3933 N HAYVENHURST AVE 91436
Certificate Information: 3933 N HAYVENHURST AVE 91436
- Application / Permit
- 19047-30000-01523
- Plan Check / Job No.
- B19WL05093
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- (N) SWIMMING POOL & SPA AT REAR OF THE LOT. PER ENGINEERED DESIGN.
- Permit Issued
- Issued on 1/9/2020
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 2/19/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 9/9/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 9/18/2019 | REZA HAGHIGHAT |
| Corrections Issued | 9/23/2019 | REZA HAGHIGHAT |
| Quality Review Completed | 10/4/2019 | KAMRAN GHOTBI RAVANDI |
| Building Plans Picked Up | 10/4/2019 | APPLICANT |
| Plan Check Approved | 1/8/2020 | REZA HAGHIGHAT |
| Issued | 1/9/2020 | LADBS |
| CofO in Progress | 9/12/2020 | RONALD COWAN |
| Permit Finaled | 2/19/2021 | RONALD MYRICK |
| CofO Issued | 2/19/2021 | RONALD MYRICK |
| Permit Finaled | 2/19/2021 | RONALD MYRICK |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 1/6/2020 | REZA HAGHIGHAT |
Contact Information
| Contractor | Pacific Blue Pools & Spas; Lic. No.: 565996-C53 | 13638 DONNYBROOK LANE MOORPARK, CA 93021 |
| Engineer | Azizisefat,, Solayman; Lic. No.: C57840 | 19510 VENTURA BLVD STE 110 TARZANA, CA 91356 |
| Geologist | , ; Lic. No.: GEO2131 | 20312 TAU PLACE CHATSWORTH, CA 91311 |
| Geologist | Haenschke,, Eirik Francis; Lic. No.: EG1597 | 9616 GIERSON AVE CHATSWORTH, CA 91311 |
Inspector Information
| THOMAS FINNILA, (818) 774-4324 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Gunite | 3/10/2020 | Corrections Issued | RONALD COWAN |
| Pre-Gunite | 3/19/2020 | Approved | RONALD COWAN |
| Deputy Shotcrete | 3/25/2020 | Approved | RONALD COWAN |
| Deck | 4/16/2020 | Approved | RONALD COWAN |
| Rough-Mechanical | 4/22/2020 | Approved | RONALD COWAN |
| Enclosure/Fence | 6/5/2020 | Approved | RONALD COWAN |
| Pool Equipment Noise Test | 6/26/2020 | Approved | ALFREDO FLORES |
| Excavation/Setback/Form/Re-Bar | 8/28/2020 | Not Ready for Inspection | DAVID SCANTLIN |
| Final | 8/28/2020 | Not Ready for Inspection | DAVID SCANTLIN |
| SGSOV-Seismic Gas S/O Valve | 8/28/2020 | SGSOV Not Ready | DAVID SCANTLIN |
| Excavation/Setback/Form/Re-Bar | 9/11/2020 | Approved | RONALD COWAN |
| Final | 9/11/2020 | OK to Issue CofO | RONALD COWAN |
| SGSOV-Seismic Gas S/O Valve | 9/11/2020 | SGSOV Approved | RONALD COWAN |