1322-1322 1/2 W 37TH PL 90007
Certificate Information: 1322-1322 1/2 W 37TH PL 90007
- Application / Permit
- 20010-10000-03168
- Plan Check / Job No.
- B20LA16646
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- NEW 2 STORY DUPLEX (AT REAR). BUILDING TO BE EQUIPPED WITH SPRINLER SYS NFPA 13-D
- Permit Issued
- Issued on 12/1/2021
- Issuing Office
- Metro
- Current Status
- CofO Issued on 8/11/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 10/14/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 10/22/2020 | MONICA RAMIREZ |
| Corrections Issued | 10/26/2020 | MONICA RAMIREZ |
| Quality Review Completed | 11/6/2020 | TU HUA |
| Building Plans Picked Up | 11/13/2020 | APPLICANT |
| Applicant returned to address corrections | 7/29/2021 | MONICA RAMIREZ |
| Applicant returned to address corrections | 9/2/2021 | MONICA RAMIREZ |
| Plan Check Approved | 10/26/2021 | MONICA RAMIREZ |
| Issued | 12/1/2021 | APPLICANT |
| CofO in Progress | 8/9/2022 | SABAS ALONSO |
| Permit Finaled | 8/11/2022 | DEROLD HAUFF |
| CofO Issued | 8/11/2022 | DEROLD HAUFF |
| Permit Finaled | 8/11/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 12/16/2020 | CECILIO NAVARRO |
| Highway dedication | Cleared | 12/16/2020 | CECILIO NAVARRO |
| Eng Process Fee Ord 176,300 | Cleared | 12/22/2020 | CECILIO NAVARRO |
| Sewer availability | Cleared | 12/22/2020 | CECILIO NAVARRO |
| ZI | Cleared | 4/27/2021 | LOUIS ORTEGA |
| Hydrant and Access approval | Cleared | 6/9/2021 | JOHN CONNEALLY |
| Low Impact Development | Cleared | 7/9/2021 | TA ANH |
| Roof/Waste drainage to street | Cleared | 7/15/2021 | CECILIO NAVARRO |
Contact Information
| Contractor | Baksh Construction Inc; Lic. No.: 910533-B | 4 HILLCREST MANOR ROLLING HILLS ESTATES, CA 90274 |
| Engineer | Inman,, Donald J; Lic. No.: C11888 | 5131 FOX HILLS AVENUE BUENA PARK, CA 90621 |
Inspector Information
| SABAS ALONSO, (213) 202-3468 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/8/2021 | Approved | SABAS ALONSO |
| BUILDING-Rough-Frame | 12/28/2021 | Partial Approval | HORACE FULTZ |
| Green Building Rough | 12/28/2021 | Not Ready for Inspection | HORACE FULTZ |
| Insulation | 12/28/2021 | Partial Approval | HORACE FULTZ |
| PLUMBING-Rough | 12/28/2021 | Partial Approval | HORACE FULTZ |
| Verify Sprinkler Sign Off | 12/28/2021 | Not Ready for Inspection | HORACE FULTZ |
| Floor/Roof Diaphrgm/Shear Wall | 1/3/2022 | Approved | SABAS ALONSO |
| Floor/Roof Diaphrgm/Shear Wall | 1/13/2022 | Partial Approval | AMY COLIN |
| Floor/Roof Diaphrgm/Shear Wall | 2/1/2022 | Approved | SABAS ALONSO |
| HVAC-Rough | 3/22/2022 | Corrections Issued | SABAS ALONSO |
| Interior/Exterior Lathing | 3/22/2022 | Not Ready for Inspection | SABAS ALONSO |
| PLUMBING-Rough | 3/22/2022 | Corrections Issued | SABAS ALONSO |
| BUILDING-Rough-Frame | 3/29/2022 | Approved | HORACE FULTZ |
| ELECTRICAL-Rough | 3/29/2022 | Approved | HORACE FULTZ |
| Green Building Rough | 3/29/2022 | Approved | HORACE FULTZ |
| HVAC-Rough | 3/29/2022 | Approved | HORACE FULTZ |
| PLUMBING-Rough | 3/29/2022 | Approved | HORACE FULTZ |
| Rough-Elec/Plmb/HVAC | 3/29/2022 | Approved | HORACE FULTZ |
| Verify Sprinkler Sign Off | 3/29/2022 | Approved | HORACE FULTZ |
| Insulation | 4/4/2022 | Corrections Issued | SABAS ALONSO |
| Interior/Exterior Lathing | 4/4/2022 | Partial Approval | SABAS ALONSO |
| Drywall Nailing | 4/13/2022 | Approved | HORACE FULTZ |
| Interior/Exterior Lathing | 4/13/2022 | Approved | HORACE FULTZ |
| ELECTRICAL-Final | 7/11/2022 | Not Ready for Inspection | SABAS ALONSO |
| PLUMBING-Final | 7/11/2022 | Approved | SABAS ALONSO |
| Final | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| Green Building Final | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| HVAC-Final | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| Pre-Inspection | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| SGSOV-Seismic Gas S/O Valve | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| Service/Power Release | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| Smoke Detectors | 7/12/2022 | No Access for Inspection | SABAS ALONSO |
| ELECTRICAL-Final | 7/27/2022 | Approved | SABAS ALONSO |
| Final | 7/27/2022 | Not Ready for Inspection | SABAS ALONSO |
| Green Building Final | 7/27/2022 | Approved | SABAS ALONSO |
| HVAC-Final | 7/27/2022 | Approved | SABAS ALONSO |
| SGSOV-Seismic Gas S/O Valve | 7/27/2022 | SGSOV Approved | SABAS ALONSO |
| Service/Power Release | 7/27/2022 | Not Ready for Inspection | SABAS ALONSO |
| Smoke Detectors | 7/27/2022 | Approved | SABAS ALONSO |
| Final | 8/4/2022 | Corrections Issued | SABAS ALONSO |
| Service/Power Release | 8/4/2022 | Not Ready for Inspection | SABAS ALONSO |
| Final | 8/9/2022 | OK to Issue CofO | SABAS ALONSO |
| Service/Power Release | 8/9/2022 | Approved | SABAS ALONSO |