13206 W DEWEY ST 90066

Certificate Information: 13206 W DEWEY ST 90066

Application / Permit
19030-30000-08638
Plan Check / Job No.
B19WL07386
Group
Building
Type
Grading
Sub-Type
1 or 2 Family Dwelling
Primary Use
(70) Grading - Hillside
Work Description
Grading for (n) retaining wall and (n) house
Permit Issued
Issued on 3/11/2020
Issuing Office
West Los Angeles
Current Status
Permit Finaled on 7/21/2021

Permit Application Status History

Submitted 12/31/2019 APPLICANT
Green Plans Picked Up 1/15/2020 APPLICANT
Assigned to Plan Check Engineer 1/30/2020 KAVIAN REFAHI
Corrections Issued 2/3/2020 KAVIAN REFAHI
Quality Review Completed 2/13/2020 KAMRAN GHOTBI RAVANDI
Building Plans Picked Up 2/20/2020 APPLICANT
Plan Check Approved 3/11/2020 KAVIAN REFAHI
Issued 3/11/2020 LADBS
Permit Finaled 7/20/2021 AL GAMBLE

Permit Application Clearance Information

Grading Pre-Inspection Cleared 2/1/2020 KAVIAN REFAHI
Excavation more than 5-ft deep Cleared 3/11/2020 CALOSHA APPROVED

Contact Information

Contractor T J C Home Builders Llc; Lic. No.: 1025507-B 26880 ALISO VIEJO PKWY STE 100      ALISO VIEJO, CA 92656
Engineer Haddad,, Raymond Mounir; Lic. No.: GE2985 17106 CEREDO PL      GRANADA HILLS, CA 91344
Engineer Messiha,, Hany Gamil; Lic. No.: C56766 19648 MULBERRY DR      WALNUT, CA 91789

Inspector Information

JOHNNY MIRANDA, (310) 914-3937 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Initial Grading 7/13/2020 Not Ready for Inspection MATTHEW JENKINS
Initial Grading 7/14/2020 Corrections Issued MATTHEW JENKINS
Initial Grading 7/21/2020 Approved JONATHAN HOM
Bottom/Toe 7/27/2020 Corrections Issued MATTHEW JENKINS
Excavation 7/28/2020 Partial Approval JONATHAN HOM
Sub-Drain 8/7/2020 Partial Inspection JONATHAN HOM
Bottom/Toe 8/10/2020 Corrections Issued MATTHEW JENKINS
Sub-Drain 8/10/2020 Partial Approval MATTHEW JENKINS
Rough 8/31/2020 Partial Inspection MATTHEW JENKINS
Rough 9/2/2020 Partial Approval MATTHEW JENKINS
Bottom/Toe 9/18/2020 Not Ready for Inspection JONATHAN HOM
Final 9/18/2020 Not Ready for Inspection JONATHAN HOM
Rough 9/18/2020 Not Ready for Inspection JONATHAN HOM
Approved Compaction Report 10/6/2020 Approved KIRK LINKLATER
Bottom/Toe 10/8/2020 Not Ready for Inspection KIRK LINKLATER
Final 10/8/2020 Not Ready for Inspection KIRK LINKLATER
Rough 10/8/2020 Not Ready for Inspection KIRK LINKLATER
Bottom/Toe 7/12/2021 Not Ready for Inspection AL GAMBLE
Final 7/12/2021 Not Ready for Inspection AL GAMBLE
Rough 7/12/2021 Not Ready for Inspection AL GAMBLE
Bottom/Toe 7/14/2021 Approved AL GAMBLE
Final 7/14/2021 Not Ready for Inspection AL GAMBLE
Rough 7/14/2021 Approved AL GAMBLE
Final 7/20/2021 Permit Finaled AL GAMBLE