330 1/2 N LUCERNE BLVD 90004

Certificate Information: 330 1/2 N LUCERNE BLVD 90004

Application / Permit
20010-10000-02025
Plan Check / Job No.
B20LA10543
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
NEW DETACHED ADU (458 SF) PER 800 SF MAX PRE STATE ORDINANCE "COMPLY WITH DEPARTMENT ORDER effective date 04/09/2019. PERMIT WILL EXPIRE 30 DAYS FROM ISSUANCE DATE". CEIS Case Number is 852684.
Permit Issued
Issued on 11/25/2020
Issuing Office
Current Status
CofO Issued on 6/1/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/16/2020 APPLICANT
Assigned to Plan Check Engineer 7/10/2020 AUNG SOE
Corrections Issued 7/21/2020 AUNG SOE
Quality Review Completed 8/6/2020 HERNAN ARREOLA
Building Plans Picked Up 8/18/2020 APPLICANT
Applicant returned to address corrections 10/28/2020 AUNG SOE
Plan Check Approved 10/29/2020 AUNG SOE
Issued 11/25/2020 APPLICANT
CofO in Progress 2/24/2021 CHRIS CHRISTENSEN
Permit Finaled 6/1/2021 DEROLD HAUFF
CofO Issued 6/1/2021 DEROLD HAUFF
Permit Finaled 6/1/2021 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 9/23/2020 WALLIE JONG
Roof/Waste drainage to street Cleared 9/23/2020 WALLIE JONG
Eng Process Fee Ord 176,300 Cleared 9/24/2020 WALLIE JONG
Low Impact Development Cleared 9/24/2020 MARTIN FRAGOSO
Sewer availability Cleared 9/24/2020 WALLIE JONG
Hydrant and Access approval Cleared 10/7/2020 KURT CORRAL
Green Code Cleared 10/29/2020 AUNG SOE

Contact Information

Contractor Solid Construction Company Inc; Lic. No.: 836983-B 883 CRENSHAW BLVD      LOS ANGELES, CA 90005
Engineer Park,, Juntae; Lic. No.: C65104 3055 WILSHIRE BLVD 880      LOS ANGELES, CA 90010
Engineer Zhong,, Raymond Meng; Lic. No.: M27635 2416 W VALLEY BLVD      ALHAMBRA, CA 91803

Inspector Information

JEFFREY MEAD, (213) 202-3240 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Reinf. Concrete 11/30/2020 No Access for Inspection ELMER BLAND
Excavation/Setback/Form/Re-Bar 12/1/2020 Approved CHRIS CHRISTENSEN
Footing/Foundation/Slab 12/1/2020 Approved CHRIS CHRISTENSEN
METHANE-Barrier 12/1/2020 Approved CHRIS CHRISTENSEN
METHANE-Subgrade 12/1/2020 Approved CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 12/9/2020 Partial Approval CHRIS CHRISTENSEN
METHANE-Final 12/9/2020 Approved CHRIS CHRISTENSEN
Underground Mechanical 12/9/2020 Approved CHRIS CHRISTENSEN
BUILDING-Rough-Frame 12/23/2020 Partial Approval CHRIS CHRISTENSEN
ELECTRICAL-Rough 12/23/2020 Corrections Issued CHRIS CHRISTENSEN
HVAC-Rough 12/23/2020 Corrections Issued CHRIS CHRISTENSEN
PLUMBING-Rough 12/23/2020 Approved CHRIS CHRISTENSEN
Verify Sprinkler Sign Off 12/23/2020 Partial Approval CHRIS CHRISTENSEN
Floor/Roof Diaphrgm/Shear Wall 12/24/2020 Partial Approval CHRIS CHRISTENSEN
BUILDING-Rough-Frame 12/29/2020 Conditional Approval CHRIS CHRISTENSEN
ELECTRICAL-Rough 12/29/2020 Approved CHRIS CHRISTENSEN
HVAC-Rough 12/29/2020 Approved CHRIS CHRISTENSEN
Insulation 12/29/2020 Conditional Approval CHRIS CHRISTENSEN
Interior/Exterior Lathing 12/29/2020 Approved CHRIS CHRISTENSEN
Drywall Nailing 1/5/2021 Approved CHRIS CHRISTENSEN
BUILDING-Rough-Frame 2/16/2021 Approved CHRIS CHRISTENSEN
ELECTRICAL-Final 2/16/2021 Approved CHRIS CHRISTENSEN
Final 2/16/2021 Corrections Issued CHRIS CHRISTENSEN
HVAC-Final 2/16/2021 Approved CHRIS CHRISTENSEN
PLUMBING-Final 2/16/2021 Approved CHRIS CHRISTENSEN
SGSOV-Seismic Gas S/O Valve 2/16/2021 SGSOV Approved CHRIS CHRISTENSEN
Service/Power Release 2/16/2021 Not Required CHRIS CHRISTENSEN
Smoke Detectors 2/16/2021 Approved CHRIS CHRISTENSEN
Verify Sprinkler Sign Off 2/16/2021 Approved CHRIS CHRISTENSEN
Final 2/23/2021 OK to Issue CofO CHRIS CHRISTENSEN