446 W VISTA GLORIOSA DR 90065
Certificate Information: 446 W VISTA GLORIOSA DR 90065
- Application / Permit
- 19030-10000-00773
- Plan Check / Job No.
- B19LA02633
- Group
- Building
- Type
- Grading
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (70) Grading - Hillside
- Work Description
- SITE GRADING FOR NEW THREE STORY SINGLE FAMILY AND RETAINING WALLS.
- Permit Issued
- Issued on 10/1/2021
- Issuing Office
- Metro
- Current Status
- Permit Finaled on 7/26/2023
Permit Application Status History
| Submitted | 2/8/2019 | APPLICANT |
| Assigned to Plan Check Engineer | 2/28/2019 | SAMUEL GONZALEZ |
| Corrections Issued | 3/7/2019 | SAMUEL GONZALEZ |
| Quality Review Completed | 3/28/2019 | ARMEN JIVALAGIAN |
| Green Plans Picked Up | 8/21/2020 | APPLICANT |
| Plan Check Approved | 11/12/2020 | SAMUEL GONZALEZ |
| Issued | 10/1/2021 | APPLICANT |
| Building Plans Picked Up | 10/4/2021 | APPLICANT |
| Permit Finaled | 7/25/2023 | RUSSELL BONVOULOIR |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 7/26/2020 | CECILIO NAVARRO |
| Work Adjacent to Public Way | Cleared | 7/31/2020 | ROSA SILVA |
Contact Information
| Contractor | Storrey Building Inc; Lic. No.: 906804-B | 19327 VISTA GRANDE WAY NORTHRIDGE, CA 91326 |
Inspector Information
| JONATHAN HOM, (213) 482-7452 | Office Hours: 7:00-8:00 AM MON-FRI |
| ROBERT HUGHES, (213) 482-7452 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Initial Grading | 10/8/2021 | Partial Approval | ROBERT HUGHES |
| Bottom/Toe | 10/14/2021 | Not Ready for Inspection | ALEXANDER HELFER |
| Excavation | 10/14/2021 | Not Ready for Inspection | ALEXANDER HELFER |
| Bottom/Toe | 10/20/2021 | Not Ready for Inspection | LANNY MERRICK |
| Excavation | 10/20/2021 | Partial Approval | LANNY MERRICK |
| Sub-Drain | 2/11/2022 | Corrections Issued | ROBERT HUGHES |
| Bottom/Toe | 6/10/2022 | Not Ready for Inspection | ROBERT HUGHES |
| Excavation | 6/10/2022 | Partial Approval | ROBERT HUGHES |
| Bottom/Toe | 6/21/2022 | Not Ready for Inspection | ROBERT HUGHES |
| Rough | 7/12/2022 | Not Ready for Inspection | ROBERT HUGHES |
| Sub-Drain | 8/16/2022 | Partial Approval | ROBERT HUGHES |
| Approved Compaction Report | 3/20/2023 | Approved | KIRK LINKLATER |
| Approved Compaction Report | 3/23/2023 | Approved | LANNY MERRICK |
| Bottom/Toe | 3/23/2023 | Not Ready for Inspection | LANNY MERRICK |
| Final | 3/23/2023 | Not Ready for Inspection | LANNY MERRICK |
| Rough | 3/23/2023 | Not Ready for Inspection | LANNY MERRICK |
| Bottom/Toe | 7/10/2023 | Partial Inspection | RUSSELL BONVOULOIR |
| Final | 7/10/2023 | Not Ready for Inspection | RUSSELL BONVOULOIR |
| Rough | 7/10/2023 | Partial Inspection | RUSSELL BONVOULOIR |
| Bottom/Toe | 7/25/2023 | Approved | RUSSELL BONVOULOIR |
| Final | 7/25/2023 | Permit Finaled | RUSSELL BONVOULOIR |
| Rough | 7/25/2023 | Approved | RUSSELL BONVOULOIR |