/3/2022 Not Ready for Inspection EUGENE CASSIDY
Green Building Rough 10/3/2022 Approved EUGENE CASSIDY
Interior/Exterior Lathing 10/3/2022 Partial Approval EUGENE CASSIDY
METHANE-Rough 10/3/2022 Approved EUGENE CASSIDY
Insulation 10/13/2022 Approved EUGENE CASSIDY
Drywall Nailing 10/28/2022 Approved EUGENE CASSIDY
HVAC-Rough 10/28/2022 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 2/24/2023 Approved EUGENE CASSIDY
Final 2/24/2023 Corrections Issued EUGENE CASSIDY
Footing/Foundation/Slab 2/24/2023 Approved EUGENE CASSIDY
Green Building Final 2/24/2023 Not Ready for Inspection EUGENE CASSIDY
METHANE-Barrier 2/24/2023 Approved EUGENE CASSIDY
SGSOV-Seismic Gas S/O Valve 2/24/2023 SGSOV Not Ready EUGENE CASSIDY
Service/Power Release 2/24/2023 Not Ready for Inspection EUGENE CASSIDY
Smoke Detectors 2/24/2023 Not Ready for Inspection EUGENE CASSIDY
Final 3/24/2023 Corrections Issued EUGENE CASSIDY
Green Building Final 3/24/2023 Not Ready for Inspection EUGENE CASSIDY
SGSOV-Seismic Gas S/O Valve 3/24/2023 SGSOV Approved EUGENE CASSIDY
Service/Power Release 3/24/2023 Not Ready for Inspection EUGENE CASSIDY
Smoke Detectors 3/24/2023 Approved EUGENE CASSIDY
Final 4/4/2023 Corrections Issued EUGENE CASSIDY
Green Building Final 4/4/2023 Approved EUGENE CASSIDY
Service/Power Release 4/4/2023 Not Required EUGENE CASSIDY
Final 8/23/2023 Corrections Issued EUGENE CASSIDY
Final 5/1/2024 Corrections Issued EUGENE CASSIDY