3421 N FLETCHER DR 90065

Certificate Information: 3421 N FLETCHER DR 90065

Application / Permit
19030-10000-03221
Plan Check / Job No.
G19LA00122
Group
Building
Type
Grading
Sub-Type
1 or 2 Family Dwelling
Primary Use
(70) Grading - Hillside
Work Description
ROUGH GRADING FOR 17 LOT SUBDIVISION. CUT= 20 CY; FILL = 2,180; IMPORT= 2,450; R&R = 2,900 CY. BF 200003 APPROVED FOR AN IMPORT OF 2,450 CUBIC YARDS
Permit Issued
Issued on 1/14/2021
Issuing Office
Current Status
Permit Finaled on 3/14/2025

Permit Application Status History

Submitted 5/22/2019 APPLICANT
Assigned to Plan Check Engineer 5/29/2019 DAN RYAN EVANGELISTA
Corrections Issued 5/29/2019 DAN RYAN EVANGELISTA
Applicant returned to address corrections 10/13/2020 DAN RYAN EVANGELISTA
Plan Check Approved 10/21/2020 DAN RYAN EVANGELISTA
Issued 1/14/2021 APPLICANT
Permit Finaled 3/13/2025 LANNY MERRICK

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 8/20/2019 JEANETTE VONG
Grading Pre-Inspection Cleared 12/16/2019 LUIS ALVAREZ
Low Impact Development Cleared 4/29/2020 JORGE MEJIA LEMUS
Permit Cleared 4/30/2020 EMIL KYUPELYAN
Roof/Waste drainage to street Cleared 4/30/2020 EMIL KYUPELYAN
Haul Route Cleared 7/8/2020 VERONICA LOPEZ
Tract Map conditions Cleared 9/10/2020 LOUIS ORTEGA
Greywater Systems Not Cleared 3/26/2025 Department of Building and Safety
Greywater Systems Not Cleared 3/26/2025 Department of Building and Safety
Hold Cleared 3/26/2025 SAUL GAMBOA
Hold Cleared 3/26/2025 SAUL GAMBOA

Contact Information

Contractor Planet Home Development Inc; Lic. No.: 975236-B 1048 IRVINE AVENUE #421      NEWPORT BEACH, CA 92660
Engineer Walter,, Scott John; Lic. No.: GE2476 14428 HAMLIN ST STE 200      VAN NUYS, CA 91401

Inspector Information

JONATHAN HOM, (213) 482-7452 Office Hours: 7:00-8:00 AM MON-FRI
ROBERT HUGHES, (213) 482-7452 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Bottom/Toe 1/21/2021 Partial Approval ROBERT HUGHES
Initial Grading 1/21/2021 Approved ROBERT HUGHES
Bottom/Toe 1/22/2021 Partial Approval ROBERT HUGHES
Bottom/Toe 1/26/2021 Not Ready for Inspection ROBERT HUGHES
Bottom/Toe 2/12/2021 Partial Approval ROBERT HUGHES
Special/Order Compliance 4/12/2022 Partial Approval ROBERT HUGHES
Approved Compaction Report 4/13/2022 Corrections Issued ROBERT HUGHES
Approved Compaction Report 4/18/2022 Approved ROBERT HUGHES
Bottom/Toe 4/27/2023 Not Ready for Inspection ROBERT HUGHES
Final 4/27/2023 Corrections Issued ROBERT HUGHES
Rough 4/27/2023 Not Ready for Inspection ROBERT HUGHES
SUSMP-Std. Urban Storm Water 4/27/2023 Approved ROBERT HUGHES
Bottom/Toe 10/17/2023 Approved ROBERT HUGHES
Final 10/17/2023 Not Ready for Inspection ROBERT HUGHES
Rough 10/17/2023 Not Ready for Inspection ROBERT HUGHES
Final 10/19/2023 Not Ready for Inspection ROBERT HUGHES
Rough 10/19/2023 Not Ready for Inspection ROBERT HUGHES
Final 10/31/2023 Not Ready for Inspection ROBERT HUGHES
Rough 10/31/2023 Not Ready for Inspection ROBERT HUGHES
Final 2/20/2024 Not Ready for Inspection RUSSELL BONVOULOIR
Rough 2/20/2024 Partial Inspection RUSSELL BONVOULOIR
Final 7/22/2024 Not Ready for Inspection LANNY MERRICK
Rough 7/22/2024 Not Ready for Inspection LANNY MERRICK
Final 7/26/2024 Not Ready for Inspection LANNY MERRICK
Rough 7/26/2024 Not Ready for Inspection LANNY MERRICK
Final 7/30/2024 Not Ready for Inspection LANNY MERRICK
Rough 7/30/2024 Not Ready for Inspection LANNY MERRICK
Final 3/13/2025 Permit Finaled LANNY MERRICK
Rough 3/13/2025 Approved LANNY MERRICK