11842 S TEALE ST 90230
Certificate Information: 11842 S TEALE ST 90230
- Application / Permit
- 20010-10000-01944
- Plan Check / Job No.
- B20LA10090
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- Commercial
- Primary Use
- (16) Industrial Center
- Work Description
- NEW 2 -STORY W/ A MEZZANINE INDUSTRIAL BUILDING: 1ST FLOOR GARAGE AND MANUFACTURE, 2ND AND MEZZANINE FLOORS MANUFACTURE AND ACCESSORY OFFICE, (core and shell only) Not a uphostered funiture or matresses use.
- Permit Issued
- Issued on 12/16/2022
- Issuing Office
- Metro
- Current Status
- Issued on 12/16/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 6/9/2020 | APPLICANT |
| Assigned to Plan Check Engineer | 6/26/2020 | SAM CHANG |
| Disabled Access Plans Picked Up | 7/14/2020 | APPLICANT |
| Corrections Issued | 8/5/2020 | SAM CHANG |
| Quality Review Completed | 8/6/2020 | JASON HEALEY |
| Building Plans Picked Up | 8/12/2020 | APPLICANT |
| Applicant returned to address corrections | 4/30/2021 | SAM CHANG |
| Applicant returned to address corrections | 6/23/2021 | SAM CHANG |
| Applicant returned to address corrections | 12/3/2021 | SAM CHANG |
| Applicant returned to address corrections | 7/6/2022 | SAM CHANG |
| Applicant returned to address corrections | 9/14/2022 | SAM CHANG |
| Applicant returned to address corrections | 11/10/2022 | SAM CHANG |
| Plan Check Approved | 12/9/2022 | SAM CHANG |
| Green Plans Picked Up | 12/9/2022 | APPLICANT |
| Issued | 12/16/2022 | APPLICANT |
Permit Application Clearance Information
| Hydrant and Access approval | Cleared | 8/11/2020 | MATTHEW CRAIG |
| Bicycle Parking | Cleared | 9/17/2020 | TRACY TATE |
| Sewer availability | Cleared | 9/17/2020 | TRACY TATE |
| Eng Process Fee Ord 176,300 | Cleared | 9/18/2020 | TRACY TATE |
| Permit | Cleared | 9/22/2020 | TRACY TATE |
| Miscellaneous | Cleared | 3/30/2021 | MAXFIELD VERMY |
| Trees in Parkway | Cleared | 5/25/2021 | JOHN KIM |
| Green Code | Cleared | 7/20/2021 | AARON COSTA |
| Low Impact Development | Cleared | 5/5/2022 | JORGE MEJIA LEMUS |
| Specific Plan | Cleared | 7/10/2022 | PEDRO AYALA |
| Work Adjacent to Public Way | Cleared | 7/27/2022 | SAUL GARCIA |
| Roof/Waste drainage to street | Cleared | 8/4/2022 | DINAH GARIN |
| Specific Plan | Cleared | 9/7/2022 | SHASHA YU |
| ZI | Cleared | 9/7/2022 | SHASHA YU |
| Mechanical Car Lift | Cleared | 11/7/2022 | MENOA AGHAJANI |
| DAS Clearance | Cleared | 12/8/2022 | SAM CHANG |
Contact Information
| Architect | Scott,, Jerome Douglas; Lic. No.: C25139 | 1010 E ACACIA AVE EL SEGUNDO, CA 90245 |
| Contractor | Simpson Richard A Construction; Lic. No.: 745774-B | 2114 WESTMINSTER AVE COSTA MESA, CA 92627 |
| Engineer | Chen,, Jeff Y; Lic. No.: S4699 | 17500 REDHILL AVENUE SUITE 240 IRVINE, CA 92614 |
| Engineer | Minas,, Caro Jolfaie; Lic. No.: GE601 | 4742 SAN FERNANDO RD GLENDALE, CA 91204 |
Inspector Information
| VASIL MIHALEV, (310) 914-3920 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 2/8/2023 | Approved | DERRICK SPENCER |
| Footing/Foundation/Slab | 6/21/2023 | Not Ready for Inspection | NICK LAROCCA |
| METHANE-Barrier | 6/21/2023 | Not Ready for Inspection | NICK LAROCCA |
| METHANE-Subgrade | 6/21/2023 | Not Ready for Inspection | NICK LAROCCA |
| Footing/Foundation/Slab | 6/23/2023 | Partial Approval | NICK LAROCCA |
| METHANE-Barrier | 6/23/2023 | Not Ready for Inspection | NICK LAROCCA |
| METHANE-Subgrade | 6/23/2023 | Not Ready for Inspection | NICK LAROCCA |
| Footing/Foundation/Slab | 6/29/2023 | Partial Inspection | NICK LAROCCA |
| METHANE-Barrier | 6/29/2023 | Not Ready for Inspection | NICK LAROCCA |
| METHANE-Subgrade | 6/29/2023 | Not Ready for Inspection | NICK LAROCCA |
| Footing/Foundation/Slab | 7/10/2023 | Partial Approval | DERRICK SPENCER |
| METHANE-Barrier | 7/10/2023 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Subgrade | 7/10/2023 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 11/9/2023 | Partial Approval | ALAN NOVAK |
| METHANE-Barrier | 11/9/2023 | Approved | ALAN NOVAK |
| METHANE-Subgrade | 11/9/2023 | Approved | ALAN NOVAK |
| Footing/Foundation/Slab | 11/22/2023 | Partial Approval | DERRICK SPENCER |
| Footing/Foundation/Slab | 11/28/2023 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 11/30/2023 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 12/4/2023 | Partial Approval | DERRICK SPENCER |
| Green Building Rough | 8/8/2024 | Not Ready for Inspection | GRANT WOODS |
| METHANE-Rough | 8/8/2024 | Not Ready for Inspection | GRANT WOODS |
| Verify Sprinkler Sign Off | 8/8/2024 | Not Ready for Inspection | GRANT WOODS |
| Wood Frame | 8/8/2024 | Not Ready for Inspection | GRANT WOODS |
| Footing/Foundation/Slab | 12/4/2024 | Partial Approval | DERRICK SPENCER |
| Footing/Foundation/Slab | 6/16/2025 | Partial Approval | DERRICK SPENCER |
| Final | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| Footing/Foundation/Slab | 11/24/2025 | Partial Approval | DERRICK SPENCER |
| Green Building Final | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| Green Building Rough | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Final | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Rough | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| SGSOV-Seismic Gas S/O Valve | 11/24/2025 | SGSOV Approved | DERRICK SPENCER |
| Smoke Detectors | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| Verify Sprinkler Sign Off | 11/24/2025 | Not Ready for Inspection | DERRICK SPENCER |
| Wood Frame | 11/24/2025 | Partial Approval | DERRICK SPENCER |
| Footing/Foundation/Slab | 1/12/2026 | Approved | DERRICK SPENCER |
| Pre-Inspection | 1/22/2026 | Approved | VASIL MIHALEV |
| Final | 2/2/2026 | Not Ready for Inspection | DERRICK SPENCER |
| Green Building Final | 2/2/2026 | Approved | DERRICK SPENCER |
| Green Building Rough | 2/2/2026 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Final | 2/2/2026 | Not Ready for Inspection | DERRICK SPENCER |
| METHANE-Rough | 2/2/2026 | Approved | DERRICK SPENCER |
| Smoke Detectors | 2/2/2026 | Approved | DERRICK SPENCER |
| Verify Sprinkler Sign Off | 2/2/2026 | Approved | DERRICK SPENCER |
| Wood Frame | 2/2/2026 | No Access for Inspection | DERRICK SPENCER |